Masters Candidate, Department of Civil and Environmental Engineering, University of Auckland, Private Bag 92019, Auckland Mail Centre, Auckland 1142, NZ
Auto-generated profile, based on publicly available information
Kelly A. Collins
Masters Candidate, Department of Civil and Environmental Engineering, University of Auckland, Private Bag 92019, Auckland Mail Centre, Auckland 1142, NZ
A permeable pavement parking lot in eastern North Carolina consisting of four types of permeable pavement and standard asphalt was monitored from June 2006 to July 2007 for hydrologic differences in pavement surface runoff volumes, total outflow volumes, peak flow rates, and time to peak. The four permeable sections were pervious concrete (PC), two types of permeable interlocking concrete pavement (PICP) with small-sized aggregate in the joints and having 12.9% (PICP1) and 8.5% (PICP2) open surface area, and concrete grid pavers (CGP) filled with sand. The site was located in poorly drained soils, and all permeable sections were underlain by a crushed stone base layer with a perforated underdrain. All permeable pavements significantly reduced surface runoff volumes and peak flow rates from those of asphalt (p<0.01) . Of the permeable pavements, CGP generated the greatest surface runoff volumes (p<0.01) . The PICP1 and CGP cells generated significantly lower total outflow volumes than all other sections ev...
A 1 year-old parking lot in eastern North Carolina consisting of four types of side-by-side permeable pavement and standard asphalt was monitored from January 2007 to July 2007 for water quality differences among pavement types. The four permeable sections were pervious concrete (PC), two different types of permeable interlocking concrete pavement (PICP) with small-sized aggregate in the joints and having 12.9% (PICP1) and 8.5% (PICP2) open surface area, and concrete grid pavers (CGP) filled with sand. The site was located in poorly drained soils, and all permeable sections were underlain by a crushed stone base with a perforated pipe underdrain. Composite, flow-weighted samples of atmospheric deposition and asphalt runoff were compared to those of permeable pavement subsurface drainage for pH, TN, NO2,3 –N , TKN, NH4 –N , and ON concentrations and loads. All pavements buffered acidic rainfall pH ( p<0.01 ) . The pH of permeable pavement subsurface drainage was higher than that of asphalt runoff ( p<0.01 ...
In 2008, the Center for Watershed Protection and the Chesapeake Stormwater Network developed the Runoff Reduction Method. The method was developed as part of a project to research and update best management practice (BMP) performance and, in particular, ascertain the ability of various BMPs to reduce post-development runoff volumes. The method focuses on the capability of conventional and innovative stormwater management practices (e.g., permeable pavement, green roofs, rainwater harvesting, bioretention, downspout disconnection, etc.) to reduce runoff, as well as remove pollutants, and incorporates built-in incentives for environmental site design, such as forest and open space preservation. Because of the high runoff reduction capabilities of various site design and innovative stormwater practices, implementing these innovative practices at a site reduces the overall number and size of structural BMPs required. This approach helps put innovative stormwater management practices on a level playing field with conventional stormwater management practices, such as wet and dry ponds. Currently, various state programs are in the process of using or adopting the Runoff Reduction Method as part of regulatory and non-regulatory programs. The Virginia Department of Conservation and Recreation (DCR) is integrating the Runoff Reduction Method into proposed stormwater management regulations and an updated stormwater management handbook. The Georgia Department of Natural Resources is modifying the method for a new Coastal Stormwater Management Manual Supplement. The State of Delaware is using the concept of runoff reduction in proposed statewide regulations. With the incorporation of the Runoff Reduction Method into these programs, communities are poised for the wide-spread implementation of low impact development and innovative stormwater management practices on development sites.
This current paper outlines the investigation procedures used to calibrate and verify a new hydrologic model on five permeable pavement structures in two different climates: Birkdale, New Zealand and North Carolina, USA. A beta version computer modelling package designed by the United States (US) Environmental Protection Agency (EPA), the Storm Water Management Model for Low Impact Design (SWMM5-LID(beta)), was used for the procedure. The calibrated model for the Birkdale site demonstrated accurate prediction of the system's response for both individual storms and continuous simulation (long-term). The model accurately predicts the peak flow response of the system for the highly frequent events (> 30% exceedance probability) with the measured and modelled flow frequency curves matching over this range. Volume control prediction is less accurate as the model over predicts retention for events greater than 10% exceedance by an average 4.7 mm. The calibrated model for the four North Carolina pavements (except for CGP) demonstrated accurate prediction for storms between 10 mm and 30 mm. The sand fill of the CGP provided additional storage which reduced peak underdrain outflow and volume. Modelling of this relationship requires significant modification of the fixed parameters in the model, which was not attempted. Simulated outflow hydrographs for storms 30 mm again had very similar shapes to the measured hydrographs but could not predict peak flows. Two parameters governed the response of the permeable pavement model: the drain coefficient and the drain exponent. A drain exponent of 3 is used in all of the models. A higher drain exponent increases the accuracy of the model but the corresponding drain coefficient becomes smaller and smaller. A calibrated drain coefficient of 0.000006 is used for the Birkdale site, and for the sites in North Carolina (PICP1, PICP2, CGP and PC) 0.00024, 0.001175, 0.00013 and 0.000725 respectively, were determined.
In 2006, the Connecticut Department of Environmental Protection issued an impervious cover Total Maximum Daily Load (TMDL) for the Eagleville Brook Watershed, located on the University of Connecticut (UConn) campus and the adjacent Town of Mansfield, CT. The TMDL, approved by the Environmental Protection Agency in February 2007, represents the first of its kind in the nation. While traditional TMDLs are typically target a specific pollutant, this one addresses the impacts of urban development directly by using impervious cover as the TMDL's metric. This approach was chosen because the Brook's biological impairment could not be attributed to any one pollutant. Since 5% of 303(d) listed waters in the nation are listed for "cause unknown — impaired biota," this project could set a national precedent for using impervious cover in a regulatory framework for implementing low-impact development (LID) practices at the watershed-scale. The project objective was to reduce the amount of effective IC in the watershed by either removing IC directly or by treating impervious cover using low impact development techniques. The project team conducted a stormwater retrofit inventory within the watershed, and identified 99 opportunities to treat or disconnect impervious cover on the UConn campus. Although IC is the "yardstick" to measure progress in this TMDL, the ultimate success will be the restoration of the biological communities in the Brook by improving the stream's habitat and water quality.