Tomoaki Nagaoka

Tomoaki Nagaoka

Auto-generated profile, based on publicly available information

Tomoaki Nagaoka

National Institute of Information and Communications Technology, Tokyo, Japan

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 October 2007 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
TNTomoaki Nagaoka
Tomoaki Nagaoka
TTToshihiro Togashi
Toshihiro Togashi
KSKazuyuki Saito
Kazuyuki Saito
MTMasaharu Takahashi
Masaharu Takahashi
KIKoichi Ito
Koichi Ito
SWSoichi Watanabe
Soichi Watanabe
The numerical dosimetry of pregnant women is an important issue in electromagnetic-field safety. However, an anatomically realistic whole-body pregnant-woman model for electromagnetic dosimetry has not been developed. Therefore, we have developed a high-resolution whole-body model of pregnant women. A new fetus model including inherent tissues of pregnant women was constructed on the basis of abdominal magnetic resonance imaging data of a 26-week-pregnant woman. The whole-body pregnant-woman model was developed by combining the fetus model and a nonpregnant-woman model that was developed previously. The developed model consists of about 7 million cubical voxels of 2 mm size and is segmented into 56 tissues and organs. This pregnant-woman model is the first completely anatomically realistic voxel model that includes a realistic fetus model and enables a numerical simulation of electromagnetic dosimetry up to the gigahertz band. In this paper, we also present the basic specific absorption rate characteristics of the pregnant-woman model exposed to vertically and horizontally polarized electromagnetic waves from 10 MHz to 2 GHz.

7 November 2008 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
TNTomoaki Nagaoka
Tomoaki Nagaoka
EKEtsuo Kunieda
Etsuo Kunieda
SWSoichi Watanabe
Soichi Watanabe
The development of high-resolution anatomical voxel models of children is difficult given, inter alia, the ethical limitations on subjecting children to medical imaging. We instead used an existing voxel model of a Japanese adult and three-dimensional deformation to develop three voxel models that match the average body proportions of Japanese children at 3, 5 and 7 years old. The adult model was deformed to match the proportions of a child by using the measured dimensions of various body parts of children at 3, 5 and 7 years old and a free-form deformation technique. The three developed models represent average-size Japanese children of the respective ages. They consist of cubic voxels (2 mm on each side) and are segmented into 51 tissues and organs. We calculated the whole-body-averaged specific absorption rates (WBA-SARs) and tissue-averaged SARs for the child models for exposures to plane waves from 30 MHz to 3 GHz; these results were then compared with those for scaled down adult models. We also determined the incident electric-field strength required to produce the exposure equivalent to the ICNIRP basic restriction for general public exposure, i.e., a WBA-SAR of 0.08 W kg(-1).

15 April 2009 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
PDF file
PDPeter J Dimbylow
Peter J Dimbylow
TNTomoaki Nagaoka
Tomoaki Nagaoka
XXX George Xu
X George Xu
This paper compares the foetal SAR in the HPA hybrid mathematical phantoms with the 26-week foetal model developed at the National Institute of Information and Communications Technology, Tokyo, and the set of 13-, 26- and 38-week boundary representation models produced at Rensselaer Polytechnic Institute. FDTD calculations are performed at a resolution of 2 mm for a plane wave with a vertically aligned electric field incident upon the body from the front, back and two sides from 20 MHz to 3 GHz under isolated conditions. The external electric field values required to produce the ICNIRP public exposure localized restriction of 2 W kg(-1) when averaged over 10 g of the foetus are compared with the ICNIRP reference levels.

1 August 2010
Verified
Conference Paper
Closed access
TNTomoaki Nagaoka
Tomoaki Nagaoka
SWSoichi Watanabe
Soichi Watanabe
Numerical simulations with the numerical human model using the finite-difference time domain (FDTD) method have recently been performed frequently in a number of fields in biomedical engineering. However, the FDTD calculation runs too slowly. We focus, therefore, on general purpose programming on the graphics processing unit (GPGPU). The three-dimensional FDTD method was implemented on the GPU using Compute Unified Device Architecture (CUDA). In this study, we used the NVIDIA Tesla C1060 as a GPGPU board. The performance of the GPU is evaluated in comparison with the performance of a conventional CPU and a vector supercomputer. The results indicate that three-dimensional FDTD calculations using a GPU can significantly reduce run time in comparison with that using a conventional CPU, even a native GPU implementation of the three-dimensional FDTD method, while the GPU/CPU speed ratio varies with the calculation domain and thread block size.

12 September 2019 in IEEE Access
Verified
Journal Article
Open access
TNTomoaki Nagaoka
Tomoaki Nagaoka
SWSoichi Watanabe
Soichi Watanabe
New child voxel models that are adjusted to the International Commission on Radiological Protection (ICRP)’s reference values (1-, 5-and 10-yr-old children) have been developed. The whole-body averaged specific absorption ratios (WBA-SARs) of these child voxel models were calculated for the whole-body exposure conditions with the E-polarization and H-polarization plane wave incidence from 10 MHz to 6 GHz. The WBA-SARs are 40% to 50% higher for the child voxel models than for adult voxel models adjusted to the ICRP’s reference values (NORMAN and NAOMI). The WBA-SARs of the child voxel models exceed the basic restriction by at most 20% or 0.08 W/kg for the general environment when the incident power density is set to the reference level at each frequency of the ICNIRP’s RF safety guidelines.

1 August 2011
Verified
Conference Paper
Closed access
TNTomoaki Nagaoka
Tomoaki Nagaoka
SWSoichi Watanabe
Soichi Watanabe
Numerical simulation with a numerical human model using the finite-difference time domain (FDTD) method has recently been performed in a number of fields in biomedical engineering. To improve the method's calculation speed and realize large-scale computing with the numerical human model, we adapt three-dimensional FDTD code to a multi-GPU environment using Compute Unified Device Architecture (CUDA). In this study, we used NVIDIA Tesla C2070 as GPGPU boards. The performance of multi-GPU is evaluated in comparison with that of a single GPU and vector supercomputer. The calculation speed with four GPUs was approximately 3.5 times faster than with a single GPU, and was slightly (approx. 1.3 times) slower than with the supercomputer. Calculation speed of the three-dimensional FDTD method using GPUs can significantly improve with an expanding number of GPUs.