Andreas Dominik

Andreas Dominik

Auto-generated profile, based on publicly available information

Andreas Dominik

THM University of Applied Sciences

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 June 2021 in npj Systems Biology and Applications
Verified
Journal Article
Open access
PDF file
CSChristopher Schölzel
Christopher Schölzel
VBValeria Blesius
Valeria Blesius
GEGernot Ernst
Gernot Ernst
ADAndreas Dominik
Andreas Dominik
Reuse of mathematical models becomes increasingly important in systems biology as research moves toward large, multi-scale models composed of heterogeneous subcomponents. Currently, many models are not easily reusable due to inflexible or confusing code, inappropriate languages, or insufficient documentation. Best practice suggestions rarely cover such low-level design aspects. This gap could be filled by software engineering, which addresses those same issues for software reuse. We show that languages can facilitate reusability by being modular, human-readable, hybrid (i.e., supporting multiple formalisms), open, declarative, and by supporting the graphical representation of models. Modelers should not only use such a language, but be aware of the features that make it desirable and know how to apply them effectively. For this reason, we compare existing suitable languages in detail and demonstrate their benefits for a modular model of the human cardiac conduction system written in Modelica.

2 June 2020 in Physiological Measurement
Verified
Journal Article
Open access
PDF file
VBValeria Blesius
Valeria Blesius
CSChristopher Schölzel
Christopher Schölzel
GEGernot Ernst
Gernot Ernst
ADAndreas Dominik
Andreas Dominik
Heart rate turbulence (HRT) is a biphasic reaction to a ventricular premature contraction (VPC) mainly mediated by the baroreflex. It can be used for risk stratification in different disease patterns. Despite existing standards there is a lot of variation in terms of measuring and calculating HRT, which complicates research and application. Objective: This systematic review outlines and evaluates the methodological spectrum of HRT research, especially filtering criteria, parameter calculation and thresholds. Approach: The analysis includes all research papers written in English that have been published before 12.10.2018, are listed on PubMed and involve calculation of HRT parameter values. Main results: HRT assessment is still being performed in various ways and important specifications of the methodology are not given in many articles. Nevertheless, some suggestions regarding HRT methodology can be made: A normalised turbulence slope should be used to uncouple the parameter from heart rate and frequency of extrasystoles. Filtering criteria as formerly reviewed in the guidelines should be met and mentioned. The minimal number of VPCSs as well as new cut-off values for different risks need to be further evaluated. Most importantly, the exact and complete methodology must be described to ensure reproducibility and comparability. Significance: Methodical variation hinders comparability of research and medical application. Our continuing questions help to further standardise the measurement and calculation of HRT and increase its value for medical risk stratification.

19 December 2024 in Interactive Journal of Medical Research
Verified
Journal Article
Open access
JLJohannes Leimhofer
Johannes Leimhofer
MPMilica Petrovic
Milica Petrovic
ADAndreas Dominik
Andreas Dominik
Dominik HeiderDominik Heider
Dominik Heider
UHUlrich Hegerl
Ulrich Hegerl
Journal of Medical Internet Research - International Scientific Journal for Medical Research, Information and Communication on the Internet #Preprint #PeerReviewMe: Warning: This is a unreviewed preprint. Readers are warned that the document has not been peer-reviewed by expert/patient reviewers or an academic editor, may contain misleading claims, and is likely to undergo changes before final publication, if accepted, or may have been rejected/withdrawn. Readers with interest and expertise are encouraged to sign up as peer-reviewer, if the paper is within an open peer-review period. Please cite this preprint only for review purposes or for grant applications and CVs (if you are the author). Background: A popular trend in depression forecasting research is the development of machine learning (ML) models trained with various types of smartphone sensor data and periodic self-ratings to derive early indications of changes in depression severity. While most works focus on model performance, there is little concern about the universal usability and reliable operation of such systems across smartphone platforms. This review serves as foundational work for the MENTINA clinical trial, which investigates smartphone-based health self-management for depression. The usability and reliability of mobile applications for depression is commonly perceived through the lens of the approaches and interventions offered rather than the reliability of the built-in mobile phone functions to support effortless and exact delivery of intended interventions. Objective: This work aimed to synthesize existing systematic reviews to identify smartphone sensor modalities used in mental health monitoring and, building on this foundation, assess the cross-platform availability of these data streams using PhoneDB to inform the design and implementation of digital depression indication systems. Methods: To identify the already used hard- and software sensors and their purposes in mental health monitoring, an umbrella review was conducted. Three electronic databases including PubMed, Web of Science Core Collection, and Scopus were searched using smartphone, sensor data, and depression keyword combination to retrieve relevant literature reviews published within the past five years (2019-2024). Once the initial search was completed, the extracted hardware sensors were checked for availability on Android and iOS smartphones by analyzing device specifications in the PhoneDB over the past ten years. Results: The extracted data streams observed across nine included studies covered sixteen hardware and three software data streams. Hardware data streams include accelerometer, barometer, battery level, Bluetooth, camera, cell, GPS, gyroscope, humidity, light, magnetometer, proximity, sound, step count, temperature, and Wi-Fi. Software data streams include app usage, call and message logs, and screen status. Hardware component availability on Android and iOS systems shows the changes in component trends from 2014 to 2024 as of September 2024 with the accelerometer, battery, camera, and GPS being consistent on Android and iOS while components such as gyroscope, step counter, and barometer were gradually increasing over the years, particularly on Android. Conclusions: Multiple data streams identified in literature reviews have shown a consistent increase in availability over time, enabling improved use of these outputs for depression forecasting and the training of machine learning models with diverse smartphone data, including sensor-derived information. For more precise and reliable data to be utilized in the mental health field, particularly in critical areas such as tracking and predicting changes in depression severity, further research is required to streamline smartphone data across varying mobile hardware and software configurations to provide reliable output for digital mental health purposes.

4 July 2017
Verified
Conference Paper
Open access
PDF file
NJNicola Justus
Nicola Justus
CSChristopher Schölzel
Christopher Schölzel
ADAndreas Dominik
Andreas Dominik
TLThomas Letschert
Thomas Letschert
The Modelica language is becoming increasingly popular among scientists and engineers as platform for modelling physical or biological systems. Although Modelica is maintained as non-proprietary language by the Modelica Association, a considerable number of commercial implementations and development environments is complemented by a surprisingly small number of open source tools. In this paper, we present the communication service Mo|E that connects any text editor as front-end with a Modelica compiler as back-end. Based on the simple HTTP communication protocol, editor plugins for a software developer's favourite text editor can be developed easily, hence turning any editor into a lightweight Modelica development tool. We also present a first implementation of a plugin for the text editor Atom that exhibits features necessary for efficient software development, such as display of compile errors, code completion, go to declaration or view of context-sensitive documentation. In addition, Modelicaspecific checking of the number of equations in a model is supported.

2 October 2020 in Frontiers in Physiology
Verified
Journal Article
Open access
PDF file
CSChristopher Schölzel
Christopher Schölzel
VBValeria Blesius
Valeria Blesius
GEGernot Ernst
Gernot Ernst
ADAndreas Dominik
Andreas Dominik
The Hodgkin-Huxley model of the squid giant axon has been used for decades as the basis of many action potential models. These models are usually communicated using just a list of equations or a circuit diagram, which makes them unnecessarily complicated both for novices and for experts. We present a modular version of the Hodgkin-Huxley model that is more understandable than the usual monolithic implementations and that can be easily reused and extended. Our model is written in Modelica using software engineering concepts, such as object orientation and inheritance. It retains the electrical analogy, but names and explains individual components in biological terms. We use cognitive load theory to measure understandability as the amount of items that have to be kept in working memory simultaneously. The model is broken down into small self-contained components in human-readable code with extensive documentation. Additionally, it features a hybrid diagram that uses biological symbols in an electrical circuit and that is directly tied to the model code. The new model design avoids many redundancies and reduces the cognitive load associated with understanding the model by a factor of 6. Extensions can be easily applied due to an unifying interface and inheritance from shared base classes. The model can be used in an educational context as a more approachable introduction to mathematical modeling in electrophysiology. Additionally the modeling approach and the base components can be used to make complex Hodgkin-Huxley-type models more understandable and reusable.

30 September 2022 in SLAS Technology
Verified
Journal Article
Open access
CDClemens Dierks
Clemens Dierks
RSRobert Söldner
Robert Söldner
KPKevin Prühl
Kevin Prühl
NWNiels Wagner
Niels Wagner
NDNoushin Delmdahl
Noushin Delmdahl
JAJonas Austerjost
Jonas Austerjost
As new technologies emerge, deep learning applications are often integral parts of new products as features and often as differentiating benefits. This is especially notable in commercial consumer products in everyday applications, such as voice assistants or streaming content recommendation systems. Due to the power and applicability of these deep learning technologies significant efforts are being directed to the development and integration of appropriate models into science and engineering applications to supplant analogue systems that may be highly prone to human error. Here we present an innovative, low-cost approach to advance sterility assessment workflows that are required and regulated within drug release/manufacturing processes. The model system leverages off-the-shelf hardware as well as deep learning models to detect and classify different microbial contaminations in test containers. The paired hardware and software tools were evaluated in experiments using common model organisms (C. sporogenes, P. aeruginosa, S. aureus). With this approach we were able to detect all three test organisms across 40 experiments, furthermore we were capable of classifying the present organisms with an average classification accuracy of over 87%.