1 March 2019 in Annals of Saudi Medicine
The number of cochlear implant (CI) recipients is increasing so there needs to be greater awareness of possible CI complications. Describe complications of CI. Retrospective, descriptional. Tertiary health care center. Data was collected by retrospective chart review on complications for recipients implanted for the period from January 2006 to June 2017. Major and minor post cochlear implantation complications. 1027 cochlear implant recipients. Post-operative complications were reported in 105 patients (10.2%). Minor complications were most often encountered (9.5%). Swelling (wound seroma or hematoma) was the most common complication. The major complication rate was only 7/105, 0.7%. Meningitis did not occur and cholesteatoma occurred in only one patient. CI is a safe surgical procedure at our center. We believe that this is probably due to the preoperative protocol, the surgical technique used, and the postoperative care conducted for all our patients. Despite this, it is important that both physicians and patients have knowledge of the possible consequences and risks posed by CI, especially in view of the fact that these patients require lifetime follow-up. Further studies are needed, and should include more ENT centers across all regions of Saudi Arabia. None.
28 March 2020 in The Laryngoscope
17 August 2020 in Otology & Neurotology
Objectives: Different options are available for hearing restoration in patients with aural atresia. Middle ear implantation with the Vibrant Soundbridge (VSB) has been used successfully in many patients with aural atresia with conductive or mixed hearing loss. The aim of the current study was to assess the safety and the efficiency of VSBs coupled to the short process of the incus in patients with aural atresia with conductive or mixed hearing loss. Methods: The study was a retrospective chart review conducted at a tertiary university hospital. Audiological and surgical data from six ears with aural atresia implanted with VSBs coupled to the short process of the incus were analyzed. The audiological results were compared with previously reported results obtained after the utilization of different coupling techniques. Results: All six atretic ears were successfully implanted using the short process coupler, and there were no major complications. Postoperative bone conduction thresholds did not differ substantially from preoperative thresholds. The respective mean preoperative pure-tone average 4, speech reception threshold, and word recognition score values were 56.7 dB, 61.7 dB, and 44%. Postoperative pure-tone average 4 thresholds (25 ± 3.5 dB) and speech reception thresholds (20.8 ± 8 dB) were significantly improved. The maximum postoperative word recognition score achieved was 100%. The audiological outcomes obtained were similar to previously reported outcomes after classic stapes placement. Conclusion: Coupling of the floating mass transducer to the short process of the incus in patients with aural atresia resulted in significant audiological improvements that were comparable to previously reported improvements after placement via other methods.
1 May 2020 in Saudi Medical Journal
AAAbdulrahman A. Alsanosi
To determine whether family environment and demographic factors such as family income and education produce any significant difference in postoperative performance of cochlear implant (CI) patients. In this study, 49 participants who received cochlear implant devices at King Abdullah Ear Specialist Center, Riyadh, Saudi Arabia before the age 5 years were included. Data were collected between July 2019 and August 2019. Postoperative performance was assessed by speech intelligibility rating (SIR) and categories of auditory performance (CAP) scales. Family environment was assessed with family environment scale (FES) survey. Data of demography, average income, and maternal and paternal education were obtained through review of patient's medical files. The data obtained were analyzed using Statistical Package for Social Sciences for Mac, version 23 (IBM Corp, Armonk, NY, USA). A significant difference between the organization categories of FES (p less than 0.05) was observed in terms of postoperative CAP scores, while a significant effect of the expressiveness category on both postoperative CAP and SIR scores (p less than 0.05) was observed. The scores on both CAP and SIR scales were significantly affected by maternal education, and the scores on SIR scale were positively correlated with paternal education. This study suggests that post-procedural performance of auditory perception and speech intelligibility in CI patients is significantly related to the family environment as well as the education levels of the parents.
28 July 2020 in The Journal of International Advanced Otology
OBJECTIVES: This paper attempts to create a new classification type of cochlear hypoplasia (CH)-type malformation taking into consideration of vestibular section and internal auditory canal (IAC). MATERIALS and METHODS: Preoperative computed-tomography (CT) scans of cochlear implant (CI) candidates (N=31) from various clinics across the world with CH type malformation were taken for analysis. CT dataset were loaded into 3D-slicer freeware for three-dimensional (3D) segmentation of the inner-ear by capturing complete inner-ear structures from the entire dataset. Cochlear size in terms of diameter of available cochlear basal turn and length of cochlear lumen was measured from the dataset. In addition, structural connection between IAC and cochlear portions was scrutinized, which is highly relevant to the proposed CH classification in this study. RESULTS: CH group-I has the normal presence of IAC leading to cochlear and vestibular portions, whereas CH group-II is like CH group-I but with some degree of disruption in vestibular portion. In CH group-III, a disconnection between IAC and the cochlear portion irrespective of other features. Within all these three CH groups, the basal turn diameter varied between 3.1 mm and 9.6 mm, and the corresponding cochlear lumen length varied between 3 mm and 21 mm for the CI electrode array placement. CONCLUSION: A new classification of CH mainly based on the IAC connecting the cochlear and vestibular portions is presented in this study. CI electrode array length could be selected based on the length of the cochlear lumen, which can be observed from the 3D image. Cite this article as: Halawani RT, Dhanasingh A. New Classification of Cochlear Hypoplasia Type Malformation: Relevance in Cochlear Implantation. J Int Adv Otol 2020; 16(2): 153-7.
31 March 2022 in Ear, Nose & Throat Journal
Although hemangiomas are common in the head and neck area, they are uncommon in the temporal bone. External auditory canal (EAC) hemangiomas are a relatively uncommon otologic condition. In the English literature, only 29 cases of temporal bone hemangioma have been reported. We also present the case of a 32-year-old male patient who presented with an 8-month history of decreased hearing, tinnitus, and aural fullness on the right side. Otoscopic examination of the right ear revealed a smooth, oval, well-circumscribed, reddish, pulsatile, nontender mass, which was about 1 cm in diameter and occupied two-thirds of the EAC. It was soft in consistency, compressible, and appeared to be arising from the right posterior-superior portion of the bony canal wall; the tympanic membrane seemed to be uninvolved. The patient had mild conductive hearing loss of the right ear with an average air-bone gap of 20 dB; the left side was normal. High-resolution contrast-enhanced computed tomographic scanning of the temporal bone showed well-defined, rounded, homogenously enhancing lesions at the posterior-superior aspect of right EAC measuring 0.7 × 0.8 cm. Angiography was performed and there was evidence of vascular blush in the region of the right EAC. Three blood vessels were identified and embolized. The mass was completely removed by the endaural approach, and a retroauricular skin graft to restore cutaneous integrity was not required. Histopathology indicated a capillary hemangioma without cytological atypia or mitotic activity. There was no recurrence 1 year after the surgery.