The effects of adrenaline on cerebral blood vessels during cardiopulmonary resuscitation (CPR) are not well understood. We developed an extracorporeal CPR model that maintains constant low systemic blood flow while allowing adrenaline-associated effects on cerebral vasculature to be assessed at different mean arterial pressure (MAP) levels independently of the effects on systemic blood flow. After eight minutes of cardiac arrest, low-flow extracorporeal life support (ECLS) (30 ml/kg/min) was started in fourteen pigs. After ten minutes, continuous adrenaline administration was started to achieve MAP values of 40 (n = 7) or 60 mmHg (n = 7). Measurements included intracranial pressure (ICP), cerebral perfusion pressure (CePP), laser-Doppler-derived regional cerebral blood flow (CBF), cerebral regional oxygen saturation (rSO2), brain tissue oxygen tension (PbtO2) and extracellular cerebral metabolites assessed by cerebral microdialysis. During ECLS without adrenaline, regional CBF increased by only 5% (25th to 75th percentile: -3 to 14; p = 0.2642) and PbtO2 by 6% (0-15; p = 0.0073) despite a significant increase in MAP to 28 mmHg (25-30; p < 0.0001) and CePP to 10 mmHg (8-13; p < 0.0001). Accordingly, cerebral microdialysis parameters showed a profound hypoxic-ischemic pattern. Adrenaline administration significantly improved regional CBF to 29 ± 14% (p = 0.0098) and 61 ± 25% (p < 0.001) and PbtO2 to 15 ± 11% and 130 ± 82% (both p < 0.001) of baseline in the MAP 40 mmHg and MAP 60 mmHg groups, respectively. Importantly, MAP of 60 mmHg was associated with metabolic improvement. This study shows that adrenaline administration during constant low systemic blood flow increases CePP, regional CBF, cerebral oxygenation and cerebral metabolism.
Background: Flow-controlled ventilation (FCV) is a novel ventilation method increasingly being used clinically, particularly during the current COVID-19 pandemic. However, the continuous flow pattern in FCV during inspiration and expiration has a significant impact on respiratory parameters and ventilatory settings compared to conventional ventilation modes. In addition, the constant flow combined with direct intratracheal pressure measurement allows determination of dynamic compliance and ventilation settings can be adjusted accordingly, reflecting a personalized ventilation approach. Case presentation: A 50-year old women with confirmed SARS-CoV-2 infection suffering from acute respiratory distress syndrome (ARDS) was admitted to a tertiary medical center. Initial ventilation occurred with best standard of care pressure-controlled ventilation (PCV) and was then switched to FCV, by adopting PCV ventilator settings. This led to an increase in oxygenation by 30 %. Subsequently, to reduce invasiveness of mechanical ventilation, FCV was individualized by dynamic compliance guided adjustment of both, positive end-expiratory pressure and peak pressure; this intervention reduced driving pressure from 18 to 12 cm H2O. However, after several hours, compliance further deteriorated which resulted in a tidal volume of only 4.7 ml/kg. Conclusions: An individualized FCV approach increased oxygenation parameters in a patient suffering from severe COVID-19 related ARDS. Direct intratracheal pressure measurements allow for determination of dynamic compliance and thus optimization of ventilator settings, thereby reducing applied and dissipated energy. However, although desirable, this personalized ventilation strategy may reach its limits when lung function is so severely impaired that patient’s oxygenation has to be ensured at the expense of lung protective ventilation concepts.
Article: Short time effects of compliance guided flow-controlled ventilation versus standard of care pressure-controlled ventilation - a prospective porcine trial - Minerva Anestesiologica 2023 Feb 17 - Minerva Medica - Journals
This study examined the effects of a continuous (flow-controlled ventilation, FCV) vs. decelerating (pressure-controlled ventilation, PCV) gas flow pattern during mechanical ventilation. It was shown that FCV necessitates a lower alveolar pressure amplitude leading to reduced applied tidal volumes and consequently minute volume. Notwithstanding these differences, CO2-removal as well as oxygenation was not inferior in FCV compared with PCV, which is suggestive of improved gas exchange efficiency at a continuous gas flow pattern.
Commentary: Flow-controlled ventilation maintains gas exchange and lung aeration in a pediatric model of healthy and injured lungs: a randomized cross-over experimental study