Mosaic crystals, with their high integrated reflectivities, are widely employed in spectrometers used to diagnose high energy density systems. X-ray Thomson scattering (XRTS) has emerged as a powerful diagnostic tool of these systems, providing in principle direct access to important properties such as the temperature via detailed balance. However, the measured XRTS spectrum is broadened by the spectrometer instrument function (IF), and without careful consideration of the IF one risks misdiagnosing system conditions. Here, we consider in detail the IF of 40 and 100 μm mosaic Highly Annealed Pyrolytic Graphite crystals, and how the broadening varies across the spectrometer in an energy range of 6.7–8.6 keV. Notably, we find a strong asymmetry in the shape of the IF toward higher energies. As an example, we consider the effect of the asymmetry in the IF on the temperature inferred via XRTS for simulated 80 eV CH plasmas and find that the temperature can be overestimated if an approximate symmetric IF is used. We, therefore, expect a detailed consideration of the full IF will have an important impact on system properties inferred via XRTS in both forward modeling and model-free approaches.
Achieving practical inertial fusion energy (IFE) requires the development of target designs with well-characterized microstructure and compression response. We measured shock dynamics in low-density (17.5–500 mg/cm3) aerogel and two-photon polymerization (TPP) foams using x-ray phase contrast imaging (XPCI) methods and the Velocity Interferometer System for Any Reflector. By analyzing shock front evolution, we examined how target type and density influence shock propagation and energy dissipation. Talbot-XPCI shows that aerogels support a smooth, bowed shock front due to their homogeneous nanometer-scale pore network. In contrast, TPP foams exhibit irregular, stepwise propagation driven by interactions with their periodic micrometer-scale lattice. Shock velocity follows a power-law relation: aerogels deviate from classical ρ−1/2 scaling due to pore-collapse dissipation, while TPP foams follow the trend with larger uncertainties from density variations. Comparisons with xRAGE simulations reveal systematic underestimation of shock speeds. These results provide the first experimental constraints on shock propagation in TPP foams over a wide density range and highlight the influence of internal structure on anisotropic shock behavior. Our findings support improved benchmarking of EOS and hydrodynamic models and inform the design of foam architectures that promote implosion symmetry in IFE capsules.
Understanding the behavior of polymer foams at high energy density conditions is crucial to advance inertial fusion energy research. Here, we present a new experimental platform designed to measure the thermodynamic state of these materials at megabar pressures. At the Matter in Extreme Conditions Endstation of the Linac Coherent Light Source, we heat samples using an optical, high-intensity, femtosecond laser and dynamically probe them with ultra-short, coherent x-ray pulses of high peak brightness. We perform x-ray Thomson scattering measurements in forward and backward scattering geometries to capture both collective and non-collective electron behavior in the sample. Simultaneously, x-ray fluorescence spectroscopy is used to measure the emission from a mid-Z dopant, providing complementary information on the plasma conditions. By combining these techniques, we obtain temporally resolved temperature measurements of the transient warm dense matter states. Our initial experiments designed to benchmark the platform with carbon samples yielded data resolving the ultrafast response to laser heating with sub-picosecond resolution, measuring plasma temperatures exceeding 50 eV. These findings lay the foundation for precision studies of the dynamic evolution of laser-heated polymer foams.
X-ray Thomson scattering (XRTS) has emerged as a valuable diagnostic for matter under extreme conditions, as it captures the intricate many-body physics of the probed sample. Recent advances, such as the model-free temperature diagnostic of Dornheim et al. [Nat. Commun. 13, 7911 (2022)], have demonstrated how much information can be extracted directly within the imaginary-time formalism. However, since the imaginary-time formalism is a concept often difficult to grasp, we provide here a systematic overview of its theoretical foundations and explicitly demonstrate its practical applications to temperature inference, including relevant subtleties. Furthermore, we present recent developments that enable the determination of the absolute normalization, Rayleigh weight, and density from XRTS measurements without reliance on uncontrolled model assumptions. Finally, we outline a unified workflow that guides the extraction of these key observables, offering a practical framework for applying the method to interpret experimental measurements.
X-ray Thomson scattering (XRTS) is a common diagnostic used in the warm dense matter (WDM) regime to estimate plasma parameters like density, temperature, and charge state. Experimental analysis typically relies on a forward model to obtain estimates for these parameters, as the measured spectrum is a convolution of the dynamic structure factor (DSF) and the source-instrument function. The Chihara decomposition, where the spectrum is separated into contributions from bound and free electrons, is commonly used to estimate DSFs in the WDM regime, as it allows for the fast calculation of DSFs and therefore can easily be applied in a large-scale parameter optimization. Due to the limited availability of XRTS codes, we present “x-ray diagnostics, analysis, verification, and exploration”, a code designed to quickly estimate DSFs using the Chihara decomposition and analyze experimental spectra. The code is validated by re-analyzing an experiment with isochorically heated beryllium at the OMEGA Laser Facility. In addition, we demonstrate the applicability of the code to plan experiments and predict scattering spectra through the coupling to a ray-tracing code. Finally, the importance of accounting for the energy-dependence of spectrometer instrument functions is demonstrated by comparing ray-tracing simulations to the standard convolution for strongly compressed beryllium experiments at the National Ignition Facility, similar to previously published results.
1 October 2026 in Review of Scientific Instruments
We present the design, magnetic field characterization, simulated response, and first experimental deployment of the Adaptable Magnetic Particle Spectrometer (AMPS) for broadband hot-electron diagnostics in laser–plasma experiments. AMPS uses a modular permanent-magnet assembly, adjustable entrance slit, and interchangeable detector holders to tune the trade-off between energy range, spectral resolution, and signal throughput. Three-dimensional magnetic fields calculated with Radia are benchmarked against Hall probe measurements and used in relativistic particle-tracing calculations to generate energy–position calibration curves for multiple detector and magnet geometries. In the configuration fielded at the Titan laser facility, the spectrometer provides electron spectral coverage from ∼125 keV to 70 MeV. Initial measurements from short-pulse irradiation of Cu wire targets show broadband electron spectra with MeV-scale effective temperatures. These results demonstrate the sensitivity of AMPS as a flexible diagnostic for resolving hot-electron distributions over a broad energy range suitable for relativistic short-pulse laser experiments. Future upgrades toward scintillator-based, high-repetition-rate operation are discussed.