In this study, asphalt concrete specimens were subjected to a semicircle bending test at −10 °C to simulate the process of the development of cracks in asphalt concrete at low temperature. The acoustic emission parameters were collected during the test, the variation characteristics of acoustic emission parameters were analyzed, and the peakedness value was introduced to evaluate the damage of asphalt concrete. The dynamic evolution of fracture development was analyzed by periods with acoustic emission source location. The results indicate that the damage of asphalt mixtures shows an obvious brittle characteristic at low temperature, acoustic emission signals mainly originate from the crack damage caused by tensile stress, and the strength and number of signals can reflect the degree of crack development. Based on acoustic emission parameters and load curves, the cracking damage of asphalt concrete at low temperature in this study can be divided into three periods: a calm period, a stable development period, and a rapid fracture period. The crack point occurred and propagated upward rapidly in the rapid fracture period. During this period, acoustic emission parameters such as ringing count, acoustic emission energy, and amplitude increased suddenly; furthermore, the peakedness value reached its peak in this period and corresponded well with the low-temperature damage of asphalt concrete. Acoustic emission source location technology can track position of crack points and the propagation path of cracks, reflecting the dynamic evolution process of asphalt concrete crack damage at low temperature.
The accurate localization of an acoustic emission (AE) source is a vital aspect of AE nondestructive testing technology. A model of wave velocity attenuation caused by the extension of transmission distance is established to analyze the attenuation of AE wave velocities in concrete and thus improve the acoustic source localization accuracy from the perspective of modified velocity. In combination with the exhaustive and region localization methods, a region exhaustive localization method is established based on the modified wave velocity. The results indicate that the smaller the water–cement ratio, the larger the reference wave velocity, and the spatially dependent attenuation of wave velocity increase. Moreover, the larger the aggregate particle size, the larger the reference wave velocity, and the greater the attenuation of wave velocity with distance. For a propagation distance of 1000 mm, the AE wave velocity attenuation exceeds 50% compared with the AE velocity. The optimized localization method reduces the number of nodes calculated, thus improving the method’s accuracy when used for localization.
In this study, the semicircle three-point bending tests of ordinary asphalt concrete and basalt fiber asphalt concrete were carried out and acoustic emission parameters were collected during the test. The differences of the characteristics of acoustic emission parameters between basalt fiber asphalt concrete and ordinary asphalt concrete were analyzed, and the damage stages were divided based on the variation of acoustic emission parameters; Rise Angle and Average Frequency were introduced to study the cracking mode and crack resistance mechanism of asphalt concrete with basalt fiber. The results show that the acoustic emission parameters can well represent the toughening and crack resistance effect of basalt fiber in asphalt concrete, and the damage stages can be divided into three stages: microcrack initiation stage, fracture stage, and residual stage. The duration of the fracture stage and the load resistance time of the specimen were greatly prolonged. The proportion of shear events in the whole failure process increased greatly after the basalt fibers were added, especially in the fracture stage, which reduced the tensile failure tendency of the specimens, and thus improved the bending and tensile performance of the specimens and played a toughening and crack resistance role in the fracture stage.
Aiming for integration of a large‐scale of distributed generators (DGs) such as photovoltaic into the microgrids, the virtual synchronous generator (VSG) control concept has been developed. By this concept, DGs based on inverters can exhibit the characteristics of synchronous generators (SGs) such as the inertial, damping, and droop functions and can participate in the microgrid control and stability. Here, a detailed VSG model is presented and analysed in order to investigate that, VSGs have really the similar structure of SGs. Then, the paper studies the microgrid with both VSG and ordinary SG. Then, parallel arrangements of VSG‐VSG are set up in order to compare the dynamic behaviour of the VSG with the standard SG in an isolated microgrid. The dynamic responses are compared under equal sharing and proportional sharing of the load demand. Simulation results are presented using matlab/simulink.