Austin Cronin

Austin Cronin

Auto-generated profile, based on publicly available information

Austin Cronin

Dermatology Service, Department of Veterans Affairs Tennessee Valley Healthcare System Nashville Tennessee USA

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 March 2022 in British Journal of Haematology
Verified
Journal Article
Closed access
AMAndrew McNeil
Andrew McNeil
KPKelsey Parks
Kelsey Parks
XLXiaoqi Liu
Xiaoqi Liu
ISInga Saknite
Inga Saknite
FCFuyao Chen
Fuyao Chen
ETEric R. Tkaczyk
Eric R. Tkaczyk

24 June 2021 in JID Innovations
Verified
Journal Article
Open access
LBLaura X. Baker
Laura X. Baker
FCFuyao Chen
Fuyao Chen
ACAustin Cronin
Austin Cronin
HCHeidi Chen
Heidi Chen
AVArved Vain
Arved Vain
ETEric R. Tkaczyk
Eric R. Tkaczyk
Skin biomechanical parameters (dynamic stiffness, frequency, relaxation time, creep, and decrement) measured using a myotonometer (MyotonPRO) could inform the management of sclerotic disease. To determine which biomechanical parameter(s) can accurately differentiate patients with sclerotic chronic graft-versus-host disease from post–hematopoietic cell transplant controls, 15 patients with sclerotic chronic graft-versus-host disease and 11 post–hematopoietic cell transplant controls were measured with the myotonometer on 18 anatomic sites. Logistic regression and two machine learning algorithms (least absolute shrinkage and selection operator regression and random forest) were developed to classify subjects. In univariable analysis, frequency had the highest overfit-corrected area under the curve (0.91). Backward stepwise selection and random forest machine learning identified frequency and relaxation time as the optimal parameters for differentiating patients with sclerotic chronic graft-versus-host disease from post–hematopoietic cell transplant controls. Least absolute shrinkage and selection operator regression selected the combination of frequency and relaxation time (overfit-corrected area under the curve = 0.87). Discriminatory ability was maintained when only the sites accessible while the patient is supine (12 sites) were used. We report the distribution of values for these highly discriminative biomechanical parameters, which could inform the assessment of disease severity in future quantitative biomechanical studies of sclerotic chronic graft-versus-host disease.

2 March 2023 in Journal of Biophotonics
Verified
Journal Article
Closed access
ACAustin Cronin
Austin Cronin
ETEric R. Tkaczyk
Eric R. Tkaczyk
IHIftak Hussain
Iftak Hussain
ABAudrey Bowden
Audrey Bowden
ISInga Saknite
Inga Saknite