Frank Bode

Frank Bode

Auto-generated profile, based on publicly available information

Frank Bode

Medizinische Klinik II , Universitaetsklinikum Schleswig-Holstein , Campus Luebeck , Ratzeburger Allee 160 , 23560 Luebeck , Germany

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 March 2015 in EP Europace
Verified
Journal Article
Open access
PDF file
FBFrank Bode
Frank Bode
OBOliver Blanck
Oliver Blanck
MGMaximilian Gebhard
Maximilian Gebhard
PHPeter Hunold
Peter Hunold
MGMartin Grossherr
Martin Grossherr
DRDirk Rades
Dirk Rades
Electrical isolation of the pulmonary veins (PVs) has been established in clinical routine as a curative treatment for atrial fibrillation (AF). While catheter ablation carries procedural risks, radiosurgery might be able to non-invasively induce lesions at the PV ostia to block veno-atrial electrical conduction. This porcine feasibility and dose escalation study determined the effect of radiosurgery on electrophysiologic properties of the left atrial–PV junction. Eight adult Goettingen mini-pigs underwent electrophysiological voltage mapping in the left atrium and the upper right PV. Radiation was delivered with a conventional linear accelerator. A single homogeneous dose ranging from 22.5 to 40 Gy was applied circumferentially to the target vein antrum. Six months after radiosurgery, electrophysiological mapping was repeated and a histological examination performed. Voltage mapping consistently showed electrical potentials in the upper right PV at baseline. Pacing the target vein prompted atrial excitation, thus proving veno-atrial electrical conduction. After 6 months, radiation had reduced PV electrogram amplitudes. This was dose dependent with a mean interaction effect of −5.8%/Gy. Complete block of atrio-venous electrical conduction occurred after 40 Gy dose application. Histology revealed transmural scarring of the targeted PV musculature with doses >30 Gy. After 40 Gy, it spanned the entire circumference in accordance with pulmonary vein isolation. Pulmonary vein isolation to treat AF can be achieved by radiosurgery with a conventional linear accelerator. Yet, it requires a high radiation dose which might limit clinical applicability.

28 June 2012 in EP Europace
Verified
Journal Article
Open access
PDF file
FBFrank Bode
Frank Bode
FHFrank Himmel
Frank Himmel
MRMichael Reppel
Michael Reppel
KMKai Mortensen
Kai Mortensen
HSHeribert Schunkert
Heribert Schunkert
UWU. K. H. Wiegand
U. K. H. Wiegand
A considerable number of lead defects occurs during long-term cardioverter defibrillator therapy. Evidence-based strategies for the handling of chronically implanted, non-functional high-voltage (HV) leads are mandatory. Patient outcome after abandonment of HV leads was retrospectively compared with patient outcome following other lead revision strategies and following primary implantation. A total of 903 consecutive patients undergoing 997 implantable cardioverter defibrillator (ICD) implantations or lead revisions were followed for a mean period of 48.8 ± 37.8 months. One or more additional HV leads were placed in 60 patients. An additional pace/sense lead was implanted in 13 patients. Extraction and replacement of a dysfunctional HV lead was performed in 21 patients. The overall rate of complications including artefact sensing, ineffective defibrillation, symptomatic subclavian vein thrombosis, and other lead defects did not differ between patients with and without an additional HV lead (10.0 vs. 8.9%, P = 0.32). Survival without lead associated complications did not differ between groups. Results remained unchanged after correction for covariates. Abandoned HV leads did not increase the risk of ICD system-related complications in the majority of patients. Thus, a general lead extraction policy of dysfunctional HV leads cannot be advised in an average ICD population. Recommendations may not apply for young and physically active patients, in whom HV lead extraction must be considered.

9 January 2012 in The Journal of Clinical Hypertension
Verified
Journal Article
Closed access
FHFrank Himmel
Frank Himmel
FBFrank Bode
Frank Bode
KMKai Mortensen
Kai Mortensen
MRMichael Reppel
Michael Reppel
KFKlaas Franzen
Klaas Franzen
JWJoachim Weil
Joachim Weil

31 May 2012 in The Journal of Clinical Hypertension
Verified
Journal Article
Closed access
FHFrank Himmel
Frank Himmel
JWJoachim Weil
Joachim Weil
MRMichael Reppel
Michael Reppel
KMKai Mortensen
Kai Mortensen
KFKlaas Franzen
Klaas Franzen
FBFrank Bode
Frank Bode

30 August 2009 in Herzschrittmachertherapie + Elektrophysiologie
Verified
Journal Article
Closed access
PDF file
PBPd Dr. F. Bode
Pd Dr. F. Bode
FSF. Schütte
F. Schütte

7 March 2013 in PLOS ONE
Verified
Journal Article
Open access
PDF file
FBFrank Bode
Frank Bode
CBChristof Burgdorf
Christof Burgdorf
HSHeribert Schunkert
Heribert Schunkert
VKVolkhard Kurowski
Volkhard Kurowski
The etiologic basis of transient left ventricular apical ballooning, a novel cardiac syndrome, is not clear. Among the proposed pathomechanisms is coronary vasospasm. Long-term ST segment analysis may detect vasospastic episodes but has not been reported. 30 consecutive patients with transient left ventricular apical ballooning, left ventricular dysfunction and normal or near-normal coronary arteries were investigated. A 24-hour Holter ECG was obtained after emergency admission. ST segment analysis was performed automatically in 2 leads and confirmed by visual inspection. Criteria for an ischemic event were: 1. ST elevation or 2. horizontal or down-sloping ST segments ≥1 min duration and ≥100 µV J+80 point deviation corrected for baseline ST-deviation. Patients presented with ST segment elevation (n = 19) and/or T wave inversion (n = 20) on admission ECG. Ejection fraction was 50±12%. No transient ST elevations were observed during Holter ECG analysis. In 3 patients, 8 transient episodes of ST depression were recorded. Durations of episodes varied between 75s and 790s (mean 229s). Maximal ST deviation averaged −191±71 µV. Ischemic burden was −1 to −22 mVs (mean −8 mVs). 27 patients showed no ischemic events. ST segment analysis of 24 h Holter recordings revealed minor ischemic events in only 10% of patients with transient left ventricular apical ballooning. Overall, ST segment changes were not indicative of recurrent coronary spasm playing a major role in the genesis of transient left ventricular apical ballooning.