1 June 2015 in Biomaterials
The electrode material is a key element in the design of long-term neural implants and neuroprostheses. To date, the ideal electrode material offering high longevity, biocompatibility, low-noise recording and high stimulation capabilities remains to be found. We show that 3D-nanostructured boron doped diamond (BDD), an innovative material consisting in a chemically stable material with a high aspect ratio structure obtained by encapsulation of a carbon nanotube template within two BDD nanolayers, allows neural cell attachment, survival and neurite extension. Further, we developed arrays of 20-μm-diameter 3D-nanostructured BDD microelectrodes for neural interfacing. These microelectrodes exhibited low impedances and low intrinsic recording noise levels. In particular, they allowed the detection of low amplitude (10-20 μV) local-field potentials, single units and multiunit bursts neural activity in both acute whole embryonic hindbrain-spinal cord preparations and long-term hippocampal cell cultures. Also, cyclic voltammetry measurements showed a wide potential window of about 3 V and a charge storage capacity of 10 mC.cm(-2), showing high potentiality of this material for neural stimulation. These results demonstrate the attractiveness of 3D-nanostructured BDD as a novel material for neural interfacing, with potential applications for the design of biocompatible neural implants for the exploration and rehabilitation of the nervous system.
13 November 2017 in Advanced Functional Materials
Brain–computer interfaces and neural prostheses based on the detection of electrocorticography (ECoG) signals are rapidly growing fields of research. Several technologies are currently competing to be the first to reach the market; however, none of them fulfill yet all the requirements of the ideal interface with neurons. Thanks to its biocompatibility, low dimensionality, mechanical flexibility, and electronic properties, graphene is one of the most promising material candidates for neural interfacing. After discussing the operation of graphene solution‐gated field‐effect transistors (SGFET) and characterizing their performance in saline solution, it is reported here that this technology is suitable for μ‐ECoG recordings through studies of spontaneous slow‐wave activity, sensory‐evoked responses on the visual and auditory cortices, and synchronous activity in a rat model of epilepsy. An in‐depth comparison of the signal‐to‐noise ratio of graphene SGFETs with that of platinum black electrodes confirms that graphene SGFET technology is approaching the performance of state‐of‐the art neural technologies.
27 August 2009 in Langmuir
2 August 2011 in Soft Matter
Interfacing nanowires and living cells is highly interesting in various fields including biomedical implants, biosensors or drug delivery. Vertically aligned silicon nanowire (SiNW) arrays prepared by the stain etching technique were investigated in this study. Chemical modification with octadecyltrichlorosilane (OTS) led to the formation of superhydrophobic SiNW surface with a contact angle around 160°. A micropatterned superhydrophilic/superhydrophobic SiNW surface was fabricated using standard optical lithography techniques. Here we report on Chinese Hamster Ovary K1 (CHO) cell culture on patterned superhydrophilic/superhydrophobic silicon nanowire surfaces. It was found that the cells adhered selectively to the superhydrophilic regions while cell adhesion was almost completely suppressed on the superhydrophobic surface. Transmission electron microscopy analysis showed that the cell cytoplasmic projections penetrate the hydrophilic silicon nanowires layer and coat the nanowires, leading to an intimate surface contact and thus a strong adhesion. On the superhydrophobic surface, the cell cytoplasmic projections remained on the top of wires. The nonfouling of the superhydrophobic SiNW substrate was attributed to a stable Cassie–Baxter state, limiting the contact with the culture medium. Another interesting finding from this study is the corrosion of the superhydrophilic SiNW surface in phosphate-buffered saline (PBS) solution.
1 January 2013 in Biomaterials
We have established long-term cultures of postnatal retinal cells on arrays of gallium phosphide nanowires of different geometries. Rod and cone photoreceptors, ganglion cells and bipolar cells survived on the substrates for at least 18 days in vitro. Glial cells were also observed, but these did not overgrow the neuronal population. On nanowires, neurons extended numerous long and branched neurites that expressed the synaptic vesicle marker synaptophysin. The longest nanowires (4 μm long) allowed a greater attachment and neurite elongation and our analysis suggests that the length of the nanowire per se and/or the adsorption of biomolecules on the nanowires may have been important factors regulating the observed cell behavior. The study thus shows that CNS neurons are amenable to gallium phosphide nanowires, probably as they create conditions that more closely resemble those encountered in the in vivo environment. These findings suggest that gallium phosphide nanowires may be considered as a material of interest when improving existing or designing the next generation of implantable devices. The features of gallium phosphide nanowires can be precisely controlled, making them suitable for this purpose.
21 March 2011 in Lab on a Chip
We present for the first time an electrowetting on dielectric (EWOD) microfluidic system coupled to a surface-assisted laser desorption–ionization (SALDI) silicon nanowire-based interface for mass spectrometry (MS) analysis of small biomolecules. Here, the transfer of analytes has been achieved on specific locations on the SALDI interface followed by their subsequent mass spectrometry analysis without the use of an organic matrix. To achieve this purpose, a device comprising a digital microfluidic system and a patterned superhydrophobic/superhydrophilic silicon nanowire interface was developed. The digital microfluidic system serves for the displacement of the droplets containing analytes, via an electrowetting actuation, inside the superhydrophilic patterns. The nanostructured silicon interface acts as an inorganic target for matrix-free laser desorption–ionization mass spectrometry analysis of the dried analytes. The proposed device can be easily used to realize several basic operations of a Lab-on-Chip such as analyte displacement and rinsing prior to MS analysis. We have demonstrated that the analysis of low molecular weight compounds (700 m/z) can be achieved with a very high sensitivity (down to 10 fmol μL−1).