6 November 2020 in IEEE Access
In inductive power transfer (IPT) system, the magnetic coupling has significant effects on power and system efficiency. The voltage and current on the secondary side are coupling dependent. Load measurements are not possible through sensors on the primary side. This paper proposes the secondary-side voltage controller based on the primary-side control by means of bifurcation approach. The main advantage of operation under bifurcation is that the coupling and load on the secondary have no effect on the voltage gain. This enables the secondary voltage control through the primary voltage. With the proposed sensing coil on the primary side, the bifurcation detection is possible. The proposed control can utilize the frequency split phenomenon and track the bifurcation frequency to ensure maximum efficiency in various coupling conditions. In addition, the design guidelines of the parallel-parallel compensation configuration are introduced for a desired load profile and transfer distance. The constant voltage gain with respect to conditions of magnetic coupling variation is verified by using finite element analysis and experimental study. A 1-kW IPT prototype is constructed to validate the proposed bifurcation detection and voltage control. Experimental results show that the proposed IPT can achieve up to 90% of maximum efficiency while maintaining constant secondary voltage.
21 August 2025 in IEEE Access
Despite the increasing popularity, unmanned aerial vehicles (UAVs) are often hindered by limited battery endurance and complexities of in-flight recharging. This paper presents an extended-range wireless power transfer (WPT) system designed for simultaneous in-flight charging of dual drones. By employing a bifurcation approach, the system uses bifurcation-induced zero-phase angle (ZPA) frequencies to achieve coupling-independent current gain. This allows the system to maintain a constant battery charging current across dynamically varying coupling conditions, without the need for sensors or communication modules on the receiver drones. Finite element simulation study confirms the magnetic flux density characteristics, desired for practical operation constraints. An experimental study on a 500 W prototype demonstrates the proposed system’s effectiveness. The dual-receiver configuration successfully maintains a constant 5 A charging current of each drone while extending the operational air gap range by 16.7% (from 150 mm to 175 mm) compared to single-receiver scenarios. This work presents a practical solution that mitigates misalignment and air gap variation issues to enhance UAV flight endurance, an important step for drone operations during prolonged missions.
21 May 2024 in IEEE Access
In a dynamic inductive power transfer (D-IPT) system, significant variations in magnetic coupling occur as the secondary coil moves along the roadway above the primary coils. These variations significantly impact the output power pulsation and result in low power efficiency. This article introduces the concept of a D-IPT system operating under the bifurcation phenomenon that achieves coupling-independent and load-independent output characteristics by tracking the new zero phase angle (ZPA) frequency. The series-series (SS) topology was chosen as the IPT system can control the secondary current via the input current under the bifurcation phenomenon. Furthermore, the proposed circuit configuration on the primary side eliminates the high-power loss associated with SS topology within non-coupling primary coils—the primary coils are not synchronized with the vehicle—at the new ZPA frequency under the bifurcation phenomenon. The experimental results from the hardware prototype illustrated that the output power at the secondary side remained relatively constant, around 200 W. This was achieved by regulating the secondary current via the input current throughout the experimental distance.
29 December 2023 in IEEE Access
A conventional coil configuration of electromagnetic levitation melting (ELM) systems consists of a main coil connected with an anti-loop coil to provide the stability of the levitating workpiece. The reversed current in the anti-loop coil produces a reversed magnetic field that depreciates the total magnetic flux at the workpiece. In many cases, a smaller reversed current is sufficient to provide stabilization for a levitating workpiece. This paper proposes a mutually coupled stabilization coil in place of the anti-loop coil to improve the performance of ELM systems. The proposed stabilization coil system consists of two coils, an isolated upper coil, and a main levitation coil. The two coils are galvanically isolated while magnetically linked. The upper coil current is adjustable through the distance between the coils. This allows the upper coil to operate at a lower current than the main coil current but sufficient for the workpiece stabilization. Simulation results have confirmed that the magnetic flux density at the workpiece is higher in the isolation configuration than in the conventional anti-loop configuration. Experimental results have shown that the proposed system can improve the ELM system performance by reducing the heating time and power consumption of the melting process.
28 March 2024 in IEEE Access
Wireless power transfer (WPT) system consists of at least two weakly mutual coupled resonant circuits which are tuned to be operated at the same resonant frequency. Since the parameters (i.e. coupling coefficient, load resistance, etc.) could be varied, the multiple zero-phase angle (ZPA) frequencies would be occurred. This phenomenon is known as bifurcation. Some literatures avoid the bifurcation due to its instability issues. Additionally, the bifurcation cannot be easily handled by using the simple variable frequency controller. However, it offers main advantage of coupling-independent operation, allowing the constant voltage or current control regardless of variations in coupling coefficients. Typically, the critical coupling coefficient ( kcri ) is primarily employed for bifurcation criterion during operation. Unfortunately, the exact value of kcri is rather difficult to be obtained in the real system. In this paper, the bifurcation identification from magnetic flux distribution is therefore proposed. Thanks to the unique patterns of magnetic flux distribution at the resonant and bifurcation frequencies, the TMR sensors array can be properly installed to detect the bifurcation through the measured magnetic flux density. The simulated studies and results of finite element method (FEM), using COMSOL Multiphysics, are included for verifications. In addition, the proposed method is implemented and validated basing on the 400W Series-Series WPT hardware prototype. The experimental results show that the sensing voltages from TMR sensors can be effectively used for the detection of bifurcation and lateral misalignment position.