11 February 2022 in The Annals of Thoracic Surgery
19 August 2022 in Acta Biomaterialia
24 February 2022 in JTCVS Open
To complete the first in-human study of the automated line clearance Thoraguard chest tube system. The study focuses on the viability and efficacy of the device in comparison with conventional models as well as secondary matters such as patient experience and ease of use. This was a single-center, prospective, open-label study involving adult patients (n = 27) who underwent nonemergent, first-time, cardiac surgery. Patients received automated clearance chest tubes for surgical drainage in both the mediastinal and pleural spaces. The control group was retrospective (n = 80); individuals received conventional chest tubes placed and secured in locations determined at the surgeon's discretion. The automated-clearance tubes exhibited a similar drainage profile at 1, 3, 6, 12, and 24 hours compared with the conventional chest tubes. The final output at the time of tube removal was also similar (1150 [750-1590] vs 1289 [766.3-1890] mL, respectively, P = .76). The number of patients readmitted for drainage of an effusion was similar in both groups (1/27 [3.7%] vs 3/80 [3.75%], P > .99). This study has shown that the Centese Thoraguard chest tube system is a viable option for surgical chest drainage and effective when used in routine cardiac surgery operations.
14 February 2023 in PLOS ONE
Objective: Analyze changes in frequency activity and structural organization that occur over time with persistent atrial fibrillation (AF) Background: Little is known about the frequency characteristics of the epicardium during transition from paroxysmal to persistent AF. Accurate identification of areas of high dominant frequency (DF) is often hampered by limited spatial resolution. Improvements in electrode arrays provide high spatiotemporal resolution, allowing for characterization of the changes that occur during this transition. Methods: AF was induced in adult Yorkshire swine by atrial tachypacing. DF mapping was performed using personalized mapping arrays. Histological analysis and late gadolinium enhanced magnetic resonance imaging were performed to determine structural differences in fibrosis. Results: The left atrial epicardium was associated with a significant increase in DF in persistent AF (6.5 ± 0.2 vs. 7.4 ± 0.5 Hz, P = 0.03). The organization index (OI) significantly decreased during persistent AF in both the left atria (0.3 ± 0.03 vs. 0.2 ± 0.03, P = 0.01) and right atria (0.33 ± 0.04 vs. 0.23 ± 0.02, P = 0.02). MRI analysis demonstrated increased ECV values in persistent AF (0.19 vs 0.34, paroxysmal vs persistent, P = 0.05). Tissue sections from the atria showed increase in fibrosis in pigs with persistent AF compared to paroxysmal AF. Staining demonstrated decreased myocardial fiber alignment and loss of anisotropy in persistent AF tissue. Conclusions: Changes in tissue organization and fibrosis are observed in the porcine model of persistent AF. Alterations in frequency activity and organization index can be captured with high resolution using flexible electrode arrays.