Alessandro Monesi

Alessandro Monesi

Auto-generated profile, based on publicly available information

Alessandro Monesi

Critical Care Nursing Master Course University of Bologna Bologna Italy

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 April 2022 in Anaesthesia Critical Care & Pain Medicine
Verified
Journal Article
Closed access
GIGuglielmo Imbriaco
Guglielmo Imbriaco
AMAlessandro Monesi
Alessandro Monesi
TSTimothy Spencer
Timothy Spencer

27 August 2020 in The Journal of Vascular Access
Verified
Journal Article
Closed access
PDF file
GIGuglielmo Imbriaco
Guglielmo Imbriaco
AMAlessandro Monesi
Alessandro Monesi
AGAimone Giugni
Aimone Giugni
NCNicola Cilloni
Nicola Cilloni
Radial artery cannulation (RAC) is a common procedure in Intensive Care Units (ICU); radial catheters for ICU patients require increased durability to collect blood samples and to guarantee continuous hemodynamic monitoring. Failure in catheter functionality needs catheter replacement, impacting on staff workload, costs, and patient safety and discomfort. prospective non-randomised cohort study on adult ICU patients describing intensivists and critical care nurses’ approach in radial artery catheterization. A sample of 103 radial artery cannulations was observed. Catheterization was performed blind in 71 patients (68.9%) and with ultrasound guidance (USG) in 32 (31.1%); majority of blind inserted RAC were at a distance between 0 and 3.9 cm from wrist joint (77.5%) while catheters inserted from 4 to 10 cm were mainly positioned with USG (84.4%). Radial catheters inserted with USG at a distance of 4 to 10 cm from wrist joint had an in-situ time double than those inserted blind (8.2 ± 7.5 vs 4.8 ± 7.3, p < 0.038). As recommended by current evidence and guidelines, USG represents a valuable support during arterial catheterization and is recommended in adult patients with clinical signs of shock, obese, swelling, and in the paediatric population. RAC in the forearm proximally, at a distance of at least 4 cm from wrist, could increase catheter durability and functionality for ICU patients. USG for cannulation in this forearm area is mandatory because of the deeper course of the radial artery.

2 June 2023 in Nursing in Critical Care
Verified
Journal Article
Open access
GIGuglielmo Imbriaco
Guglielmo Imbriaco
MCMartina Capitano
Martina Capitano
MRMargherita Rocchi
Margherita Rocchi
ASAglaia Suhan
Aglaia Suhan
ATAlice Tacci
Alice Tacci
BDBoaz Gedaliahu Samolsky Dekel
Boaz Gedaliahu Samolsky Dekel
Background: Noise pollution in intensive care units is a relevant problem, associated with psychological and physiological consequences for patients and healthcare staff. Sources of noise pollution include medical equipment, alarms, communication tools, staff activities, and conversations.Aims: To explore the cumulative effects of noise caused by an increasing number and type of medical devices in an intensive care setting on simulated patients with increasing clinical complexity. Secondly, to measure medical device alarms and nursing activities' sound levels, evaluating their role as potentially disruptive noises.Study Design: Observational simulation study (reported according to the STROBE checklist). Using an electronic sound meter, the sound levels of an intensive care room in seven simulated clinical scenarios were measured on a single day (09 March 2022), each featuring increasing numbers of devices, hypothetically corresponding to augmented patients' clinical complexity. Secondly, noise levels of medical device alarms and specific nursing activities performed at a distance of three meters from the sound meter were analysed.Results: The empty room's mean baseline noise level was 37.8 (±0.7) dBA; among the simulated scenarios, noise ranged between 45.3 (±1.0) and 53.5 (±1.5) dBA. Alarms ranged between 76.4 and 81.3 dBA, while nursing tasks (closing a drawer, opening a saline bag overwrap, or sterile packages) and speaking were all over 80 dBA. The noisiest activity was opening a sterile package (98 dBA).Conclusion: An increased number of medical devices, an expression of patients' higher clinical complexity, is not a significant cause of increased noise. Some specific nursing activities and conversations produce higher noise levels than medical devices and alarms. This study's findings suggest further research to assess the relationships between these factors and to encourage adequate noise reduction strategies.Relevance to Clinical Practice: Excessive noise level in the intensive care unit is a clinical issue that negatively affects patients' and healthcare providers' well‐being. The increase in baseline room noise from medical devices is generally limited. Typical nursing tasks and conversations produce higher noise levels than medical devices and alarms. These findings could be helpful to raise awareness among healthcare professionals to recognize noise sources. The noisiest components of the environment can be modified by staff behaviour, promoting noise reduction strategies and improving the critical care environment.

1 November 2009 in Current Organic Chemistry
Verified
Journal Article
Closed access
PDF file
TLTommaso Lanza
Tommaso Lanza
MMMatteo Minozzi
Matteo Minozzi
AMAlessandro Monesi
Alessandro Monesi
DNDANIELE NANNI
DANIELE NANNI
PSPiero Spagnolo
Piero Spagnolo
CCCinzia Chiappe
Cinzia Chiappe
The radical addition of thiols to double and triple carbon-carbon bonds was examined in typical ionic liquids ([bmim][PF6], [bmim][Tf2N], and [bmim][BF4]) under different temperature/initiator conditions (i.e. 80-100 °C / AIBNVAZO ®, r.t. / triethylborane, r.t. / AIBN / UV radiation, r.t. / photoinitiator / UV radiation). All the addition products were usually obtained with high efficiencies and very good recyclability of the ionic liquid. In some cases, small but significant differences were noticed by changing the reaction medium from benzene to a ionic liquid. The possibility of applying this procedure to click-chemistry reactions with thiols/alkenes of biological interest is also discussed.

1 April 2021 in The Journal of Emergency Medicine
Verified
Journal Article
Closed access
LGLorenzo Gamberini
Lorenzo Gamberini
GIGuglielmo Imbriaco
Guglielmo Imbriaco
AFAlfonso Flauto
Alfonso Flauto
AMAlessandro Monesi
Alessandro Monesi
CMCarlo Alberto Mazzoli
Carlo Alberto Mazzoli
GGGiovanni Gordini
Giovanni Gordini

29 October 2021 in Intensive and Critical Care Nursing
Verified
Journal Article
Closed access
GIGuglielmo Imbriaco
Guglielmo Imbriaco
AGArianna Gazzato
Arianna Gazzato
AMAlessandro Monesi
Alessandro Monesi
TSTommaso Scquizzato
Tommaso Scquizzato
FSFederico Semeraro
Federico Semeraro