Mehmet Selim Kocabora

Mehmet Selim Kocabora

Auto-generated profile, based on publicly available information

Mehmet Selim Kocabora

Istanbul Medipol University

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2019 in Medical Journal of Bakırkoy
Verified
Journal Article
Closed access
CTCafer Tanrıverdi
Cafer Tanrıverdi
SESevil Karaman Erdur
Sevil Karaman Erdur
MKMehmet Selim Kocabora
Mehmet Selim Kocabora
SYSultan Yıldız
Sultan Yıldız
LHLütfü Hanoğlu
Lütfü Hanoğlu

14 September 2018 in Ege Tıp Dergisi
Verified
Journal Article
Open access
PDF file
SESevil Karaman Erdur
Sevil Karaman Erdur
FDFunda Di̇kkaya
Funda Di̇kkaya
GDGoktug Demirci
Goktug Demirci
MÖMustafa Özsütçü
Mustafa Özsütçü
RARUKIYE AYDIN Aydin
RUKIYE AYDIN Aydin
MKMehmet Selim Kocabora
Mehmet Selim Kocabora
Aim: To evaluate anterior segment parameters in the eyes of adults with anisohypermetropic amblyopia using the Sirius topography device.Materials and Methods: Forty-eight patients with anisohypermetropic amblyopia were prospectively evaluated along with a control group of 45 healthy patients. All patients were examined with the Sirius topography system under cycloplegic and non-cycloplegic conditions. The anterior and posterior mean keratometry values, central corneal thickness (CCT), anterior chamber depth (ACD), corneal volume (CV), and anterior chamber volume (ACV) measurements were compared among groups.Results: No significant difference was found in the anterior and posterior mean keratometry values, CCT, ACD, CV, and ACV measurements between amblyopic, fellow, and control eyes under cycloplegic and non-cycloplegic conditions (p>0.05).Conclusion: This study shows that the anterior segment parameters measured by the Sirius topography device among amblyopic, fellow, and control eyes do not differ under both cycloplegic and non-cycloplegic conditions.

29 May 2021 in Batı Karadeniz Tıp Dergisi
Verified
Journal Article
Closed access
PDF file
FDFunda Di̇kkaya
Funda Di̇kkaya
MKMehmet Kocabora
Mehmet Kocabora
CYCemil Yilmazli
Cemil Yilmazli
SESevil Karaman Erdur
Sevil Karaman Erdur
AAArzu Aşici
Arzu Aşici
Purpose: To evaluate the intraocular pressure (IOP) lowering and safety profiles of the Xen45 Gel Stent implantation with preoperative Mitomycin C injection during a 6 months follow-up in patients with primary open-angle glaucoma (POAG). Materials and Methods: Records of fourteen eyes of 13 POAG patients who underwent surgery with XEN45 Gel Stent combined with phacoemulsification were evaluated retrospectively. IOP changes, all complications and additional procedures during follow-up period were evaluated. Primary outcome measure was IOP, and the IOP target for complete success was defined as a postoperative IOP drop of more than 20% from preoperative baseline and IOP≥6 and ≤21 at 6 months without any glaucoma medications and qualified success was defined as a postoperative IOP reduction of more than 20% and IOP≥6 and ≤21 at 6 months with or without medications. Results: Mean preoperative medicated IOP was 28.4 ± 2.7 mmHg with a mean of 2.6 ± 0.6 topical anti-glaucoma molecules. After 6 month follow-up period, mean IOP decreased to 17.8 ± 1.5 mmHg (mean IOP reduction of 37%) on 0.4 ± 1.1 antiglaucoma molecules. The complete success rate after 6 months was achieved in 42.8 % and qualified success in 85.7. Totally only 2 (14.2 %) patients required additional procedure (1 needling and 1 trabeculectomy). Conclusions: The study showed that the XEN45 Gel Stent implantation combined with phaco-cataract surgery is an effective surgical method in POAG in case of uncontrolled IOP with a favorable safety profile and low complication rate.