15 June 2017 in Nuclear Fusion
16 July 2014 in Physical Review C
Results of decay spectroscopy on nuclei in the vicinity of the doubly magic are presented. The measurements were performed with a time projection chamber with optical readout which records tracks of ions and protons in the gaseous volume. Six decays of , including four events of two-proton ground-state radioactivity, were recorded. An advanced reconstruction procedure yielded the decay energy for of MeV. In addition, the energy spectra of -delayed protons emitted in the decays of and , as well as half-lives and branching ratios, were determined. The results were found to be consistent with the previous measurements made with Si detectors. A new proton line in the decay of corresponding to the decay energy of 760 keV is reported. The first evidence for the decay of , based on one clear event, is shown.
27 June 2011 in Physical Review C
The decay of the extremely neutron-deficient was studied by means of an imaging time-projection chamber, which allowed the recording of tracks of charged particles. The decays of six atoms were observed. Four of them clearly correspond to two-proton radioactivity, providing the first direct evidence for this decay mode in . Two decays represent -delayed proton emission. The half-life of is determined to be ms.
22 July 2017 in Nukleonika
LaBr3:Ce,CeBr3 and GAGG:Ce scintillators were investigated and the determined characteristics were compared with those obtained for the well-known and widely used CsI:Tl and NaI:Tl crystals. All the detectors were of the same size of 10 × 10 × 5 mm3. The aim of this test study was to single out scintillation detectors most suitable for γ-ray spectrometry and γ-ray emission radial profile measurements in high-temperature plasma experiments. Decay time, energy resolution, non-proportionality and full energy peak detection efficiency ere measured for γ-ray energies up to 1770 keV. Due to their good energy resolution, short decay time and high detection efficiency for MeV gamma rays, LaBr3:Ce and CeBr3 scintillators are proposed as the best candidates for use especially under conditions of high count rates, which are expected in the forthcoming DT experiments.
23 August 2016 in Review of Scientific Instruments
In this work, we describe the solution developed by the gamma ray camera upgrade enhancement project to improve the spectroscopic properties of the existing JET γ-ray camera. Aim of the project is to enable gamma-ray spectroscopy in JET deuterium-tritium plasmas. A dedicated pilot spectrometer based on a LaBr3 crystal coupled to a silicon photo-multiplier has been developed. A proper pole zero cancellation network able to shorten the output signal to a length of 120 ns has been implemented allowing for spectroscopy at MHz count rates. The system has been characterized in the laboratory and shows an energy resolution of 5.5% at Eγ = 0.662 MeV, which extrapolates favorably in the energy range of interest for gamma-ray emission from fast ions in fusion plasmas.
9 May 2016 in Physica Scripta
In forthcoming deuterium-tritium (DT) experiments on JET a significant population of alpha-particles will be produced. For operating alpha-particle diagnostics at high DT neutron fluxes, specific improvements have to be made. Proposed new detectors for gamma-ray measurements will be based on CeBr 3 and LaBr 3 :Ce scintillators. They are characterized by a good energy resolution, a relatively high detection efficiency for a few MeV gamma-rays and a fast response time. An overview of scintillator parameters is presented. A description of the properties of photodetectors is given to indicate optimal setups. Results of measurements, using gamma-ray sources with energies up to a few MeV, are discussed with relation to the DT campaign requirements.