Haiyan Pan

Haiyan Pan

Auto-generated profile, based on publicly available information

Haiyan Pan

Guangdong Medical University

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 July 2022 in IEEE Journal of Selected Topics in Applied Earth Observations and Remote Sensing
Verified
Journal Article
Open access
Zhonghua HongZhonghua Hong
Zhonghua Hong
ZLZhupeng Li
Zhupeng Li
XTXiaohua Tong
Xiaohua Tong
HPHaiyan Pan
Haiyan Pan
RZRuyan Zhou
Ruyan Zhou
ZMZhenling Ma
Zhenling Ma
Accurate recognition of circular marks is crucial for calibration, object tracking, and three-dimensional reconstruction in videogrammetry. However, most existing studies were designed under single or relatively simple scenes. When the existing algorithms are applied to more complex scenarios, it will result in higher false detection and miss-detection rate. In this article, we present a high-precision recognition method based on a novel deep learning model, circular-MarkNet (CMNet) to solve this problem. The proposed network consists of three main steps: first, circular marks are detected using the improved YOLOv4 model to narrow the search region of the circular contour; the contour of the circular marks is then extracted based on the saliency object detection model BASNet; and finally, least square fitting is used to calculate the central pixel coordinate of the identified contour on the saliency map. The proposed method was tested under three complex scenarios with different characteristics and disturbances. The experimental results demonstrated that: the proposed CMNet can effectively recognize of circular marks within complex scenes, which reveals the superiority and generalization ability of the proposed method; the improved YOLOv4 can significantly enhance the detection accuracy of circular marks, which is crucial to the subsequent saliency courter detection and circle center identification; and CMNet achieved the best performance, with an RMSE of 0.0713 pixel, compared to the state-of-the-art methods.

12 November 2021 in Journal of Cardiothoracic Surgery
Verified
Journal Article
Open access
PDF file
XWXiaowei Wang
Xiaowei Wang
YWYanbo Wang
Yanbo Wang
HPHaiyan Pan
Haiyan Pan
CYCi Yan
Ci Yan
Objective: Dimethyl fumarate (DMF) has been reported to exert a protective role against diverse lung diseases and cognitive impairment-related diseases. Thus this study aimed to investigate its role on acute lung injury (ALI) and related cognitive impairment in animal model. Methods: C57BL/6 mice were divided into four groups: control group, DMF group, ALI group, and ALI + DMF group. For ALI group, the ALI mice model was created by airway injection of LPS (50 μL, 1 μg/μL); for ALI + DMF group, DMF (dissolved in 0.08% methylcellulose) was treated twice a day for 2 days, and on the third day, mice were injected with LPS for ALI modeling. Mice pre-administered with methylcellulose or DMF without LPS injection (PBS instead) were used as the control group and DMF group, respectively. Morris water maze test was performed before any treatment (0 h) and 6 h after LPS-induction (54 h) to evaluate the cognitive impairment of mice. Next, the brain edema and blood brain barrier (BBB) permeability of ALI mice were assessed by brain water content, Evans blue extravasation and FITC-Dextran uptake assays. In addition, the effect of DMF on the numbers of total cells and neutrophils, protein content in BALF were quantified; the inflammatory factors in BALF, serum, and brain tissues were examined by ELISA, qRT-PCR, and Western blot assays. The effect of DMF on the cognitive impairment-related factor HIF-1α level in lung and brain tissues was also examined by Western blot. Results: DMF reduced the numbers of total cells, neutrophils and protein content in BALF of ALI mice, inhibited the levels of IL-6, TNF-α and IL-1β in BALF, serum and brain tissues of ALI mice. The protein expressions of p-NF-κB/NF-κB and p-IKBα/IKBα was also suppressed by DMF in ALI mice. Morris water maze test showed that DMF alleviated the cognitive impairment in ALI mice by reducing the escape latency and path length. Moreover, DMF lessened the BBB permeability by decreasing cerebral water content, Evans blue extravasation and FITC-Dextran uptake in ALI mice. The HIF-1α levels in lung and brain tissues of ALI mice were also lessened by DMF. Conclusion: In conclusion, DME had the ability to alleviate the lung injury and cerebral cognitive impairment in ALI model mice. This protective effect partly associated with the suppression of inflammation by DMF.

31 January 2024
Verified
Preprint
Open access
QLQiongling Liu
Qiongling Liu
XLXu Liu
Xu Liu
XXXiaohua Xie
Xiaohua Xie
CWChonghua Wan
Chonghua Wan
XZXingshan Zhang
Xingshan Zhang
HPHaiyan Pan
Haiyan Pan
Objective: To develop and assess the Quality of Life Instruments for Chronic Diseases-Gout (QLICD-GO [V2.0]). Methods: The instrument was developed using a programmatic decision-making method to combine the general module of the Quality of Life Instruments for Chronic Diseases and a new specific module. The instrument was assessed by measuring the quality of life of 116 patients with gout. Results: The QLICD-GO (V2.0) included 28 items from the general module of chronic diseases and 12 items in three facets from the specific module. In addition to the field of physiological function, the internal consistency reliability of other fields and dimensions of the instrument was >0.7 and the split-half reliability was >0.5. Three common factors were extracted from the specific module, with a cumulative variance contribution rate of 57.54%. The standardized response means of the specific module and the whole instrument were 0.94 and 1.20, respectively. Conclusions: The QLICD-GO (V2.0) has good reliability, validity, and responsiveness. The instrument comprehensively and objectively reflects the quality of life of patients with gout, and it can be used to assess treatment regimens developed by medical staff.

16 December 2020 in Research Square
Verified
Preprint
Open access
PDF file
QLQiongling Liu
Qiongling Liu
CWChonghua Wan
Chonghua Wan
XXXiaohua Xie
Xiaohua Xie
XLXu Liu
Xu Liu
XZXingshan Zhang
Xingshan Zhang
HPHaiyan Pan
Haiyan Pan
Background: To develop and assess the Quality of Life Instruments for Chronic Diseases-Gout (QLICD-GO [V2.0]).Methods: The instrument was developed using a programmatic decision-making method to combine the general module of the Quality of Life Instruments for Chronic Diseases and a new specific module. The instrument was assessed by measuring the quality of life of 116 patients with gout. Results: The QLICD-GO(V2.0) included 28 items from the general module of chronic diseases and 12 items in three facets from the specific module. In addition to the field of physiological function, the internal consistency reliability of other fields and dimensions of the instrument was >0.7 and the split-half reliability was >0.5. Three common factors were extracted from the specific module, with a cumulative variance contribution rate of 57.54%. The standardized response means of the specific module and the whole instrument were 0.94 and 1.20, respectively. Conclusions: The QLICD-GO(V2.0) has good reliability, validity, and responsiveness. The instrument comprehensively and objectively reflects the quality of life of patients with gout, and it can be used to assess treatment regimens developed by medical staff.

29 May 2020 in Research Square
Verified
Preprint
Open access
PDF file
QLQiongling Liu
Qiongling Liu
CWChonghua Wan
Chonghua Wan
XXXiaohua Xie
Xiaohua Xie
XLXu Liu
Xu Liu
XZXingshan Zhang
Xingshan Zhang
HPHaiyan Pan
Haiyan Pan
Objective To develop and assess the Quality of Life Instruments for Chronic Diseases-Gout (QLICD-GO [V2.0]).Methods The instrument was developed using a programmatic decision-making method to combine the general module of the Quality of Life Instruments for Chronic Diseases and a new specific module. The instrument was assessed by measuring the quality of life of 116 patients with gout.Results The QLICD-GO(V2.0) included 28 items from the general module of chronic diseases and 12 items in three facets from the specific module. In addition to the field of physiological function, the internal consistency reliability of other fields and dimensions of the instrument was > 0.7 and the split-half reliability was > 0.5. Three common factors were extracted from the specific module, with a cumulative variance contribution rate of 57.54%. The standardized response means of the specific module and the whole instrument were 0.94 and 1.20, respectively.Conclusions The QLICD-GO(V2.0) has good reliability, validity, and responsiveness. The instrument comprehensively and objectively reflects the quality of life of patients with gout, and it can be used to assess treatment regimens developed by medical staff.