Caroline Oliveira Ribeiro

Caroline Oliveira Ribeiro

Auto-generated profile, based on publicly available information

Caroline Oliveira Ribeiro

Biomedical Instrumentation Laboratory, Institute of Biology and Faculty of Engineering, State University of Rio de Janeiro, Rio de Janeiro, Brazil

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2018 in International Journal of Chronic Obstructive Pulmonary Disease
Verified
Journal Article
Open access
PDF file
CRCaroline O Ribeiro
Caroline O Ribeiro
AFAlvaro Camilo Dias Faria
Alvaro Camilo Dias Faria
Agnaldo José LopesAgnaldo José Lopes
Agnaldo José Lopes
PMPedro Melo
Pedro Melo
Purpose: The aim of the present study was to evaluate the performance of the forced oscillation technique (FOT) for the early diagnosis of the effects of smoking and COPD. The contributions of the integer-order (InOr) and fractional-order (FrOr) models were also evaluated. Patients and methods: In total, 120 subjects were analyzed: 40 controls, 40 smokers (20.3±9.3 pack-years) and 40 patients with mild COPD. Results: Initially, it was observed that traditional FOT parameters and the InOr and FrOr models provided a consistent description of the COPD pathophysiology. Mild COPD introduced significant increases in the FrOr inertance, damping factor and hysteresivity (P<0.0001). These parameters were significantly correlated with the spirometric parameters of central and small airway obstruction (P0.8). The use of FrOr modeling significantly improved this process (P0.9). Conclusion: FrOr modeling improves our knowledge of modifications that occur in the early stages of COPD. Additionally, the findings of the present study provide evidence that these models may play an important role in the early diagnosis of COPD, which is crucial for improving the clinical management of the disease.

1 December 2020 in International Journal of Chronic Obstructive Pulmonary Disease
Verified
Journal Article
Open access
PDF file
CRCaroline Oliveira Ribeiro
Caroline Oliveira Ribeiro
Agnaldo José LopesAgnaldo José Lopes
Agnaldo José Lopes
PMPedro Melo
Pedro Melo
Purpose: This research examines the emerging role of respiratory oscillometry associated with integer (InOr) and fractional order (FrOr) respiratory models in the context of groups of patients with increasing severity. The contributions to our understanding of the respiratory abnormalities along the course of increasing COPD severity and the diagnostic use of this method were also evaluated. Patients and Methods: Forty-five individuals with no history of smoking or pulmonary diseases (control group) and 141 individuals with diagnoses of COPD were studied, being classified into 45 mild, 42 moderate, 36 severe and 18 very severe cases. Results: This study has shown initially that the course of increasing COPD severity was adequately described by the model parameters. This resulted in significant and consistent correlations among these parameters and spirometric indexes. Additionally, this evaluation enhanced our understanding of the respiratory abnormalities in different COPD stages. The diagnostic accuracy analyses provided evidence that hysteresivity, obtained from FrOr modeling, allowed a highly accurate identification in patients with mild changes [area under the receiver operator characteristic curve (AUC)= 0.902]. Similar analyses in groups of moderate and severe patients showed that peripheral resistance, derived from InOr modeling, provided the most accurate parameter (AUC=0.898 and 0.998, respectively), while in very severe patients, traditional, InOr and FrOr parameters were able to reach high diagnostic accuracy (AUC> 0.9). Conclusion: InOr and FrOr modeling improved our knowledge of the respiratory abnormalities along the course of increasing COPD severity. In addition, the present study provides evidence that these models may contribute in the diagnosis of COPD. Respiratory oscillometry exams require only tidal breathing and are easy to perform. Taken together, these practical considerations and the results of the present study suggest that respiratory oscillometry associated with InOr and FrOr models may help to improve lung function tests in COPD.

1 March 2024 in International Journal of Chronic Obstructive Pulmonary Disease
Verified
Journal Article
Open access
PDF file
ETElayne Moura Teixeira
Elayne Moura Teixeira
CRCaroline Oliveira Ribeiro
Caroline Oliveira Ribeiro
Agnaldo José LopesAgnaldo José Lopes
Agnaldo José Lopes
PMPedro Melo
Pedro Melo
Purpose: Chronic obstructive pulmonary disease (COPD) phenotypes may introduce different characteristics that need to be known to improve treatment. Respiratory oscillometry provides a detailed analysis and may offer insight into the pathophysiology of COPD. In this paper, we used this method to evaluate the differences in respiratory mechanics of COPD phenotypes. Patients and Methods: This study investigated a sample of 83 volunteers, being divided into control group (CG = 20), emphysema (n = 23), CB (n = 20) and asthma-COPD overlap syndrome (ACOS, n = 20). These analyses were performed before and after bronchodilator (BD) use. Functional capacity was evaluated using the Glittre‑ADL test, handgrip strength and respiratory pressures. Results: Initially it was observed that oscillometry provided a detailed description of the COPD phenotypes, which was consistent with the involved pathophysiology. A correlation between oscillometry and functional capacity was observed (r=− 0.541; p = 0.0001), particularly in the emphysema phenotype (r = − 0.496, p = 0.031). BD response was different among the studied phenotypes. This resulted in an accurate discrimination of ACOS from CB [area under the receiver operating curve (AUC) = 0.84] and emphysema (AUC = 0.82). Conclusion: These results offer evidence that oscillatory indices may enhance the comprehension and identification of COPD phenotypes, thereby potentially improving the support provided to these patients.

1 May 2022 in International Journal of Chronic Obstructive Pulmonary Disease
Verified
Journal Article
Open access
PDF file
CRCaroline Oliveira Ribeiro
Caroline Oliveira Ribeiro
Agnaldo José LopesAgnaldo José Lopes
Agnaldo José Lopes
PMPedro Melo
Pedro Melo
Purpose: Respiratory oscillometry has emerged as a powerful method for detecting respiratory abnormalities in COPD. However, this method has not been widely introduced into clinical practice. This limitation arises, at least in part, because the clinical meaning of the oscillometric parameters is not clear. In this paper, we evaluated the association of oscillometry with functional capacity and its ability to predict abnormal functional capacity in COPD. Patients and Methods: This cross-sectional study investigated a control group formed by 30 healthy subjects and 30 outpatients with COPD. The subjects were classified by the Glittre‑ADL test and handgrip strength according to the functional capacity. Results: This study has shown initially that subjects with abnormal functional capacity had a higher value for resistance (p < 0.05), reactance area (Ax, p < 0.01), impedance modulus (Z4, p < 0.05), and reduced dynamic compliance (Cdyn, p < 0.05) when compared with subjects with normal functional capacity. This resulted in significant and consistent correlations among resistive oscillometric parameters (R=− 0.43), Cdyn (R=− 0.40), Ax (R = 0.42), and Z4 (R = 0.41) with exercise performance. Additionally, the effects of exercise limitation in COPD were adequately predicted, as evaluated by the area under the curve (AUC) obtained by receiver operating characteristic analysis. The best parameters for this task were R4-R20 (AUC = 0.779) and Ax (AUC = 0.752). Conclusion: Respiratory oscillometry provides information related to functional capacity in COPD. This method is also able to predict low exercise tolerance in these patients. These findings elucidate the physiological and clinical meaning of the oscillometric parameters, improving the interpretation of these parameters in COPD patients.

1 October 2024 in Journal of Asthma and Allergy
Verified
Journal Article
Open access
PDF file
MPMonique da Silva Pinto
Monique da Silva Pinto
CRCaroline de Oliveira Ribeiro
Caroline de Oliveira Ribeiro
PSPaula Morisco de Sá
Paula Morisco de Sá
HCHermano Albuquerque Castro
Hermano Albuquerque Castro
TBThiago Bártholo
Thiago Bártholo
PMPedro Melo
Pedro Melo
Background: Asthma onset or worsening of the disease in adulthood may be associated with occupational asthma (OA) or work-exacerbated asthma (WEA). Oscillometry and respiratory modeling offer insight into the pathophysiology and contribute to the early diagnosis of respiratory abnormalities. Purpose: This study aims to compare the changes due to OA and WEA and evaluate the diagnostic accuracy of this method. Patients and Methods: Ninety-nine volunteers were evaluated: 33 in the control group, 33 in the OA group, and 33 in the WEA group. The area under the receiver operator characteristic curve (AUC) was used to describe diagnostic accuracy. Results: Oscillometric analysis showed increased resistance at 4 hz (R4, p< 0.001), 20 hz (R20, p< 0.05), R4-R20 (p< 0.0001), and respiratory work (p< 0.001). Similar analysis showed reductions in dynamic compliance (p< 0.001) and ventilation homogeneity, as evaluated by resonance frequency (Fr, p< 0.0001) and reactance area (p< 0.0001). Respiratory modeling showed increased peripheral resistance (p< 0.0001), hysteresivity (p< 0.0001), and damping (p< 0.0001). No significant changes were observed comparing OA with WEA in any parameter. For OA, the diagnostic accuracy analyses showed Fr as the most accurate among oscillometric parameters (AUC=0.938), while the most accurate from respiratory modeling was hysteresivity (AUC=0.991). A similar analysis for WEA also showed that Fr was the most accurate among traditional parameters (AUC=0.972), and hysteresivity was the most accurate from modeling (AUC=0.987). The evaluation of differential diagnosis showed low accuracy. Conclusion: Oscillometry and modeling have advanced our understanding of respiratory abnormalities in OA and WEA. Furthermore, our study presents evidence suggesting that these models could aid in the early diagnosis of these diseases. Respiratory oscillometry examinations necessitate only tidal breathing and are straightforward to conduct. Collectively, these practical considerations, coupled with the findings of our study, indicate that respiratory oscillometry in conjunction with respiratory modeling, may enhance lung function assessments in OA and WEA.

1 January 2023 in Brazilian Journal of Medical and Biological Research
Verified
Journal Article
Open access
PDF file
CSC.M.S. Sousa
C.M.S. Sousa
APA.L.C. Pessoa
A.L.C. Pessoa
LCL.E. Carelli
L.E. Carelli
CRC.O. Ribeiro
C.O. Ribeiro
Agnaldo José LopesAgnaldo José Lopes
Agnaldo José Lopes
PMPedro Melo
Pedro Melo
Scoliosis is a condition that affects the spine and causes chest rotation and trunk distortion. Individuals with severe deformities may experience dyspnea on exertion and develop respiratory failure. Respiratory oscillometry is a simple and non-invasive method that provides detailed information on lung mechanics. This work aims to investigate the potential of oscillometry in the evaluation of respiratory mechanics in patients with scoliosis and its association with physical performance. We analyzed 32 volunteers in the control group and 32 in the scoliosis group. The volunteers underwent traditional pulmonary function tests, oscillometry, and the 6-minute walk test (6MWT). Oscillometric analysis showed increased values of resistance at 4 Hz (R4, P<0.01), 12 Hz (R12, P<0.0001), and 20 Hz (R20, P<0.01). Similar analysis showed reductions in dynamic compliance (Cdyn, P<0.001) and ventilation homogeneity, as evaluated by resonance frequency (fr, P<0.001) and reactance area (Ax, P<0.001). Respiratory work, described by the impedance modulus, also showed increased values (Z4, P<0.01). Functional capacity was reduced in the group with scoliosis (P<0.001). A significant direct correlation was found between Cobb angle and R12, AX, and Z4 (P=0.0237, P=0.0338, and P=0.0147, respectively), and an inverse correlation was found between Cdyn and Cobb angle (P=0.0190). These results provided new information on respiratory mechanics in scoliosis and are consistent with the involved pathophysiology, suggesting that oscillometry may improve lung function tests for patients with scoliosis.