Kaj Lindecrantz

Kaj Lindecrantz

Auto-generated profile, based on publicly available information

Kaj Lindecrantz

KTH Royal Institute of Technology

Research Focus & Metrics

Academic Career Length

44Years (1983-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 February 2013 in BMC Medical Informatics and Decision Making
Verified
Journal Article
Open access
PDF file
AGAnna Gund
Anna Gund
BSBengt Arne Sjöqvist
Bengt Arne Sjöqvist
HWHelena Wigert
Helena Wigert
EHElisabet Hentz
Elisabet Hentz
KLKaj Lindecrantz
Kaj Lindecrantz
KBKristina Bry
Kristina Bry
Background: One area where the use of information and communication technology (ICT), or eHealth, could be developed is the home health care of premature infants. The aim of this randomized controlled study was to investigate whether the use of video conferencing or a web application improves parents’ satisfaction in taking care of a premature infant at home and decreases the need of home visits. In addition, nurses’ attitudes regarding the use of these tools were examined. Method: Thirty-four families were randomized to one of three groups before their premature infant was discharged from the hospital to home health care: a control group receiving standard home health care (13 families); a web group receiving home health care supplemented with the use of a web application (12 families); a video group with home health care supplemented with video conferencing using Skype (9 families). Families and nursing staff answered questionnaires about the usefulness of ICT. In addition, semi-structured interviews were conducted with 16 families. Results: All the parents in the web group found the web application easy to use. 83% of the families thought it was good to have access to their child’s data through the application. All the families in the video group found Skype easy to use and were satisfied with the video calls. 88% of the families thought that video calls were better than ordinary phone calls. 33% of the families in the web group and 75% of those in the video group thought the need for home visits was decreased by the web application or Skype. 50% of the families in the web group and 100% of those in the video group thought the web application or the video calls had helped them feel more confident in caring for their child. Most of the nurses were motivated to use ICT but some were reluctant and avoided using the web application and video conferencing. Conclusion: The families were satisfied with both the web application and video conferencing. The families readily embraced the use of ICT, whereas motivating some of the nurses to accept and use ICT was a major challenge.

14 January 2010 in Journal of Neural Engineering
Verified
Journal Article
Closed access
JLJohan Löfhede
Johan Löfhede
MTMagnus Thordstein
Magnus Thordstein
NLNils Löfgren
Nils Löfgren
AFAnders Flisberg
Anders Flisberg
Manuel Rosa-ZureraManuel Rosa-Zurera
Manuel Rosa-Zurera
KLKaj Lindecrantz
Kaj Lindecrantz
The overall aim of our research is to develop methods for a monitoring system to be used at neonatal intensive care units. When monitoring a baby, a range of different types of background activity needs to be considered. In this work, we have developed a scheme for automatic classification of background EEG activity in newborn babies. EEG from six full-term babies who were displaying a burst suppression pattern while suffering from the after-effects of asphyxia during birth was included along with EEG from 20 full-term healthy newborn babies. The signals from the healthy babies were divided into four behavioural states: active awake, quiet awake, active sleep and quiet sleep. By using a number of features extracted from the EEG together with Fisher's linear discriminant classifier we have managed to achieve 100% correct classification when separating burst suppression EEG from all four healthy EEG types and 93% true positive classification when separating quiet sleep from the other types. The other three sleep stages could not be classified. When the pathological burst suppression pattern was detected, the analysis was taken one step further and the signal was segmented into burst and suppression, allowing clinically relevant parameters such as suppression length and burst suppression ratio to be calculated. The segmentation of the burst suppression EEG works well, with a probability of error around 4%.

31 July 2006 in NeuroReport
Verified
Journal Article
Closed access
MTMagnus Thordstein
Magnus Thordstein
NLNils Löfgren
Nils Löfgren
AFAnders Flisberg
Anders Flisberg
KLKaj Lindecrantz
Kaj Lindecrantz
IKIngemar Kjellmer
Ingemar Kjellmer
Cerebral cortical activity in healthy, full-term human neonates (10 boys and 10 girls) was evaluated using spectral estimation of electroencephalogram frequency content with new equipment and analysis technique allowing the assessment of the lowest frequencies (i.e. infraslow waves). The activity was analysed under quiet sleep and active wakefulness taking sex into consideration. During sleep, the mean amount of infraslow activity was 27% larger in boys, whereas during wakefulness the average amount of higher frequencies was 17% larger in girls. Both these differences indicate an earlier maturation of cortical function in girls than in boys.

22 May 2014 in Physiological Measurement
Verified
Journal Article
Closed access
RBRuben Buendia
Ruben Buendia
FSFernando Seoane
Fernando Seoane
IBI Bosaeus
I Bosaeus
Roberto Gil PitaRoberto Gil Pita
Roberto Gil Pita
GJG Johannsson
G Johannsson
KLK Lindecrantz
K Lindecrantz
The estimation of body fluids is a useful and common practice for assessment of disease status and therapy outcomes. Electrical bioimpedance spectroscopy (EBIS) methods are noninvasive, inexpensive and efficient alternatives for determination of body fluids. One of the main source of errors in EBIS measurements in the estimation of body fluids is capacitive coupling. In this paper an analysis of capacitive coupling in EBIS measurements was performed and the robustness of the different immittance spectra against it tested. On simulations the conductance (G) spectrum presented the smallest overall error, among all immittance spectra, in the estimation of the impedance parameters used to estimate body fluids. Afterwards the frequency range of 10-500 kHz showed to be the most robust band of the G spectrum. The accuracy of body fluid estimations from the resulting parameters that utilized G spectrum and parameters provided by the measuring device were tested on EBIS clinical measurements from growth hormone replacement therapy patients against estimations performed with dilution methods. Regarding extracellular fluid, the correlation between each EBIS method and dilution was 0.93 with limits of agreement of 1.06 ± 2.95 l for the device, 1.10 ± 2.94 l for G [10-500 kHz] and 1.04 ± 2.94 l for G [5-1000 kHz]. Regarding intracellular fluid, the correlation between dilution and the device was 0.91, same as for G [10-500 kHz] and 0.92 for G [5-1000 kHz]. Limits of agreement were 0.12 ± 4.46 l for the device, 0.09 ± 4.45 for G [10-500 kHz] and 0.04 ± 4.58 for G [5-1000 kHz]. Such close results between the EBIS methods validate the proposed approach of using G spectrum for initial Cole characterization and posterior clinical estimation of body fluids status.

1 November 1989 in Clinical Physics and Physiological Measurement
Verified
Journal Article
Closed access
PDF file
KRK G Rosen
K G Rosen
KLK Lindecrantz
K Lindecrantz
Waveform analysis of the fetal ECG for fetal surveillance is regaining widespread interest. This paper presents our present knowledge on ST waveform analysis during human labour. A unipolar scalp lead with the maternal thigh as reference makes it possible to identify the T wave and at the same time decrease signal noise. The development of an ECG analyser (STAN) has enabled us to collect 201 ECG recordings during labour on which ST analysis could be undertaken. The data indicate that waveform analysis of the fetal ECG improves fetal surveillance during labour.

1 January 1990 in Journal of Perinatal Medicine
Verified
Journal Article
Closed access
SASabaratnam Arulkumaran
Sabaratnam Arulkumaran
HLHåkan Lilja
Håkan Lilja
KLKaj Lindecrantz
Kaj Lindecrantz
SRShanmuga S. Ratnam
Shanmuga S. Ratnam
ATArumugam S. Thavarasah
Arumugam S. Thavarasah
KRKarl G. Rosén
Karl G. Rosén
Fetal heart rate (FHR) and fetal electrocardiogram (ECG) recordings were obtained from a scalp electrode with maternal thigh as reference and used for ST waveform analysis in 201 patients in labour. Nearly 45% had suspicious or abnormal FHR traces whilst only 27% had T/QRS ratio greater than 0.25 (mean +/- 2 SD). A normal T/QRS ratio identified 99.3% of fetuses with normal buffering capacity in cord artery blood. Of 13 infants with a cord artery blood pH less than 7.15, standard bicarbonate was less than 15.0 mmol/l in five who had an average T/QRS ratio less than 0.25 throughout labour. Of the eight with respiratory acidosis, five had an increase in T/QRS ratio greater than 0.25 for longer than 20 minutes prior to delivery, in two the ratio increased during the last few minutes and one had no change (pH 7.14). Persistent elevation of T/QRS in the first stage of labour identified those with decrease in buffer capacity in cord arterial blood (sensitivity of 94.1%). Acute hypoxia was recognized by the rapid rise in T/QRS. The specificity of T/QRS to identify fetuses at risk increased by combining the ST waveform analysis with FHR changes.