3 May 2015 in Applied Magnetic Resonance
10 January 2019 in Circulation Reports
Background: It is still unclear whether dynamic exercise increases the number of Muse cells, pluripotent stem cells, in the peripheral blood.
4 July 2018 in IEEE Journal of Translational Engineering in Health and Medicine
Precise dispensing of droplets is a crucial step for acquiring reliable blood diagnostic results. When the source sample volume is limited, the need for precise dispensing of submicroliter and nanoliter quantities is especially important. In this paper, we developed a positive-displacement high-precision dispensing technique using a nickel electroformed tube with an inner diameter accuracy of 5 μm or less. When dispensing variation of 100 nL was evaluated by using a photometric method, the most stable coefficients of variation (CV) were observed for a tube thickness of 50 μm with hydrophobic treatment, where the average CV value was 1.3%, i.e., 1.3 nL. Furthermore, the glucose concentration of 100and 200-nL animal-based control serum was colorimetrically measured using enzymatic reactions without drying and mixing reagents. The CV value was approximately 6.36% at 100 nL and 3.23% at 200 nL, suggesting that several biochemical panels can be precisely measured even from less than one drop of blood. This positive-displacement dispenser ensures zero contamination and almost-zero dead volume, thus it would be useful for multi-panel clinical blood testing.
1 January 1994 in Journal of the Society of Naval Architects of Japan
5 June 2020 in BUNSEKI KAGAKU
The precise dispensing of droplets is a crucial step for acquiring reliable diagnostic results. When a source sample volume is limited, the need for precise dispensing of submicroliter and nanoliter quantities is especially important. In this study, we developed a positive-displacement high-precision dispensing technique using a nickel electroformed tube with an inner diameter accuracy of ±0.7 μm. The dispensing variation of 0.1 μL was evaluated using a photometric method. To reduce liquid retention on the edge of the electroformed tube, the outside surfaces of the tube were hydrophobically treated with self-assembled monolayers on a gold surface. Regarding the results, the most stable coefficients of variation (CV) was 0.70 %, i.e. 0.70 nL. Furthermore, the glucose and cholesterol concentrations in 0.2 μL of animal-based control serum were colorimetrically measured with enzymatic reactions. The CV value of the analysis was approximately 2.38 % and 1.45 %, respectively, suggesting that several biochemical panels can be precisely measured even from one drop of whole blood (∼10 μL). The present positive-displacement dispenser ensures zero contamination and an almost-zero dead volume, and therefore would be useful for multi-panel clinical blood diagnosis.
6 February 2024 in Analytical Sciences
One of the challenges in liquid biopsy for early cancer detection is ascribed to the fact that mutation DNA often represents an extremely small ratio of less than 1% compared to wild-type genes in blood. However, in conventional fragment analysis with capillary electrophoresis (CE), the detectable allele frequency could be about 5%. In this work, we developed an original reagent-based fragment analysis with single base extension (SBE) reactions for cancer-associated mutation assay using a commercially available CE device, and investigated on a possibility of improvement of limit of detection (LOD) for genetic mutation. First, after adjustment of reagent conditions for the SBE reactions, the linear relationship between gene template concentration and fluorescence intensity was obtained from 1 to 100 fmol of target genes. Next, from the results of an experiment to detect mutation EGFR L858R at abundance ratios of mutant type to wild type (100-fmol template) of 0, 1, 5, and 10%, it was shown that the target gene can be detected with LOD of 0.33%. This high sensitivity was realized in part by separating fluorescently labeled substrates into an individual tube for an each-colored SBE reaction. Moreover, mutations EGFR L858R and KRAS G12V were simultaneously detected at sensitivities equivalent to LODs of 0.57 and 0.47%, respectively. These results indicate that < 1% of mutations in multiplex gene mutations can be simultaneously detected, and that possibility suggests that the developed method can be used in clinical practice for detecting cancers. Graphical abstract