7 December 2020 in IEEE Transactions on Control Systems Technology
Hierarchical architectures stacking primary, secondary, and tertiary layers are widely employed for the operation and control of islanded dc microgrids (dcmGs) composed of distribution generation units (DGUs), loads, and power lines. However, a comprehensive analysis of all the layers put together is often missing. In this work, we remedy this limitation by setting out a top-to-bottom hierarchical control architecture. Decentralized voltage controllers attached to DGUs form our primary layer. Governed by an MPC-based energy management system (EMS), our tertiary layer generates optimal power references and decision variables for DGUs. In particular, decision variables can turn DGUs on/off and select their operation modes. An intermediary secondary layer translates EMS power references into appropriate voltage signals required by the primary layer. More specifically, to provide a voltage solution, the secondary layer solves an optimization problem embedding power-flow equations shown to be always solvable. Since load voltages are not directly enforced, their uniqueness is necessary for DGUs to produce reference powers handed down by the EMS. To this aim, we deduce a novel uniqueness condition based only on local load parameters. Our control framework, besides being applicable for generic dcmG topologies, can accommodate topological changes caused by EMS commands. Its functioning is validated via simulations on a modified 16-bus dc system.
10 November 2021 in IEEE Transactions on Control Systems Technology
In this work, we present a novel consensus-based secondary control scheme for current sharing and voltage balancing in dc microgrids (DCmGs), composed of distributed generation units (DGUs), dynamic RLC lines, and nonlinear ZIE (constant impedance, constant current, and exponential) loads. Situated atop a primary voltage control layer, our secondary controllers have a distributed structure and utilize information exchanged over a communication network to compute necessary control actions. Besides showing that the desired objectives are always attained in steady state, we deduce sufficient conditions for the existence and uniqueness of an equilibrium point for constant power loads— $E$ loads with zero exponent. Our control design hinges only on the local parameters of the generation units, facilitating plug-and-play operations. We provide a voltage stability analysis and illustrate the performance and robustness of our designs via simulations. All results hold for arbitrary, albeit connected, mG and communication network topologies.
22 October 2021 in IEEE Transactions on Control Systems Technology
The increasing penetration of intermittent distributed energy resources in power networks calls for novel planning and control methodologies which hinge on detailed knowledge of the grid. However, reliable information concerning the system topology and parameters may be missing or outdated for temporally varying electric distribution networks. This brief proposes an online learning procedure to estimate the network admittance matrix capturing topological information and line parameters. We start off by providing a recursive identification algorithm exploiting phasor measurements of voltages and currents. With the goal of accelerating convergence, we subsequently complement our base algorithm with a design-of-experiment procedure which maximizes the information content of data at each step by computing optimal voltage excitations. Our approach improves on existing techniques, and its effectiveness is substantiated by numerical studies on a modified IEEE testbed.
4 October 2022 in IEEE Transactions on Smart Grid
The increasing integration of renewable energy requires a good model of the existing power distribution infrastructure, represented by its admittance matrix. However, a reliable estimate may either be missing or quickly become obsolete, as distribution grids are continuously modified. In this work, we propose a method for estimating the admittance matrix from voltage and current measurements. By focusing on $\mu $ PMU measurements and partially observed networks, we show that voltage collinearity and noisy samples of all electric variables are the main challenges for accurate identification. Moreover, the accuracy of maximum likelihood estimation is often insufficient in real-world scenarios. To overcome this problem, we develop a flexible Bayesian framework that allows one to exploit different forms of prior knowledge about individual line parameters, as well as network-wide characteristics such as the sparsity of the interconnections. Most importantly, we show how to use maximum likelihood estimates for tuning relevant hyperparameters, hence making the identification procedure self-contained. We also discuss numerical aspects of the maximum a posteriori estimate computation. Realistic simulations conducted on benchmark electrical systems demonstrate that, compared to other algorithms, our method can achieve significantly greater accuracy than previously developed methods.
31 December 2021 in IEEE Transactions on Control Systems Technology
Voltage and frequency control in an islanded ac microgrid (ImG) amounts to stabilizing an a priori unknown ImG equilibrium induced by loads and changes in topology. This article puts forth a unified control framework, which, while guaranteeing such stability, allows for modular ImGs interconnecting multiple subsystems, that is, dynamic $RLC$ lines, nonlinear constant impedance, current, power (ZIP) and exponential (EXP) loads, and inverter-based distributed generation units (DGUs) controlled with different types of primary controllers. The underlying idea of the framework is based on the equilibrium-independent passivity (EIP) of the ImG subsystems, which enables stability certificates of ImG equilibria without explicit knowledge of these equilibria. In order to render DGUs EIP, we propose a decentralized controller synthesis algorithm based on port-Hamiltonian systems (PHSs). We also show that EIP, being the key to stability, provides a general framework, which can embrace other solutions available in the literature. Furthermore, we provide a novel argument based on LaSalle’s theorem for proving asymptotic voltage and frequency stability. Finally, we analyze the impact of actuator saturation on the stability results by exploiting the inherent EIP properties of the PHS DGU model. Theoretical findings are backed up by realistic simulations based on the medium-voltage CIGRE benchmark network.
19 December 2021 in arXiv
The increasing integration of intermittent renewable generation, especially at the distribution level,necessitates advanced planning and optimisation methodologies contingent on the knowledge of thegrid, specifically the admittance matrix capturing the topology and line parameters of an electricnetwork. However, a reliable estimate of the admittance matrix may either be missing or quicklybecome obsolete for temporally varying grids. In this work, we propose a data-driven identificationmethod utilising voltage and current measurements collected from micro-PMUs. More precisely,we first present a maximum likelihood approach and then move towards a Bayesian framework,leveraging the principles of maximum a posteriori estimation. In contrast with most existing con-tributions, our approach not only factors in measurement noise on both voltage and current data,but is also capable of exploiting available a priori information such as sparsity patterns and knownline parameters. Simulations conducted on benchmark cases demonstrate that, compared to otheralgorithms, our method can achieve significantly greater accuracy.