1 July 2020 in World Neurosurgery
11 March 2021 in International Journal of Computer Assisted Radiology and Surgery
1 January 2021 in Neurologia medico-chirurgica
Cone beam computed tomography (CBCT) images are degraded by artifacts due to endovascular implants. We evaluated the use of streak metal artifact reduction technique (SMART) in non-contrast CBCT images after endovascular neurosurgery obtained from 148 patients (125 with aneurysm and 23 with dural arteriovenous fistula [dAVF]). Three neurosurgeons evaluated the cistern and brain surface visibility in CBCT images with and without SMART correction based on a 4-point scale (1, excellent; 2, good; 3, limited; and 4, insufficient). Significant improvement in visibility was achieved when the median scores improved from 4 or 3 to 2 or 1 or from 2 to 1. Metal artifact reduction in adjacent slices without metal and new artifacts after SMART correction was also examined. A significant improvement was achieved regarding the visibility of the cistern in 90 (60.8%) images and of the brain surface in 108 (73.0%) images. Metal size (cistern: odds ratio [OR], 0.91 per 1 mm increase; 95% confidence interval [CI], 0.83–0.99), irregular metal shape (cistern: OR, 0.18; 95% CI, 0.05–0.60 and brain surface: OR, 0.15; 95% CI, 0.05–0.45), and infratentorial lesions (cistern: OR, 0.37; 95% CI, 0.14–0.96 and brain surface: OR, 0.30; 95% CI, 0.11–0.80) were negatively correlated with improved visibility. Metal artifact reduction in adjacent slices without metal was obtained in 25.6% and 34.8% of images with aneurysm and dAVF, respectively. New artifacts after SMART correction were found in 4.8% and 13.0% of images with aneurysm and dAVF, respectively. SMART is especially effective for supratentorial small aneurysms.
15 September 2022 in NMC Case Report Journal
In this article, we report a case wherein a brain tumor was suspected based on computed tomography and magnetic resonance imaging findings. We made an initial diagnosis of malignant brain tumor based on methionine-positron emission tomography (PET) findings, but the correct diagnosis was dural arteriovenous fistula (DAVF). The patient was a 45-year-old man with DAVF who developed headache. Methionine-PET imaging showed high methionine uptake in the lesion. Although the tumor was strongly suspected from the findings of methionine-PET, the diagnosis of DAVF could be made correctly only by interpreting digital subtraction angiography and computed tomographic angiography. The findings of methionine-PET, which is considered useful in the diagnosis and denial of brain tumors, made the diagnosis of DAVF more difficult. The increased uptake of methionine-PET in DAVF is an important finding because, to our knowledge, this study is the first to report such finding. The results of this study might be useful for differential diagnoses when the diagnosis is uncertain.
26 June 2023 in NMC Case Report Journal
Intracranial aneurysms (IA) in infants are reportedly rare at 0.5% to 4.5% of all aneurysms. Furthermore, subarachnoid hemorrhage in infants younger than three months are even rarer as it has been reported in approximately 20 cases only till date.A 3-month-old infant with seizures and impaired consciousness was admitted to our hospital. Three-dimensional computed tomography angiography (3D-CTA) revealed a dissecting aneurysm with a maximum diameter of 13 mm in the right M2. Internal trapping using detachable coil were successfully performed, following which he was discharged without significant neurological deficit after one month of onset. Thus, we have reported a rare case of a large ruptured dissecting IA in a 3-month-old infant, in the right middle cerebral artery (MCA), successfully treated with an endovascular therapy, along with a literature review.
1 February 2021 in World Neurosurgery