Asnate Plocina

Asnate Plocina

Auto-generated profile, based on publicly available information

Asnate Plocina

ISAE-SUPAERO, Universit de Toulouse, Toulouse, France

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 April 2025 in IEEE Transactions on Nuclear Science
Verified
Journal Article
Closed access
APAsnate Plocina
Asnate Plocina
VGVincent Goiffon
Vincent Goiffon
OMOlivier Marcelot
Olivier Marcelot
DMDenis Marchais
Denis Marchais
OSOlivier Saint-Pé
Olivier Saint-Pé
AAAubin Antonsanti
Aubin Antonsanti
The European Space Agency’s (ESA) Aeolus mission utilized a space-based light detection and ranging (LiDAR) instrument for atmospheric wind measurements. These measurements were derived from signals collected by accumulation charge-coupled Devices (ACCDs), which showed unexpected behavior in flight. During the nearly five-year operation of the exploratory mission, hot pixels in the silicon detectors appeared at an almost-linear rate, most of which exhibited random telegraph signal (RTS) behavior, contrary to predictions based on pre-flight testing. The discrepancy highlights a gap between ground-based radiation tests, typically conducted at room temperature, and in-flight silicon detector conditions of low temperature and low readout noise levels. In-flight dark current activation energies and RTS phenomena observed in ACCD pixels are analysed, including suspected electric field enhancement (EFE) effects. This study compares these in-flight anomalies with literature models that forecast displacement damage dose (DDD)-induced dark current rates to determine if space radiation effects could be the primary cause of the hot pixels.

9 February 2026 in IEEE Transactions on Nuclear Science
Verified
Journal Article
Closed access
APAsnate Plocina
Asnate Plocina
AAAntoine Salih Alj
Antoine Salih Alj
VGVincent Goiffon
Vincent Goiffon
OMOlivier Marcelot
Olivier Marcelot
DMDenis Marchais
Denis Marchais
JPJérôme Pratlong
Jérôme Pratlong
Radiation testing and annealing of silicon-based detectors at room temperature are well established in the literature, whereas data on irradiation and subsequent annealing at low temperatures remain limited. This study examines proton irradiation effects at −30°C on accumulation charge-coupled devices (ACCDs), up to a displacement damage dose (DDD) of 337.16 TeV/g and a total ionizing dose (TID) of 13.59 krad(Si), followed by extended low-temperature annealing over 6.5 months. Key parameters such as dark current, activation energies, random telegraph signal (RTS) and annealing factors are explored and compared between ACCDs that have been irradiated and annealed both at room temperature and under flight-representative low-temperature conditions. Since silicon detectors in space are typically operated at low temperatures to reduce dark current and improve performance, this study highlights that defect formation and behaviour differ between room-temperature and low-temperature irradiation and annealing, demonstrating that on-ground room-temperature testing may not fully capture defect dynamics relevant to space environments and stressing the significant role of biasing during low-temperature irradiation.