Relationships between renal function and medical costs for deceased donor kidney transplant recipients are not fully quantified post-transplant. We describe these relationships with renal function measured by estimated glomerular filtration rate (eGFR) and graft failure. The United States Renal Data System identified adults receiving single-organ deceased donor kidneys 2012–2015. Inpatient, outpatient, other facility costs and eGFRs at discharge, 6 and 12 months were included. A time-history of costs was constructed for graft failures and monthly costs in the first year post-transplant were compared to those without failure. The cohort of 24,021 deceased donor recipients had a 2.4% graft failure rate in the first year. Total medical costs exhibit strong trends with eGFR. Recipients with 6-month eGFRs of 30–59 ml/min/1.73m2 have total costs 48% lower than those <30 ml/min/1.73m2. For recipients with graft failure monthly costs begin to rise 3–4 months prior to failure, with incremental costs of over $38,000 during the month of failure. Mean annual total incremental costs of graft failure are over $150,000. Total costs post-transplant are strongly correlated with eGFR. Graft failure in the first year is an expensive, months-long process. Further reductions in early graft failures could yield significant human and economic benefits.
In population-oriented ergonomics product design and musculoskeletal kinetics analysis, digital spine models of different shape, pose and material property are in great demand. The purpose of this study was to construct a parameterized finite element spine model with adjustable spine shape and material property. We used statistical shape model approach to learn inter-subject shape distribution from 65 CT images of training subjects. Second order polynomial regression was used to model the age-dependent changes in vertebral material property derived from spatially aligned CT images. Finally, a parametric spine generator was developed to create finite element instances of different shapes and material properties. For quantitative analysis, the generalization ability to emulate spine shapes of different people was evaluated by fitting into 17 test CT images. The median fitting accuracy was 0.8 for Dice coefficient and 0.43 mm for average surface distance. The age-dependent bone density regression curve was also proved to well agree with large population statistics data. Finite element simulation was performed to compare how shape parameters influenced the biomechanics distribution of spine. The proposed parametric finite element whole spine model will assist the design process of new devices and biomechanical simulation towards a wide range of population.
INPLASY202320117 Aspirin Versus Low-Molecular-Weight Heparin for Venous Thromboembolism Prophylaxis in Patients after Postoperative Joint Surgery: A Meta-Analysis Keywords: Aspirin; Low-Molecular-W…
High-speed railways often run over underground metro stations. Dynamic load induced by high-speed train can influence the internal force of underground structure and hence can pose danger to the underground structure. Hence, it is necessary to estimate the safety of underground structure due to high-speed train load. In this paper, the effects of dynamic load induced by high-speed train on metro station are investigated by carrying out three-dimensional numerical analysis. Guinan high-speed railway, which is designed to run over Jinqiao metro station in Nanning, Guangxi province of China are adopted as the background of this case study. The hardening soil model with small-strain stiffness was adopted to model the behaviour of soil. Two typical speed of railway train (i.e., 160 km/h and 350 km/h) are considered in this study. Based on the numerical analysis, vertical vibration acceleration and bending moment of the structure of the metro station are presented and analysed.