Richard M. Crooks

Richard M. Crooks

Auto-generated profile, based on publicly available information

Richard M. Crooks

Department of Chemistry, Texas A&M University, P. O. Box 30012, College Station, USA

Research Focus & Metrics

Academic Career Length

28Years (1999-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 December 2000 in Accounts of Chemical Research
Verified
Journal Article
Closed access
RCRichard M. Crooks
Richard M. Crooks
MZMingqi Zhao
Mingqi Zhao
LSLi Sun
Li Sun
VCVictor Chechik
Victor Chechik
LYLee K. Yeung
Lee K. Yeung

10 May 2004 in The Analyst
Verified
Journal Article
Closed access
PDF file
RHRonald R. Henriquez
Ronald R. Henriquez
TITakashi Ito
Takashi Ito
LSLi Sun
Li Sun
RCRichard M. Crooks
Richard M. Crooks
This review discusses recent advances in the science and technology of Coulter counting. The Coulter counting principle has been used to determine the size, concentration, and in favorable cases the surface charge, of nanometer-scale colloidal particles, viruses, DNA and other polymers, and metal ions. A resurgence of interest in the field of Coulter counting is occurring because of the advent of new technologies that permit fabrication of membranes containing single, robust, and chemically well-defined channels having smaller and more uniform sizes than could be prepared in the past. These channels are prepared from biological materials, such as self-assembling membrane proteins, and from synthetic materials such as polymers, carbon nanotubes, and silicon-based inorganic materials. In addition to particle characterization, there have been a few recent examples of using Coulter counters to study chemical processes, such as the dehybridization of DNA.

15 August 2005 in Lab on a Chip
Verified
Journal Article
Closed access
PDF file
RDRahul Dhopeshwarkar
Rahul Dhopeshwarkar
LSLi Sun
Li Sun
RCRichard M. Crooks
Richard M. Crooks
A simple and efficient approach for concentration of charged molecules in microfluidic devices is described. The functional component of the system is a hydrogel microplug photopolymerized within the main channel of a microfluidic device. When an appropriately biased voltage is applied across the hydrogel, charged analyte molecules move from the source well toward the hydrogel. Transport of the analyte through the hydrogel is slow compared to its velocity in the microfluidic channel, however, and therefore it concentrates at the hydrogel/solution interface. For an uncharged hydrogel, a bias of 100 V leads to a ∼500-fold enrichment of the DNA concentration within 150 s, while the same conditions result in an enrichment of only 50-fold for fluorescein. Somewhat lower enrichment factors are observed when a negatively charged hydrogel is used. A qualitative model is proposed to account for the observed behavior.

1 June 1999 in Angewandte Chemie International Edition
Verified
Journal Article
Closed access
PDF file
PGPradyut Ghosh
Pradyut Ghosh
MAMary Lee Amirpour
Mary Lee Amirpour
WLWilliam M. Lackowski
William M. Lackowski
MPMichael V. Pishko
Michael V. Pishko
RCRichard M. Crooks
Richard M. Crooks

29 May 2003 in Chemical Communications
Verified
Journal Article
Closed access
PDF file
TITakashi Ito
Takashi Ito
LSLi Sun
Li Sun
RCRichard M. Crooks
Richard M. Crooks
DNA transport through a single multiwall carbon nanotube (MWNT) channel was directly observed via fluorescence microscopy.

1 February 1999 in Angewandte Chemie
Verified
Journal Article
Closed access
PDF file
MZMingqi Zhao
Mingqi Zhao
RCRichard M. Crooks
Richard M. Crooks