22 May 2020 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
JZJun Zhong
Jun Zhong
XBXiaowen Bi
Xiaowen Bi
QSQin Shu
Qin Shu
MCMinwei Chen
Minwei Chen
DZDianbo Zhou
Dianbo Zhou
DZDakun Zhang
Dakun Zhang
Online partial discharge (PD) monitoring is an im-portant means to detect insulation deterioration. However, it is dif-ficult to extract PD signal due to various interference in the field. Noisy PD signal is used to judge the status of insulation, which would affect the conclusion, therefore de-noising PD signal is a ma-jor task in online PD monitoring. Common methods for PD de-noising include the empirical mode decomposition (EMD) and wavelet transform; however, the de-noising results are highly de-pendent on the modal aliasing, the selection of mother wavelets and decomposition levels. This paper proposes a method to solve these problems. This method uses traditionally singular value transform (SVD) to reconstruct narrow-band interference and re-move it. Next, the empirical wavelet transform (EWT) is carried out for the PD signal which has residual white noise. Then, the noisy signal is decomposed into several modes corresponding to each spectrum segment. 3σ principle is used to de-noise the modes with large kurtosis, and the modes are combined into a reference signal. The start-end positions of PD signal are then obtained from the reference signal. Finally, the PD signal is obtained by time-do-main de-noising. The results from both simulated and actual field detection signals show the excellent performance of this method.

14 April 2021 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
JZJun Zhong
Jun Zhong
XBXiaowen Bi
Xiaowen Bi
QSQin Shu
Qin Shu
DZDakun Zhang
Dakun Zhang
XLXiaopeng Li
Xiaopeng Li
Due to complex disturbance environment, partial discharge (PD) monitor signal denoising is a necessary step to judge the state of equipment insulation. In the denoising process, it is difficult to suppress the white noise due to its wide frequency-domain distribution. To overcome these difficulties, most denoising algorithms need to artificially adjust some threshold parameters or select the number of decomposition layers according to the measured PD signals, which leads to the confusion of uncertainty, and the denoising performance depends on the parameter setting experience. Therefore, the denoising effect cannot be guaranteed in general. This article proposes a method without human intervention in choosing the threshold parameters or the decomposition layer numbers. First, the decomposition layers are directly determined from the spectral kurtogram of PD signal to obtain the reference signal. Second, the reference signal is denoised by 3σ threshold. At the start point obtained from the denoised signal and the end point obtained from the reference signal envelope, the reference signal is segmented in the time domain to obtain the final denoising PD signal. The denoising results of both the simulated and field-measured PD signals show that the proposed method can effectively remove the white noise and recover PD signal more accurately.

5 January 2021 in IEEE Access
Verified
Journal Article
Open access
XYXiaoli Yang
Xiaoli Yang
HHHongguang Huang
Hongguang Huang
QSQin Shu
Qin Shu
DZDakun Zhang
Dakun Zhang
BCBojian Chen
Bojian Chen
The detection process of partial discharge (PD) ultra-high frequency (UHF) signal is easily affected by white noise and periodic narrowband noise, which hinder the fault diagnosis of high-voltage electrical appliances. In order to extract PD UHF signal and suppress noise effectively, this paper provides a new method to detect PD UHF signal by EDSSV and low rank RBF neural network. Firstly, the singular value decomposition (SVD) is performed on the mixed noises of PD signal. Secondly, the peak index of energy difference spectrum of singular value (EDSSV) is selected as optimal singular value threshold, and then the periodic narrowband noise is eliminated by reconstructing the effective rank order. Finally, radial basis function (RBF) neural network is used to approximate the denoised PD signal, and Gaussian window filter is used to extract the PD signal. To verify the performance of the proposed method, we compared it with other three algorithms in simulation and field detection, including adaptive singular value decomposition (ASVD), singular value decomposition based on S-transform and MTFM (S-SVD) and EMD-WT algorithms. Particularly, four evaluation indices are designed for the detection data, which consider both the noise suppression and feature preservation. The results demonstrate the validity of the proposed method with higher signal-to-noise ratio and less waveform distortion.

8 September 2021 in IET Science, Measurement & Technology
Verified
Journal Article
Open access
PDF file
CWChang Wang
Chang Wang
CYChunxiao Yu
Chunxiao Yu
QSQin Shu
Qin Shu
DZDakun Zhang
Dakun Zhang
YHYuhang He
Yuhang He
On‐line partial discharge (PD) monitoring is related to the safe and stable operation of power grid. However, the measured signal is inevitably affected by noise. Among a variety of noises, white noise is the most difficult to suppress and ubiquitous. It mainly determines the Cramer–Rao lower bound that cannot be crossed by all methods. This article proposes the Prony time‐series energy spectrum method to suppress white noise in a low signal‐to‐noise ratio environment. This method is divided into two parts: First, Prony time series energy spectrum is used to detect whether there is PD signals in the measured signal. Then, based on the least square method, the PD signal is estimated with the Prony model. In data analysis, this method can suppress ‐10dB white noise, while other methods have performed poorly or even failed under the same conditions. In general, this method has excellent anti‐noise performance compared to several other algorithms.