Ferda Turgut

Ferda Turgut

Auto-generated profile, based on publicly available information

Ferda Turgut

Cukurova Universitesi

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 June 2023 in Acta Microbiologica Et Immunologica Hungarica
Verified
Journal Article
Closed access
PDF file
SCSeyda Cengiz
Seyda Cengiz
SOSıtkıcan Okur
Sıtkıcan Okur
COCihan Oz
Cihan Oz
FTFerda Turgut
Ferda Turgut
BGBurak Gumurcinler
Burak Gumurcinler
MAMehmet Adiguzel
Mehmet Adiguzel
Objectives: Methicillin-resistant Staphylococcus (MRS) has originated, spread extensively, and become a prominent source of bacterial infections in both human and animal.Methods: We report the prevalence, genetic diversity, and antimicrobial resistance pattern of Staphylococcus pseudintermedius and Staphylococcus aureus strains isolated from dogs and cats with eye discharges.Results: A total of 12 (6.0%) coagulase-positives staphylococci were identified as (6/200, 3%) S. aureus and (6/200, 3%) S. pseudintermedius. The phenotypic methicillin resistance of S. aureus and S. pseudintermedius were 50.0% (3/6) and 16.7% (1/6), respectively. None of the isolates showed biofilm formation in the microtiter plate assay. The highest resistance (50.0%) for S. pseudintermedius strains was detected against clindamycin and tetracycline. 67.0% of S. aureus isolates were resistant to penicillin-G. The PCR analysis conducted for detection of mecA gene indicated that only one S. aureus isolated from a cat was mecA gene positive. Phylogenetic analysis based on repetitive sequence-based PCR (rep-PCR) showed that all strains were typable and generated PCR products ranging from 800 bp to 4,400 bp. The lineages ST241 and the novel ST2361 in multi-locus sequence typing (MLST) analysis were detected in one methicillin-susceptible S. pseudintermedius and methicillin-resistant S. pseudintermedius of dogs, respectively. In addition, the lineages ST4155 and ST7217 of two methicillin-resistant S. aureus strains of cats were connected epidemiologically to previously reported cases.Conclusions: These results indicate epidemiologically related strains (ST241, ST4155, and ST7217) transferring between animals and humans. Therefore, the strategies to combat the widespread MRS should be based on collaboration between human and veterinary medicine under the One Health concept.

26 June 2023 in New Zealand Veterinary Journal
Verified
Journal Article
Closed access
SOSıtkıcan Okur
Sıtkıcan Okur
LYLE Yanmaz
LE Yanmaz
MSMg Senocak
Mg Senocak
UEU Ersöz
U Ersöz
AGA Gölgeli
A Gölgeli
YKY Kocaman
Y Kocaman
To compare intraocular pressure (IOP) measurements obtained in rabbits using rebound (TV) and applanation (TPV) tonometers with four different methods of physical restraint. A total of 20 New Zealand White rabbits (40 eyes) were included in this study. IOP readings were obtained from both eyes using the two different tonometers. The rabbits were placed on a table and restrained by wrapping in a cloth (Method I), by scruffing with rear support (Method II), by wrapping in a cloth and cupped in the hands (Method III), or by a box restrainer (Method IV). : The mean IOP measurement obtained by TPV was higher than that obtained with the TV for all handling methods. Mean differences (TV-TPV, in mm Hg) in IOP were -5.3 (95% Cl = -6.5 to -4.1) for Method 1, -4.7 (95% Cl = -6.2 to -3.29) for Method II, -4.9 (95% Cl = -6.2 to -3.7) for Method III and -7.6 (95% Cl = -9.2 to -5.9) for Method IV. Using the TV tonometer, mean IOP for Method IV was higher than for Method I (mean difference 2.1 (95% Cl = 1.1 - 3.1)), whereas using the TPV tonometer, mean IOP for Method IV was significantly higher than Method I, II, and III (mean differences (95% CI): 4.4 (2.6-5.9), 3.7 (2-5.3) and 3.8 (2-5.4), respectively).According to Bland-Altman plots, IOP readings for TPV tended to be higher than those for TV with all handling methods, but with a lack of agreement. The mean difference and 95% limits of agreement for the differences between TV and TPV were -5.4 mmHg (-12.5-1.9 mmHg), -4.7 mm Hg (-12.9-3.5 mmHg), -4.9 mmHg (-12-2.2 mmHg), and -7.5 mmHg (-17.4-2.3 mmHg), with Methods I, II, III, and IV, respectively. Comparing TV and TPV, only 7.5%, 12.5%, 27.5%, and 15% of IOP measurements from 20 rabbits were within the range considered clinically acceptable for IOP (± 2 mmHg) for Method I, II, III, and IV, respectively. In conclusion, the physical restraint method should be recorded when IOP is measured in rabbits, and TV and TPV tonometers cannot be used interchangeably (high bias and low proportion of measurements within ± 2 mmHg).

2 December 2024 in Erciyes Üniversitesi Veteriner Fakültesi Dergisi
Verified
Journal Article
Open access
PDF file
ABAyşe Gölgeli Bedir
Ayşe Gölgeli Bedir
LYLatif Emrah Yanmaz
Latif Emrah Yanmaz
SOSıtkıcan Okur
Sıtkıcan Okur
MŞMümin Gökhan Şenocak
Mümin Gökhan Şenocak
FTFerda Turgut
Ferda Turgut
BBBüşra Baykal
Büşra Baykal
In this retrospective investigation, the medical records of feline patients exhibiting ocular symptoms were comprehensively collected from Atatürk University, Veterinary Faculty, Animal Hospital over the period ranging from 2016 to 2023. A complete investigation was carried out a total of 427 cases with ocular disease observed in 310 cats. A statistical analysis was made to identify patterns associated with breed, age, gender, and anatomical localization. No evidence of gender predisposition to ocular diseases was found, while a higher incidence was noted in kittens aged 0-6 months, resulting in 57.4% of cases. In relation to breed predisposition, it was observed that ocular diseases demon-strated a higher prevalence among Mix breed and British shorthair cat breeds. The predominant conditions observed within patients were adnexa diseases, which represented 50.2% of cases, followed by nasolacrimal system disorders, which represented 27.9% of cases. In summary, it was shown that brachycephalic breeds presented a higher preva-lence of nasolacrimal disorders, whereas mix breed breeds indicated a higher incidence of ocular diseases.

21 December 2022 in Lasers in Medical Science
Verified
Journal Article
Closed access
PDF file
FTFerda Turgut
Ferda Turgut
LYLatif Emrah Yanmaz
Latif Emrah Yanmaz

10 January 2025 in Veterinary Medicine and Science
Verified
Journal Article
Open access
ABAyşe Gölgeli Bedir
Ayşe Gölgeli Bedir
LYLatif Emrah Yanmaz
Latif Emrah Yanmaz
SOSıtkıcan Okur
Sıtkıcan Okur
MŞMümin Gökhan Şenocak
Mümin Gökhan Şenocak
FTFerda Turgut
Ferda Turgut
BBBüşra Baykal
Büşra Baykal
Objectives: Vomiting is frequently observed in cats after dexmedetomidine administration. This study aimed to compare the efficacy of different antiemetics in preventing vomiting in cats after dexmedetomidine administration.Methods: Sixty‐four cats were randomly allocated to receive saline solution (0.9% NaCl, 0.1 mL/kg, SC), maropitant (1 mg/kg, SC), ondansetron (0.22 mg/kg, IM) or metoclopramide (1 mg/kg, IM) 30 min before the intramuscular administration of dexmedetomidine (25 µg/kg). Duration of vomiting, severity of vomiting and nausea signs (sialorrhoea, lip licking, retching and vomiting) was recorded for 30 min after dexmedetomidine administration.Results: The duration and severity of vomiting were significantly reduced in groups that received maropitant, ondansetron or metoclopramide compared to the saline group. Although differences were observed in retching and vomiting between the saline and other groups (p < 0.001), there were no significant differences in sialorrhoea or lip licking (p = 0.34 and p = 0.12, respectively).Conclusions: Maropitant, ondansetron and metoclopramide were found to significantly reduce retching and vomiting compared to the control group. In conclusion, no significant difference was found among maropitant, ondansetron and metoclopramide groups in the prevention of dexmedetomidine‐induced vomiting in cats.

7 November 2024 in Van Veterinary Journal
Verified
Journal Article
Open access
SOSıtkıcan Okur
Sıtkıcan Okur
LYLatif Emrah Yanmaz
Latif Emrah Yanmaz
ÖOÖmer Tarık Orhun
Ömer Tarık Orhun
YKYakup Kocaman
Yakup Kocaman
ABAyşe Gölgeli Bedir
Ayşe Gölgeli Bedir
UEUgur Ersoz
Ugur Ersoz
The assessment of intraocular pressure (IOP) holds significant importance in ophthalmology as a crucial diagnostic tool for various ocular disorders. In the realm of comparative ophthalmology research, investigating ocular examination in sheep, particularly Merinos, is of considerable interest. This study aimed to evaluate the agreement between rebound (TonoVet®, TV) and applanation (Tono-Pen Vet™, TPV) tonometers in measuring IOP in healthy Merino sheep. 155 healthy Merinos (80 males, 75 females) with a mean weight of 54.4 ± 8.7 kg, aged 24 ± 6 months, were included in the study. IOP was measured between 9:00 and 11:00 am using both the rebound and applanation tonometers. The rebound tonometer was utilized first, followed by the applanation tonometer. A total of 620 readings (310 readings per eye) were obtained from the two devices. No statistical differences were noted between the mean IOP measurements of the right and left eyes for both tonometers (P > 0.05). However, there was a significant difference in the mean IOP measurements between the TV (11.8 ± 2.3 mmHg) and the TPV (13.9 ± 2.9 mmHg) tonometers (P < 0.001). The concordance correlation coefficient indicated weak agreement strength (ρc = 0.319, CI 95% = -0.169 to 0.455) between the TV and TPV. The mean difference in bias and the 95% limits of agreement for the differences between TV and TPV were -2.1 mmHg (-9.0 to 3.5 mmHg). The regression equation derived from a Bland-Altman plot, describing the relationship between the two tonometers, was Y = 1.43 - 0.33X (Y = TV and X = TPV). In conclusion, the TPV measured higher IOP values compared to the TV, and due to the significant bias and limits of agreement, the two tonometers should not be used interchangeably for IOP measurement in Merino sheep.