Weifeng Zhu

Weifeng Zhu

Auto-generated profile, based on publicly available information

Weifeng Zhu

Department of Internal Medicine/Rheumatology, University of Texas Health Science Center at Houston McGovern Medical School, Houston, USA

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 August 2024 in Radiation Measurements
Verified
Journal Article
Closed access
WZWeifeng Zhu
Weifeng Zhu
JWJinjie Wu
Jinjie Wu
RZRui Zhao
Rui Zhao
XTXianqiang Tang
Xianqiang Tang
MLMengyu Li
Mengyu Li

29 August 2018 in The Open Rheumatology Journal
Verified
Journal Article
Open access
PDF file
YDYan Deng
Yan Deng
WZWeifeng Zhu
Weifeng Zhu
XZXiaodong Zhou
Xiaodong Zhou
Immune Regulatory Genes Are Major Genetic Factors to Behcet Disease: Systematic Review

1 July 2015
Verified
Conference Paper
Closed access
ZWZhu Weifeng
Zhu Weifeng
ZSZhang Shibin
Zhang Shibin
DXDai Xiu
Dai Xiu
A broadband microwave sampler applied to vector network analyzer is presented in this paper. In vector network analyzer, the sampler is an important part of phase-locked system and S parameters measurement system. It converts high frequency microwave signals into low frequency signals, while amplitude and phase information of microwave signals are kept. Firstly, the principle of microwave sampler is introduced. Then realization circuits including RF matching & amplifying circuit, sampling pulse processing circuit, switch-sampling circuit and IF filter & amplifying circuit are described. Finally, measurement results of the broadband microwave sampler are given. The measurement results show that the sampler works from 30 kHz to 6 GHz, return loss of RF port could reach -10dB, and frequency conversion loss is better than -9 dB (IF amplifier with 15dB gain is included in test process). In the future, Low-frequency capacitor can be substituted by high-frequency multilayer capacitors to improve RF port's return loss characteristic. This sampler could fit well for VNA's application requirements.

1 October 2015
Verified
Conference Paper
Closed access
QWQi Wang
Qi Wang
YNYuemin Ning
Yuemin Ning
YZYonghu Zhang
Yonghu Zhang
WJWanshun Jiang
Wanshun Jiang
JLJin Xian Liu
Jin Xian Liu
WZWeifeng Zhu
Weifeng Zhu
In this paper we present a new ultra-wideband 20-way coaxial power combiner. In this new structure, there is a radially extended coaxial cavity and 20 coaxial coupling probes. It can not only be used as power combiner but also power divider. There are several critical parameters we'll discuss here that ultimately determine the performance of the new power combiner. The new structure can efficiently work in ultra-wideband 6GHz-18GHz range. ANSYS HFSS simulation results show that the insertion loss is less than -1dB and the return loss is below -15dB. With relatively compacted body, space is sufficiently used and manufacturing process is easy for industry production.

18 April 2026 in SSRN Electronic Journal
Verified
Preprint
Open access
PLPengbo Liu
Pengbo Liu
WZWei Feng Zhu
Wei Feng Zhu
HXHu Xu
Hu Xu
GYGuowei Yan
Guowei Yan
YCYuxuan Chen
Yuxuan Chen
YNYuning Niu
Yuning Niu
[Background]: Ionization chamber detectors are the most widely used devices in the field of nuclear radiation dose monitoring. However, since the chamber wall materials are generally neither air-equivalent nor tissue-equivalent, the detector exhibits inconsistent energy responses in gamma radiation measurements over a wide energy range, which impairs the measurement accuracy. [Purpose]: To optimize the structural design of the ionization chamber and improve the flatness of its energy response. [Methods]: A simulation model of a coaxial ionization chamber was established based on the Geant4 Monte Carlo method. The effects of filling gas composition, gas pressure, wall material, and wall thickness on the energy response to gamma rays in the energy range of 50 keV to 7 MeV were systematically investigated, and the simulation model was validated through experiments performed in standard radiation fields. [Results]: The results show that the maximum deviation between the simulation and experimental data is -5.6% @ 83 keV, indicating that the model is accurate and reliable. The gas composition only significantly affects the low-energy response: the higher the argon proportion, the more obvious the low-energy overshoot. Increasing the gas pressure improves the flatness of the low-energy region and slightly enhances the high-energy response. A low-Z chamber wall exhibits an obvious overshoot at low energies, whereas high-Z materials effectively suppress this phenomenon. Increasing the wall thickness reduces the low-energy overshoot but has a weak effect on the medium- and high-energy regions. [Conclusions]: This study clarifies the regulation laws of structural parameters on the energy response of ionization chambers, providing theoretical support for the optimal design and engineering application of wide-energy-range ionization chambers.