Wiebke Jahr

Wiebke Jahr

Auto-generated profile, based on publicly available information

Wiebke Jahr

Institute of Science and Technology Austria, Klosterneuburg, Austria

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 March 2021 in Nature Methods
Verified
Journal Article
Closed access
PDF file
HPHenry Pinkard
Henry Pinkard
NSNico Stuurman
Nico Stuurman
IIIvan E. Ivanov
Ivan E. Ivanov
NANicholas M. Anthony
Nicholas M. Anthony
WOWei Ouyang
Wei Ouyang
LWLaura Waller
Laura Waller

2 September 2015 in Nature Communications
Verified
Journal Article
Open access
PDF file
WJWiebke Jahr
Wiebke Jahr
BSBenjamin Schmid
Benjamin Schmid
CSChristopher Schmied
Christopher Schmied
FFFlorian O. Fahrbach
Florian O. Fahrbach
JHJan Huisken
Jan Huisken
To study the development and interactions of cells and tissues, multiple fluorescent markers need to be imaged efficiently in a single living organism. Instead of acquiring individual colours sequentially with filters, we created a platform based on line-scanning light sheet microscopy to record the entire spectrum for each pixel in a three-dimensional volume. We evaluated data sets with varying spectral sampling and determined the optimal channel width to be around 5 nm. With the help of these data sets, we show that our setup outperforms filter-based approaches with regard to image quality and discrimination of fluorophores. By spectral unmixing we resolved overlapping fluorophores with up to nanometre resolution and removed autofluorescence in zebrafish and fruit fly embryos.

25 August 2022 in Nature Methods
Verified
Journal Article
Open access
PDF file
JHJohannes Hohlbein
Johannes Hohlbein
BDBenedict Diederich
Benedict Diederich
BMBarbora Marsikova
Barbora Marsikova
Emmanuel G. ReynaudEmmanuel G. Reynaud
Emmanuel G. Reynaud
SHSéamus Holden
Séamus Holden
KPKirti Prakash
Kirti Prakash
Light microscopy enables researchers to observe cellular mechanisms with high spatial and temporal resolution. However, the increasing complexity of current imaging technologies, coupled with financial constraints of potential users, hampers the general accessibility and potential reach of cutting-edge microscopy. Open microscopy can address this issue by making well-designed and well-documented hardware and software solutions openly available to a broad audience. In this Comment, we provide a definition of open microscopy and present recent projects in the field. We discuss current and future challenges of open microscopy and their implications for funders, policymakers, researchers and scientists. We believe that open microscopy requires a holistic approach. Sample preparation, designing and building of hardware components, writing software, data acquisition and data interpretation must go hand in hand to enable interdisciplinary and reproducible science to the benefit of society.

1 January 2010 in Review of Scientific Instruments
Verified
Journal Article
Closed access
KZK. Zeil
K. Zeil
SKS. D. Kraft
S. D. Kraft
AJA. Jochmann
A. Jochmann
FKF. Kroll
F. Kroll
WJW. Jahr
W. Jahr
GPG. Pretzler
G. Pretzler
The characterization of the absolute number of electrons generated by laser wakefield acceleration often relies on absolutely calibrated FUJI imaging plates (IP), although their validity in the regime of extreme peak currents is untested. Here, we present an extensive study on the dependence of the sensitivity of BAS-SR and BAS-MS IP to picosecond electron bunches of varying charge of up to 60 pC, performed at the electron accelerator ELBE, making use of about three orders of magnitude of higher peak intensity than in prior studies. We demonstrate that the response of the IPs shows no saturation effect and that the BAS-SR IP sensitivity of 0.0081 photostimulated luminescence per electron number confirms surprisingly well data from previous works. However, the use of the identical readout system and handling procedures turned out to be crucial and, if unnoticed, may be an important error source.


10 July 2023 in Nature Methods
Verified
Journal Article
Open access
PDF file
PVPhilipp Velicky
Philipp Velicky
EMEder Miguel
Eder Miguel
JMJulia M. Michalska
Julia M. Michalska
JLJulia Lyudchik
Julia Lyudchik
DWDonglai Wei
Donglai Wei
JDJohann G. Danzl
Johann G. Danzl
Three-dimensional (3D) reconstruction of living brain tissue down to an individual synapse level would create opportunities for decoding the dynamics and structure–function relationships of the brain’s complex and dense information processing network; however, this has been hindered by insufficient 3D resolution, inadequate signal-to-noise ratio and prohibitive light burden in optical imaging, whereas electron microscopy is inherently static. Here we solved these challenges by developing an integrated optical/machine-learning technology, LIONESS (live information-optimized nanoscopy enabling saturated segmentation). This leverages optical modifications to stimulated emission depletion microscopy in comprehensively, extracellularly labeled tissue and previous information on sample structure via machine learning to simultaneously achieve isotropic super-resolution, high signal-to-noise ratio and compatibility with living tissue. This allows dense deep-learning-based instance segmentation and 3D reconstruction at a synapse level, incorporating molecular, activity and morphodynamic information. LIONESS opens up avenues for studying the dynamic functional (nano-)architecture of living brain tissue.