Sang Yul Yang

Sang Yul Yang

Auto-generated profile, based on publicly available information

Sang Yul Yang

School of Mechanical Engineering, Sungkyunkwan University, Suwon, South Korea

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 September 2017 in Smart Materials and Structures
Verified
Journal Article
Closed access
PDF file
SYSang Yul Yang
Sang Yul Yang
KCKyeong Ho Cho
Kyeong Ho Cho
YKYoungeun Kim
Youngeun Kim
MSMin-Geun Song
Min-Geun Song
HJHo Sang Jung
Ho Sang Jung
HCHyouk Ryeol Choi
Hyouk Ryeol Choi
This paper reports the twisted and coiled soft actuator (abbreviated with STCA) with spandex fiber. The STCA exhibits higher actuation strain at lower temperature than the previous nylon twisted and coiled soft actuators (abbreviated with NTCAs). While NTCAs are fabricated using a twist-insertion process until coils are formed, a new method is developed to fabricate the STCA using the ultra-stretch of spandex, whereby the STCA is twisted again after the coil has been formed. A 6-gear-twist-insertion device that increases the stability and the fabrication speed is developed to fabricate the STCA. The superior performance exhibited by the STCA is due to the 14% contraction strain of the bare spandex (bare nylon: 4%) and the low spring constant of 0.0115 N mm −1 . The maximum tensile actuation strain of STCA was 45% at 130 °C, and the maximum specific work was 1.523 kJ kg −1 at 130 °C. STCA could repeatedly actuate 100 times with a strain change of less than 0.4%.

21 April 2021 in Cyborg and Bionic Systems
Verified
Journal Article
Open access
PDF file
JSJinho So
Jinho So
UKUikyum Kim
Uikyum Kim
YKYong Bum Kim
Yong Bum Kim
DSDong-Yeop SEOK
Dong-Yeop SEOK
SYSang Yul Yang
Sang Yul Yang
HCHyouk Ryeol Choi
Hyouk Ryeol Choi
The soft robot manipulator is attracting attention in the surgical fields with its intrinsic softness, lightness in its weight, and safety toward the human organ. However, it cannot be used widely because of its difficulty of control. To control a soft robot manipulator accurately, shape sensing is essential. This paper presents a method of estimating the shape of a soft robot manipulator by using a skin-type stretchable sensor composed of a multiwalled carbon nanotube (MWCNT) and silicone (p7670). The sensor can be easily fabricated and applied by simply attaching it to the surface of the soft manipulator. In its fabrication, MWCNT is sprayed on a teflon sheet, and liquid-state silicone is poured on it. After curing, we turn it over and cover it with another silicone layer. The sensor is fabricated with a sandwich structure to decrease the hysteresis of the sensor. After calibration and determining the relationship between the resistance of the sensor and the strain, three sensors are attached at 120° intervals. Using the obtained data, the curvature of the manipulator is calculated, and the entire shape is reconstructed. To validate its accuracy, the estimated shape is compared with the camera data. We experiment with three, six, and nine sensors attached, and the result of the error of shape estimation is compared. As a result, the minimum tip position error is approximately 8.9 mm, which corresponded to 4.45% of the total length of the manipulator when using nine sensors.

19 January 2017 in International Journal of Control, Automation, and Systems
Verified
Journal Article
Closed access
PDF file
HJHo Sang Jung
Ho Sang Jung
SYSang Yul Yang
Sang Yul Yang
KCKyeong Ho Cho
Kyeong Ho Cho
MSMin Geun Song
Min Geun Song
CNCanh Toan Nguyen
Canh Toan Nguyen
HCHyouk Ryeol Choi
Hyouk Ryeol Choi

31 January 2022 in Composites Science and Technology
Verified
Journal Article
Closed access
YKYongjun Kim
Yongjun Kim
KFK.P. Faseela
K.P. Faseela
SYSang Yul Yang
Sang Yul Yang
KKKihyeon Kim
Kihyeon Kim
HYHee Ju Yu
Hee Ju Yu
SBSeunghyun Baik
Seunghyun Baik

31 May 2018 in Smart Materials and Structures
Verified
Journal Article
Closed access
PDF file
HJHo Sang Jung
Ho Sang Jung
KCKyeong Ho Cho
Kyeong Ho Cho
JPJae Hyeong Park
Jae Hyeong Park
SYSang Yul Yang
Sang Yul Yang
YKYoungeun Kim
Youngeun Kim
HCHyouk Ryeol Choi
Hyouk Ryeol Choi
The purpose of this study is to develop an artificial muscle actuator suitable for robotic applications, and to demonstrate the feasibility of applying this actuator to an arm mechanism, and controlling it delicately and smoothly like a human being. To accomplish this, we perform the procedures that integrate the soft actuator, called the single body dielectric elastomer actuator, which is very flexible and capable of high speed operation, and the displacement amplification mechanism called the sliding filament joint mechanism, which mimics the sliding filament model of human muscles. In this paper, we describe the characteristics and control method of the actuation system that consists of actuator, mechanism, and embedded controller, and show the experimental results of the closed-loop position and static stiffness control of the robotic arm application. Finally, based on the results, we evaluate the performance of this application.

1 February 2023 in Soft Robotics
Verified
Journal Article
Closed access
SYSang Yul Yang
Sang Yul Yang
KKKihyeon Kim
Kihyeon Kim
JKJeong U. Ko
Jeong U. Ko
SSSungwon Seo
Sungwon Seo
SHSeong Taek Hwang
Seong Taek Hwang
HCHyouk Ryeol Choi
Hyouk Ryeol Choi
Twisted and coiled actuators (TCAs), which are light but capable of producing significant power, were developed in recent times. After their introduction, there have been numerous improvements in performance, including development of techniques such as actuation strain and heating methods. However, the development of robots using TCA is still in its early stages. In this study, a bionic arm driven by TCAs was developed for light and flexible operation. The aim of this study was to gain a foothold in the future of robot development using TCA, which is considered as the appropriate artificial muscle. The main developments were with regard to the design (from actuator design to system design), system configuration for control, and control method. First, a process technology for repeatedly manufacturing TCA, which can be used practically and delivers sufficient performance, was developed. Based on the developed actuator, a joint was designed to move the elbow and hand. The final bionic arm was developed by integrating the TCA, pulley joint, and control system. It moved the elbow up to 100° and allowed the hand to move in three degrees of freedom. Using the control method for each joint, we were able to show the movement by using the hand and elbow.