In this paper, the synchronizing dynamic issue of VSC dominated power system is focused on. First, based on the discovered analogous synchronizing dynamical process of VSC (voltage source converter) and SG (synchronous generator), the dynamics of VSC's PLL (phase locked loop) is modeled in the similar form of SG's rotor motion. The influence of control interaction on PLL is modeled in the same way as that of control dynamics on rotor motion. Then the analogized SG model of PLL-based VSC is developed. Based on the proposed model, the analysis idea jointing accelerating-decelerating area method and numerical simulation is employed to study the transient synchronizing stability of single VSC infinite bus system. It is identified that the influence of ACC (alternating current control) on PLL is to accelerate PLL's equivalent motion in first swing, which aggravates the mismatch of accelerating-decelerating area and thus deteriorates the transient stability. Furtherly, the influence factors including ACC's bandwidth, PLL's bandwidth and current references on the transient stability are studied. This paper provides a useful analysis idea for transient synchronizing stability analysis of VSC with influence of control interaction considered.
21 November 2022 in IEEE Transactions on Power Systems
With large scale of wind turbines connected to high impedance AC grid, transient synchronizing stability of PLL (phase locked loop) based WTC (wind turbine converter) during LVRT (low voltage ride through) is increasing concerned. However, the existing research is usually carried out at the assumption of constant current injection. The influence of dynamic current injection adjusted by LVRT control is neglected. Yet, in high impedance AC grid, the dynamic current injection significantly affects the terminal voltage tracked by PLL. Then LVRT control has much impact on the transient synchronizing stability, which is concerned especially in this paper. First, an novel equivalent motion model is developed, in which PLL is modelled in the form of rotor motion and LVRT control adjusts its equivalent driving force similar as governor in synchronous generator. Then based on the developed model, accelerating-decelerating area method is employed to reveal the transient stability mechanism from energy's transformation and dissipation. Transient stability region method is employed to present the visualized stability region. Furtherly, the influence of K-factor, grid impedance and grid voltage sag are studied from the influence of them on accelerating-decelerating area and stability region. Finally, simulated results are presented to verify the analytical results.
21 April 2022 in IEEE Transactions on Energy Conversion
With increasing penetration of wind power, wind turbines are usually required to stay connected and provide reactive current support according to LVRT (low voltage ride through) grid code during grid faults. However, for WTC (wind turbine converter) connected to high impedance AC grid, the voltage dependent current injection required by LVRT grid code may conflict with the injection current dependent voltage response of WTC, resulting in LVRT failure. In this letter, the matching of them is studied in detail. First, the voltage dependent current injection defined by LVRT grid code and injection current dependent voltage response of WTC are developed, respectively. Then the matching of them is revealed from the source-load matching analysis of equivalent circuit. It is identified that there exists constraints on the selection of K-factor to ensure the matching during low voltage grid faults. Simulated results are also presented to verify the analysis.