The Iseult project is a French-German initiative focused on very high magnetic-field molecular imaging. The project includes a Whole Body 11.7 T MRI magnet installed at Neurospin, a neuroscience research center operating at CEA Saclay since November 2006. After 7 years of fabrication at Belfort by GE Power (Ex Alstom), the Iseult magnet was delivered to CEA in June 2017, its connection with the cryoplant and all the ancillary equipment was completed in October 2018. After 4 months of cooldown and another 4 months of tests, the Iseult magnet reached its nominal field of 11.72T without any quench for the first time, on July 18th. This paper deals with the magnet connection at Neurospin with the cryoplant and with the electrical and control systems. Finally, the paper will present the magnet commissioning data, from the cooling phase to the step-by-step energization up to the nominal current.
7 December 2016 in IEEE Transactions on Applied Superconductivity
Screening currents are a major concern when designing high-temperature superconducting magnets as they can have a drastic impact on the generated field level, homogeneity and temporal stability. Thus, the following article will present results from an experimental and numerical study of the screening current induced effects in a small-sized ReBCO coil. On the experimental side, two small single pancakes have been wound from 4 mm-wide Kapton-insulated ReBCO tape provided by manufacturer SuperOx and high-sensitivity Hall probes were mounted on the coils to monitor their generated field. The coils have then been tested at liquid nitrogen temperature, both at the remanent state and with transport current to measure the time decay of the Screening Current-Induced Field (SCIF). The experimental systems have also been modeled for magnetodynamic simulations using the free and open-source software GetDP and Gmsh. A 2D axisymmetrical FEM model of the coils has been built, accounting for the detailed layer structure of the windings. An H-ϕ formulation was used, using an E(J) powerlaw for the superconductor behavior and cohomology to enforce current constraints. First results obtained with this model are presented, showing its capability to simulate screening currents in coils of several tens of turns. Yet, its accuracy and computation time will need to be further improved. The presented results are a first milestone in our investigation for efficient and inexpensive methods to simulate screening currents in ReBCO HTS coils.
27 February 2018 in IEEE Transactions on Applied Superconductivity
The EuCARD High Temperature Superconductor (HTS) insert is a dipole magnet generating a self-field of 5,4 T and designed to operate at 18T within the FRESCA2 test facility; it has just been successfully tested in stand-alone configuration up to 4,5T. To operate in such a large field, its winding is made of a 12mm HTS REBCO insulated conductor; each conductor is composed of four tapes in parallel to achieve a large current of 2,8kA. The drawbacks of using parallel HTS tapes are numerous: firstly, they are very sensitive to orthogonal field inducing screening currents loops within the tapes. Secondly, the use of tapes in parallel imposes to transpose the conductor to avoid current loops between tapes, induced from the parallel field. The screening currents in return generate a magnetic field (Screening Current Induced Field), opposed to the main one and consequently lowering it and degrading the homogeneity. We have developed a finite difference code in order to simulate the induced currents within a conductor made of parallel tapes; we have calculated the SCIF and showed that the order of magnitude is non negligible compared to the main field. These computations have been benchmarked against measurement of the magnetic field performed during the stand-alone configuration tests.
The ability to measure nanoradian polarization rotations, , in the photon shot noise limit is investigated for partially crossed polarizers (PCP), a static Sagnac interferometer, and an optical bridge, each of which can in principle be used in this limit with near equivalent figures-of-merit (FOM). In practice a bridge to PCP/Sagnac source noise rejection ratio of enables the bridge to operate in the photon shot noise limit even at high light intensities. The superior performance of the bridge is illustrated via the measurement of a 3 nrad rotation arising from an axial magnetic field of 0.9 nT applied to a terbium gallium garnet. While the Sagnac is functionally equivalent to the PCP in terms of the FOM, unlike the PCP it is able to discriminate between rotations with different time (T) and parity (P) symmetries. The Sagnac geometry implemented here is similar to that used elsewhere to detect non-reciprocal ( ) rotations like those due to the Faraday effect. Using a Jones’ matrix approach, novel Sagnac geometries uniquely sensitive to non-reciprocal (e.g. magneto-electric or magneto-chiral) rotations, as well as to reciprocal rotations (e.g. due to linear birefringence, TP, or to chirality, ) are proposed.
22 April 2020 in IEEE Transactions on Applied Superconductivity
One of the frontier of particle physics beyond the Standard Model is the research of axion-like particles, to explain the absence of CP violation in the strong interaction and to provide dark matter candidates. In the MADMAX (MAgnetized Disk and Mirror AXion) experiment, the principle of axions detection relies on the predicted emission of an electric field, picked up using dielectric disks. The electric field intensity is proportional to the square of the local magnetic field, thus the MADMAX experiment would be set up in a 9 T NbTi dipole magnet, 6.9 m in length with a bore diameter of 1.35 m. The dipole produces a Figure of Merit over the surface of the disks of 100 T $^2$ m $^2$ along 2 meters, enough to detect axions with masses in the range of 100 μeV. This paper reports the 2D and 3D conceptual magnetic design of the MADMAX dipole. Starting from the experimental principles, it introduces the design parameters, constraints, and the methodology employed, aiming at minimizing the magnet cost minimizing the cost of the conductor. Then, the 2D and 3D designs are described, focusing in particular on the cross-section resulting from the 2D optimization and the heads optimization in 3D with and without iron, made by coupling a dedicated analytical approach to genetic algorithms.
15 September 2023 in IEEE Transactions on Applied Superconductivity
One of the challenges in the research of axion-like particles and ultimately in the exploration of the physics beyond the Standard Model is the high magnetic field required in large volume detectors. For the MADMAX (MAgnetized Disk and Mirror AXion) experiment, a 9 T NbTi block dipole magnet, 5.9 m in length with a bore diameter of 1.35 m, is required to detect axions with masses in the range of 100 μeV. Such large dimensions and demanding performances led to unconventional solutions for the magnet design. In this paper, the updated magnetic and mechanical design are reported. Starting from the updated physics requirements, the paper introduces the modifications adopted respect to the conceptual magnetic design and the impact of using cables-in-conduits. The magnetic and mechanical designs are described hereafter, showing the latest results in terms of optimization of the magnetic field peak, conductor cost, mechanical constraints and overall mass reduction.