Jirawat Swangsri

Jirawat Swangsri

Auto-generated profile, based on publicly available information

Jirawat Swangsri

Department of Surgery, Faculty of Medicine Siriraj Hospital, Mahidol University, Bangkok, Thailand

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 August 2022 in Clinical Endoscopy
Verified
Journal Article
Open access
PDF file
CNChawisa Nampoolsuksan
Chawisa Nampoolsuksan
VCVitoon Chinswangwatanakul
Vitoon Chinswangwatanakul
AMAsada Methasate
Asada Methasate
JSJirawat Swangsri
Jirawat Swangsri
ATAtthaphorn Trakarnsanga
Atthaphorn Trakarnsanga
TAThawatchai Akaraviputh
Thawatchai Akaraviputh
In the highly contagious coronavirus disease 2019 pandemic, aerosol-generating procedures (AGPs) are associated with high-risk of transmission. Upper gastrointestinal endoscopy is a procedure with the potential to cause dissemination of bodily fluids. At present, there is no consensus that endoscopy is defined as an AGP. This review discusses the current evidence on this topic with additional management. Prevailing publications on coronavirus related to upper gastrointestinal endoscopy and aerosolization from the PubMed and Scopus databases were searched and reviewed. Comparative quantitative analyses showed a significant elevation of particle numbers, implying that aerosols were generated by upper gastrointestinal endoscopy. The associated source events have also been reported. To reduce the dispersion, certain protective measures have been developed. Endoscopic unit protocols are recommended for the concerned personnel. Therefore, upper gastrointestinal endoscopy should be classified as an AGP. Proper practices should be adopted by healthcare workers and patients.

15 September 2026 in Journal of Minimally Invasive Surgery
Verified
Journal Article
Open access
PDF file
CTChatbadin Thongchuam
Chatbadin Thongchuam
CPChainarong Phalanusitthepha
Chainarong Phalanusitthepha
VCVitoon Chinswangwatanakul
Vitoon Chinswangwatanakul
TAThawatchai Akaraviputh
Thawatchai Akaraviputh
AMAsada Methasate
Asada Methasate
TSTharathorn Suwatthanarak
Tharathorn Suwatthanarak
Chatbadin Thongchuam, Chainarong Phalanusitthepha, Vitoon Chinswangwatanakul, Thawatchai Akaraviputh, Asada Methasate, Jirawat Swangsri, Tharathorn Suwatthanarak. Journal of Minimally Invasive Surgery 2026;29:158-62. https://doi.org/10.7602/jmis.2026.29.3.158


30 May 2024 in Clinical Endoscopy
Verified
Journal Article
Open access
PDF file
CNChawisa Nampoolsuksan
Chawisa Nampoolsuksan
TAThawatchai Akaraviputh
Thawatchai Akaraviputh
AMAsada Methasate
Asada Methasate
JSJirawat Swangsri
Jirawat Swangsri
ATAtthaphorn Trakarnsanga
Atthaphorn Trakarnsanga
VCVitoon Chinswangwatanakul
Vitoon Chinswangwatanakul
Background/Aims: The coronavirus disease 2019 pandemic has affected the worldwide practice of upper gastrointestinal endoscopy. Here we designed a modified N95 respirator with a channel for endoscope insertion and evaluated its efficacy in upper gastrointestinal endoscopy.Methods: Thirty patients scheduled for upper gastrointestinal endoscopy were randomized into the modified N95 (n=15) or control (n=15) group. The mask was placed on the patient after anesthesia administration and particles were counted every minute before (baseline) and during the procedure by a TSI AeroTrak particle counter (9306-04; TSI Inc.) and categorized by size (0.3, 0.5, 1, 3, 5, and 10 µm). Differences in particle counts between time points were recorded.Results: During the procedure, the modified N95 group displayed significantly smaller overall particle sizes than the control group (median [interquartile range], 231 [54–385] vs. 579 [213–1,379]×103/m3; p=0.056). However, the intervention group had a significant decrease in 0.3-µm particles (68 [–25–185] vs. 242 [72–588]×103/m3; p=0.045). No adverse events occurred in either group. The device did not cause any inconvenience to the endoscopists or patients.Conclusions: This modified N95 respirator reduced the number of particles, especially 0.3-µm particles, generated during upper gastrointestinal endoscopy.