Shyam Kishore Shrivastava

Shyam Kishore Shrivastava

Auto-generated profile, based on publicly available information

Shyam Kishore Shrivastava

Department of Radiation Oncology, Hcg-Ics Khubchandani Cancer Centre, Mumbai, India

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 August 2010 in Journal of Gastrointestinal Cancer
Verified
Journal Article
Closed access
PDF file
REReena Engineer
Reena Engineer
TWTabassum Wadasadawala
Tabassum Wadasadawala
SMShaesta Mehta
Shaesta Mehta
UMUmesh Mahantshetty
Umesh Mahantshetty
NPNilendu Purandare
Nilendu Purandare
SSShyam Kishore Shrivastava
Shyam Kishore Shrivastava

15 September 2023 in Brachytherapy
Verified
Journal Article
Closed access
UMUmesh Mahantshetty
Umesh Mahantshetty
SKSheetal R. Kashid
Sheetal R. Kashid
GMGargee Mulye
Gargee Mulye
LGLavanya Gurram
Lavanya Gurram
REReena Engineer
Reena Engineer
SSS.K. Shrivastava
S.K. Shrivastava

1 August 2019 in Clinical Oncology
Verified
Journal Article
Closed access
SCS. Chopra
S. Chopra
PMPrachi Mittal
Prachi Mittal
AVA. Viswanathan
A. Viswanathan
ETE. Tharavichitkul
E. Tharavichitkul
EZE. Zubizarreta
E. Zubizarreta
SSS.K. Shrivastava
S.K. Shrivastava

1 November 2021 in Brachytherapy
Verified
Journal Article
Closed access
UMUmesh Mahantshetty
Umesh Mahantshetty
SLShirley Lewis
Shirley Lewis
REReena Engineer
Reena Engineer
JSJamema Swamidas
Jamema Swamidas
SCSupriya Chopra
Supriya Chopra
SSShyamkishore Shrivastava
Shyamkishore Shrivastava

15 May 2023 in Brachytherapy
Verified
Journal Article
Closed access
PMPrachi Mittal
Prachi Mittal
SCSupriya Chopra
Supriya Chopra
MKMitchell Kamrava
Mitchell Kamrava
RVRajesh Vashistha
Rajesh Vashistha
SKStefan Konrad
Stefan Konrad
ASAlina Emiliana Sturdza
Alina Emiliana Sturdza

20 April 2013 in Bangladesh Journal of Medical Physics
Verified
Journal Article
Open access
PDF file
MAM Jahangir Alam
M Jahangir Alam
SHSyed Md Akram Hussain
Syed Md Akram Hussain
KAKamila Afroj
Kamila Afroj
SSShyam Kishore Shrivastava
Shyam Kishore Shrivastava
A three dimensional treatment planning system has been installed in the Oncology Center, Bangladesh. This system is based on the Anisotropic Analytical Algorithm (AAA). The aim of this study is to verify the validity of photon dose distribution which is calculated by this treatment planning system by comparing it with measured photon beam data in real water phantom. To do this verification, a quality assurance program, consisting of six tests, was performed. In this program, both the calculated output factors and dose at different conditions were compared with the measurement. As a result of that comparison, we found that the calculated output factor was in excellent agreement with the measured factors. Doses at depths beyond the depth of maximum dose calculated on-axis or off-axis in both the fields or penumbra region were found in good agreement with the measured dose under all conditions of energy, SSD and field size, for open and wedged fields. In the build up region, calculated and measured doses only agree (with a difference 2.0%) for field sizes > 5 × 5 cm2 up to 25 × 25 cm2. For smaller fields, the difference was higher than 2.0% because of the difficulty in dosimetry in that region. Dose calculation using treatment planning system based on the Anisotropic Analytical Algorithm (AAA) is accurate enough for clinical use except when calculating dose at depths above maximum dose for small field size.DOI: http://dx.doi.org/10.3329/bjmp.v4i1.14686 Bangladesh Journal of Medical Physics Vol.4 No.1 2011 43-49