Erica E. Neumann

Erica E. Neumann

Auto-generated profile, based on publicly available information

Erica E. Neumann

Department of Biomedical Engineering, Cleveland Clinic, Cleveland, Ohio, USA

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 November 2017 in Biomechanics and Modeling in Mechanobiology
Verified
Journal Article
Closed access
PDF file
CSChristina J. Stender
Christina J. Stender
EREvan Rust
Evan Rust
PMPeter T. Martin
Peter T. Martin
ENErica E. Neumann
Erica E. Neumann
RBRaquel J. Brown
Raquel J. Brown
TLTrevor J. Lujan
Trevor J. Lujan

1 January 2020 in Journal of the Mechanical Behavior of Biomedical Materials
Verified
Journal Article
Open access
CNChristopher Noble
Christopher Noble
KCKent D. Carlson
Kent D. Carlson
ENErica Neumann
Erica Neumann
DDDan Dragomir-Daescu
Dan Dragomir-Daescu
AEAhmet Erdemir
Ahmet Erdemir
MYMelissa Young
Melissa Young
Patient-specific finite element (FE) modeling of atherosclerotic plaque is challenging, as there is limited information available clinically to characterize plaque components. This study proposes that for the limited data available in vivo, material properties of plaque and artery can be identified using inverse FE analysis and either a simple neo-Hookean constitutive model or assuming linear elasticity provides sufficient accuracy to capture the changes in vessel deformation, which is the available clinical metric. To test this, 10 human cadaveric femoral arteries were each pressurized ex vivo at 6 pressure levels, while intravascular ultrasound (IVUS) and virtual histology (VH) imaging were performed during controlled pull-back to determine vessel geometry and plaque structure. The VH images were then utilized to construct FE models with heterogeneous material properties corresponding to the vessel plaque components. The constitutive models were then fit to each plaque component by minimizing the difference between the experimental and the simulated geometry using the inverse FE method. Additionally, we further simplified the analysis by assuming the vessel wall had a homogeneous structure, i.e. lumping artery and plaque as one tissue. We found that for the heterogeneous wall structure, the simulated and experimental vessel geometries compared well when the fitted neo-Hookean parameters or elastic modulus, in the case of linear elasticity, were utilized. Furthermore, taking the median of these fitted parameters then inputting these as plaque component mechanical properties in the finite element simulation yielded differences between simulated and experimental geometries that were on average around 2% greater (1.30-5.55% error range to 2.33-11.71% error range). For the homogeneous wall structure the simulated and experimental wall geometries had an average difference of around 4% although when the difference was calculated using the median fitted value this difference was larger than for the heterogeneous fits. Finally, comparison to uniaxial tension data and to literature constitutive models also gave confidence to the suitability of this simplified approach for patient-specific arterial simulation based on data that may be acquired in the clinic.

1 January 2019 in Journal of Biomechanics
Verified
Journal Article
Open access
TSTyler Schimmoeller
Tyler Schimmoeller
RCRobb Colbrunn
Robb Colbrunn
TNTara Nagle
Tara Nagle
MLMark Lobosky
Mark Lobosky
ENErica E. Neumann
Erica E. Neumann
AEAhmet Erdemir
Ahmet Erdemir
Ultrasound is a popular and affordable imaging modality, but the nature of freehand ultrasound operation leads to unknown applied loads at non-quantifiable angles. The purpose of this paper was to demonstrate an instrumentation strategy for an ultrasound system to measure probe forces and orientation during freehand imaging to characterize the interaction between the probe and soft-tissue as well as enhance repeatability. The instrumentation included a 6-axis load cell, an inertial measurement unit, and an optional sensor for camera-based motion capture. A known method for compensation of the ultrasound probe weight was implemented, and a novel method for temporal synchronization was developed. While load and optical sensing was previously achieved, this paper presents a strategy for potential instrumentation on a variety of ultrasound machines. A key feature was the temporal synchronization, utilizing the electrocardiogram (EKG) feature built-in to the ultrasound. The system was used to perform anatomical imaging of tissue layers of musculoskeletal extremities and imaging during indentation on an in vivo subject and an in vitro specimen. The outcomes of the instrumentation strategy were demonstrated during minimal force and indentation imaging. In short, the system presented robust instrumentation of an existing ultrasound system to fully characterize the probe force, orientation, and optionally its movement during imaging while efficiently synchronizing all data. Researchers may use the instrumentation strategy on any EKG capable ultrasound systems if mechanical characterization of soft tissue or minimization of forces and deformations of tissue during anatomical imaging are desired.

5 June 2018 in Annals of Biomedical Engineering
Verified
Journal Article
Closed access
PDF file
SFStephanie M. Frahs
Stephanie M. Frahs
Julia OxfordJulia Oxford
Julia Oxford
ENErica E. Neumann
Erica E. Neumann
RBRaquel J. Brown
Raquel J. Brown
CKCynthia R. Keller-Peck
Cynthia R. Keller-Peck
TLTrevor J. Lujan
Trevor J. Lujan

25 September 2018 in Scientific Data
Verified
Journal Article
Open access
PDF file
ENErica E. Neumann
Erica E. Neumann
TOTammy M. Owings
Tammy M. Owings
TSTyler Schimmoeller
Tyler Schimmoeller
TNTara F. Nagle
Tara F. Nagle
RCRobb W. Colbrunn
Robb W. Colbrunn
AEAhmet Erdemir
Ahmet Erdemir
Musculoskeletal extremities exhibit a multi-layer tissue structure that is composed of skin, fat, and muscle. Body composition and anthropometric measurements have been used to assess health status and build anatomically accurate biomechanical models of the limbs. However, comprehensive datasets inclusive of regional tissue anatomy and response under mechanical manipulation are missing. The goal of this study was to acquire and disseminate anatomical and mechanical data collected on extremities of the general population. An ultrasound system, instrumented with a load transducer, was used for in vivo characterization of skin, fat, and muscle thicknesses in the extremities of 100 subjects at unloaded (minimal force) and loaded (through indentation) states. For each subject, the unloaded and loaded state provided anatomic tissue layer measures and tissue indentation response for 48 and 8 regions, respectively. A publicly available web-based system has been used for data management and dissemination. This comprehensive database will provide the foundation for comparative studies in regional musculoskeletal composition and improve visual and haptic realism for computational models of the limbs.

1 October 2019 in Journal of Biomechanics
Verified
Journal Article
Closed access
ENErica E. Neumann
Erica E. Neumann
TOTammy M. Owings
Tammy M. Owings
AEAhmet Erdemir
Ahmet Erdemir