1 April 2021 in Radiotherapy and Oncology
Verified
Journal Article
Open access
LDLaurence Delombaerde
Laurence Delombaerde
SPSaskia Petillion
Saskia Petillion
CWCaroline Weltens
Caroline Weltens
TDTom Depuydt
Tom Depuydt
Fast rotating closed-bore gantry linacs are ideally suited for breath-hold treatments due to reduced imaging and delivery times. We evaluated the reproducibility and stability of spirometer-guided breath-hold breast treatments, using intra-bore surface monitoring and portal imaging on Halcyon (Varian Medical Systems). Seven left-sided breast cancer patients were treated in breath-hold using the SDX spirometer (Dyn'R) with an integrated boost volumetric arc protocol on Halcyon. A dual depth-camera surface scanning system monitored the left breast. The interfraction, intrafraction and intrabreath-hold motion was determined in the anterior-posterior (AP) and superior-inferior (SI) direction. Portal images (PI), acquired at a tangential gantry angle were manually registered to the planning-CT to determine inter- and intrafraction breath-hold errors for the SI and tangential-anterior-posterior ("AP") axis. Correlations between PI and surface imaging deviations were investigated. To evaluate workflow efficiency, the total time and the number of breath-holds were recorded. Systematic and random variability of breath-hold amplitude was below 0.7 mm for the AP and below 1.2 mm for the SI component as detected by surface monitoring (N = 130). Systematic and random errors retrieved from portal images (N = 140) were below 1.2 mm for the "AP" and 2.1 mm for SI axis. A limited correlation was found between PI and surface monitoring deviations for both the SI and "AP" axes (R2 = 0.27/0.38, p < 0.01). 75% of fractions were completed using four breath-holds and 82% within 10 min. Surface imaging indicated spirometer-guided breath-hold VMAT breast radiotherapy can be accurately and quickly performed on a closed-bore gantry linac. Intra-bore surface scanning proved a valuable technique for monitoring breathing motion in closed-bore systems.

30 October 2021 in Physics and Imaging in Radiation Oncology
Verified
Journal Article
Open access
LDLaurence Delombaerde
Laurence Delombaerde
SPSaskia Petillion
Saskia Petillion
CWCaroline Weltens
Caroline Weltens
TDTom Depuydt
Tom Depuydt
New closed-bore linacs allow for highly streamlined workflows and fast treatment delivery resulting in brief treatment sessions. Motion management technology has only recently been integrated inside the bore, yet is required in future online adaptive workflows. We measured patient motion during every step of the workflow: image acquisition, evaluation and treatment delivery using surface scanning. Nineteen patients treated for breast, lung or esophageal cancer were prospectively monitored from the end of setup to the end of treatment delivery in the Halcyon linac (Varian Medical Systems). Motion of the chest was tracked by way of 6 degrees-of-freedom surface tracking. Baseline drift and rate of drift were determined. The influence of fraction number, patient and fraction duration were analyzed with multi-way ANOVA. Median fraction duration was 4 min 48 s including the IGRT procedure (kV-CBCT acquisition and evaluation) (N = 221). Baseline drift at the end of the fraction was −1.8 ± 1.5 mm in the anterior-posterior, −0.0 ± 1.7 mm in the cranio-caudal direction and 0.1 ± 1.8 mm in the medio-lateral direction of which 75% occurred during the IGRT procedure. The highest rate of baseline drift was observed between 1 and 2 min after the end of patient setup (-0.62 mm/min). Baseline drift was patient and fraction duration dependent (p < 0.001), but fraction number was not significant (p = 0.33). Even during short treatment sessions, patient baseline drift is not negligible. Drift is largest during the initial minutes after completion of patient setup, during verification imaging and evaluation. Patients will need to be monitored during extended contouring and re-planning procedures in online adaptive workflows.

1 July 2019 in Physics and Imaging in Radiation Oncology
Verified
Journal Article
Open access
LDLaurence Delombaerde
Laurence Delombaerde
SPSaskia Petillion
Saskia Petillion
SMSteven Michiels
Steven Michiels
CWCaroline Weltens
Caroline Weltens
TDTom Depuydt
Tom Depuydt
Current commercial surface scanning systems are not able to monitor patients during radiotherapy fractions in closed-bore linacs during adaptive workflows. In this work a surface scanning system for monitoring in an O-ring linac is proposed. A depth camera was mounted at the backend of the bore. The acquired surface point cloud was transformed to the linac coordinate system after a cube detection calibration step. The real-time surface was registered using an Iterative Closest Point algorithm to a reference region-of-interest of the body contour from the planning CT and of a depth camera surface acquisition from the first fraction. The positioning accuracy was investigated using anthropomorphic 3D-printed phantoms with embedded markers: a head, hand and breast. To simulate clinically observed positioning errors, each phantom was placed 24 times with 0–10 mm and 0–8° offsets from the planned position. At every position a cone-beam CT (CBCT) was acquired and a surface registration performed. The surface registration error was determined as the difference between the surface registration and the CBCT-to-CT fiducial marker registration. The registration errors were (mean ± SD): lat: 0.4 ± 0.8 mm, vert: −0.2 ± 0.2 mm, long: 0.3 ± 0.5 mm and Yaw: −0.2 ± 0.6°, Pitch: 0.4 ± 0.2°, Roll: 0.5 ± 0.8° for the body contour reference, and lat: −0.7 ± 0.7 mm, vert: 0.3 ± 0.2 mm, long: 0.2 ± 0.5 mm and Yaw: −0.5 ± 0.5°, Pitch: 0.1 ± 0.3°, Roll: −0.7 ± 0.7° for the captured surface reference. The proposed single camera intra-bore surface system was capable of accurately detecting phantom displacements and allows intrafraction motion monitoring for surface guided radiotherapy inside the bore of O-ring gantries.

15 August 2020 in Journal of Applied Clinical Medical Physics
Verified
Journal Article
Open access
PDF file
LDLaurence Delombaerde
Laurence Delombaerde
SPSaskia Petillion
Saskia Petillion
CWCaroline Weltens
Caroline Weltens
RRRobin De Roover
Robin De Roover
TRTruus Reynders
Truus Reynders
TDTom Depuydt
Tom Depuydt
End‐to‐end testing of a new breast radiotherapy technique preferably requires realistic phantom geometries, which is challenging to achieve using currently commercially available solutions. We have developed a series of three‐dimensional (3D)‐printed breast phantoms, with ionization chamber and radiochromic film inserts, which can be attached to a commercial anthropomorphic thorax phantom. A contoured left breast from a patient’s planning CT was mapped onto a CT of the CIRS E2E thorax phantom (CIRS Inc.) and cropped to fit the surface. Four versions of the breast were 3D printed, containing a cavity for an ionization chamber and slits for radiochromic film insertion in the three cardinal planes, respectively. The phantoms were fully compatible with surface scanning technology used for setup. The phantoms were validated using a whole‐breast volumetric modulated arc therapy protocol with a simultaneous integrated boost to the tumor bed (VMAT‐SIB). Six patient plans and one original plan on the breast phantom were verified with planar portal imaging, point dose, and film measurements in the MultiCube phantom and planar γ‐analysis using ArcCHECK diode array. Six patient plans were recalculated on the breast phantom (hybrid plans) and delivered with point dose and film measurements with 3% (local)/2 mm γ‐analysis. One complete end‐to‐end test on the breast phantom was performed. All plan quality verifications had point dose differences below 2.4% from the calculated dose and γ‐agreement scores (γAS) > 87.3% for film measurements in the MultiCube, portal dosimetry, and ArcCHECK. Point dose differences in the 3D‐printed phantoms were below 2.6% (median −1.4%, range −2.6%; 0.3%). Median γAS was 96.4% (range 80.1%–99.7%) for all film inserts. The proposed 3D‐printed attachable breast dosimetry phantoms have been shown to be a valuable tool for end‐to‐end testing of a new radiotherapy protocol. The workflow described in this report can aid users to create their own phantom‐specific breast 3D‐printed phantoms.

1 April 2018 in Radiotherapy and Oncology
Verified
Journal Article
Open access
LDL. Delombaerde
L. Delombaerde
SPS. Petillion
S. Petillion
TDT. Depuydt
T. Depuydt

22 November 2024 in Physics and Imaging in Radiation Oncology
Verified
Journal Article
Open access
LVLiesbeth Vandewinckele
Liesbeth Vandewinckele
CBChahrazad Benazzouz
Chahrazad Benazzouz
LDLaurence Delombaerde
Laurence Delombaerde
LPLaure Pape
Laure Pape
TRTruus Reynders
Truus Reynders
WCWouter Crijns
Wouter Crijns
Background and Purpose: With the increasing amount of in-house created deep learning models in radiotherapy, it is important to know how to minimise the risks associated with the local clinical implementation prior to clinical use. The goal of this study is to give an example of how to identify the risks and find mitigation strategies to reduce these risks in an implemented workflow containing a deep learning based planning tool for breast Volumetric Modulated Arc Therapy. Materials and Methods: The deep learning model ran on a private Google Cloud environment for adequate computational capacity and was integrated into a workflow that could be initiated within the clinical Treatment Planning System (TPS). A proactive Failure Mode and Effect Analysis (FMEA) was conducted by a multidisciplinary team, including physicians, physicists, dosimetrists, technologists, quality managers, and the research and development team. Failure modes categorised as 'Not acceptable' and 'Tolerable' on the risk matrix were further examined to find mitigation strategies. Results: In total, 39 failure modes were defined for the total workflow, divided over four steps. Of these, 33 were deemed 'Acceptable', five 'Tolerable', and one 'Not acceptable'. Mitigation strategies, such as a casespecific Quality Assurance report, additional scripted checks and properties, a pop-up window, and time stamp analysis, reduced the failure modes to two 'Tolerable' and none in the 'Not acceptable' region. Conclusions: The pro-active risk analysis revealed possible risks in the implemented workflow and led to the implementation of mitigation strategies that decreased the risk scores for safer clinical use.