Andrew Barnes

Andrew Barnes

Auto-generated profile, based on publicly available information

Andrew Barnes

Academy for Sport and Physical Activity, Sheffield Hallam University, Sheffield, UK

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 June 2020 in Sports
Verified
Journal Article
Open access
PDF file
Steve ThompsonSteve Thompson
Steve Thompson
DRDavid Rogerson
David Rogerson
HDHarry F. Dorrell
Harry F. Dorrell
ARAlan Ruddock
Alan Ruddock
ABAndrew Barnes
Andrew Barnes
This study investigated the inter-day and intra-device reliability, and criterion validity of six devices for measuring barbell velocity in the free-weight back squat and power clean. In total, 10 competitive weightlifters completed an initial one repetition maximum (1RM) assessment followed by three load-velocity profiles (40–100% 1RM) in both exercises on four separate occasions. Mean and peak velocity was measured simultaneously on each device and compared to 3D motion capture for all repetitions. Reliability was assessed via coefficient of variation (CV) and typical error (TE). Least products regression (LPR) (R2) and limits of agreement (LOA) assessed the validity of the devices. The Gymaware was the most reliable for both exercises (CV < 10%; TE < 0.11 m·s−1, except 100% 1RM (mean velocity) and 90‒100% 1RM (peak velocity)), with MyLift and PUSH following a similar trend. Poorer reliability was observed for Beast Sensor and Bar Sensei (CV = 5.1–119.9%; TE = 0.08–0.48 m·s−1). The Gymaware was the most valid device, with small systematic bias and no proportional or fixed bias evident across both exercises (R2 > 0.42–0.99 LOA = −0.03–0.03 m·s−1). Comparable validity data was observed for MyLift in the back squat. Both PUSH devices produced some fixed and proportional bias, with Beast Sensor and Bar Sensei being the least valid devices across both exercises (R2 > 0.00–0.96, LOA = −0.36–0.46 m·s−1). Linear position transducers and smartphone applications could be used to obtain velocity-based data, with inertial measurement units demonstrating poorer reliability and validity.

11 December 2019 in Sports Medicine
Verified
Journal Article
Open access
PDF file
Steve ThompsonSteve Thompson
Steve Thompson
DRDavid Rogerson
David Rogerson
ARAlan Ruddock
Alan Ruddock
ABAndrew Barnes
Andrew Barnes
Background: Optimal prescription of resistance exercise load (kg) is essential for the development of maximal strength. Two methods are commonly used in practice with no clear consensus on the most effective approach for the improvement of maximal strength.Objective: The primary aim of this review was to compare the effectiveness of percentage 1RM (% 1RM) and repetition maximum targets (RM) as load prescription methods for the development of maximal strength.Methods: Electronic database searches of MEDLINE, SPORTDiscus, Scopus, and CINAHL Complete were conducted in accordance with PRISMA guidelines. Studies were eligible for inclusion if a direct measure of maximal strength was used, a non-training control group was a comparator, the training intervention was > 4 weeks in duration and was replicable, and participants were defined as healthy and between the ages of 18–40. Methodological quality of the studies was evaluated using a modified Downs and Black checklist. Percentage change (%) and 95% confidence intervals (CI) for all strength-based training groups were calculated. Statistical significance (p < 0.05) was reported from each study.Results: Twenty-two studies comprising a total of 761 participants (585 males and 176 females) were found to meet the inclusion criteria. 12 studies were returned for % 1RM, with 10 for RM. All studies showed statistically significant improvements in maximal strength in the training groups (31.3 ± 21.9%; 95% CI 33.1–29.5%). The mean quality rating for all studies was 17.7 ± 2.3. Four studies achieved a good methodological rating, with the remainder classified as moderate.Conclusions: Both % 1RM and RM are effective tools for improving maximal strength. % 1RM appears to be a better prescriptive method than RM potentially due to a more sophisticated management of residual fatigue. However, large heterogeneity was present within this data. Lower body and multi-joint exercises appear to be more appropriate for developing maximal strength. Greater consensus is required in defining optimal training prescriptions, physiological adaptations, and training status.

4 July 2017 in International Journal of Performance Analysis in Sport
Verified
Journal Article
Closed access
AHAngus Hughes
Angus Hughes
ABAndrew Barnes
Andrew Barnes
SCSarah M. Churchill
Sarah M. Churchill
JSJoseph A Stone
Joseph A Stone
This study aimed to identify performance indicators that discriminate winning and losing in elite men’s and women’s Rugby Union during the latest World Cup competitions. The knockout stages of the men’s 2015 Rugby World Cup (n = 8) and women’s 2014 Rugby World Cup (n = 8) were compared. Findings suggest that in the men’s game, winning teams kicked a greater percentage of possession in the opposition 22–50 m with a view to gaining territory and pressuring the opposition (winners = 16%, losers = 7%). In the women’s game successful teams adopted a more possession-driven attacking approach in this area of the pitch. Successful women’s teams appear more willing to attack with ball in hand following a kick receipt and adopt a more expansive game through attacking with wider carries in the outside channels. The percentage of lineouts won on the opposition ball was found to be an important performance indicator that discriminates winners and losers, regardless of sex (winners = 18%, losers = 11%). Findings suggest successful men’s and women’s teams adopt different tactical approaches to knockout competitions, this knowledge should be used as a basis for coaches to develop tactical approaches and training methods which are sex dependent.

3 April 2013 in International Journal of Performance Analysis in Sport
Verified
Journal Article
Closed access
LBLuke Bishop
Luke Bishop
ABAndrew Barnes
Andrew Barnes
The identification of performance indicators critical for success will allow the development of effective tactical approaches suited to the modern game. The aim of this study was to investigate the performance indicators that discriminate winning and losing teams in the knockout stages of the 2011 Rugby World Cup. Winning and losing teams from the eight knockout matches of the 2011 Rugby World Cup were compared based on several performance indicators previously associated with match success. A Wilcoxon test revealed statistical differences between only two performance indicators with winning teams conceding a higher percentage of their penalties between 50m and the opposition 22m than losing teams (P = 0.036) and winning teams kicking the ball out of hand more than losing teams (P = 0.040). Trends were noted in other indicators which supported the notion that winning teams adopted a more territory based strategy rather than a possession based approach to the game. Discipline in reducing the penalty count when defending in your own half was also found to be key in minimising potential scoring opportunities for the attacking team. At the 2011 Rugby World cup, a territory based approach appeared to be the most effective strategy for game success.

22 June 2021 in Sports
Verified
Journal Article
Open access
PDF file
Steve ThompsonSteve Thompson
Steve Thompson
DRDavid Rogerson
David Rogerson
ARAlan Ruddock
Alan Ruddock
LGLeon Greig
Leon Greig
HDHarry F. Dorrell
Harry F. Dorrell
ABAndrew Barnes
Andrew Barnes
The study aim was to compare different predictive models in one repetition maximum (1RM) estimation from load-velocity profile (LVP) data. Fourteen strength-trained men underwent initial 1RMs in the free-weight back squat, followed by two LVPs, over three sessions. Profiles were constructed via a combined method (jump squat (0 load, 30–60% 1RM) + back squat (70–100% 1RM)) or back squat only (0 load, 30–100% 1RM) in 10% increments. Quadratic and linear regression modeling was applied to the data to estimate 80% 1RM (kg) using 80% 1RM mean velocity identified in LVP one as the reference point, with load (kg), then extrapolated to predict 1RM. The 1RM prediction was based on LVP two data and analyzed via analysis of variance, effect size (g/ηp2), Pearson correlation coefficients (r), paired t-tests, standard error of the estimate (SEE), and limits of agreement (LOA). p < 0.05. All models reported systematic bias < 10 kg, r > 0.97, and SEE < 5 kg, however, all linear models were significantly different from measured 1RM (p = 0.015 <0.001). Significant differences were observed between quadratic and linear models for combined (p < 0.001; ηp2 = 0.90) and back squat (p = 0.004, ηp2 = 0.35) methods. Significant differences were observed between exercises when applying linear modeling (p < 0.001, ηp2 = 0.67–0.80), but not quadratic (p = 0.632–0.929, ηp2 = 0.001–0.18). Quadratic modeling employing the combined method rendered the greatest predictive validity. Practitioners should therefore utilize this method when looking to predict daily 1RMs as a means of load autoregulation.

15 May 2018 in Sports Engineering
Verified
Journal Article
Open access
PDF file
LBLeona Brayne
Leona Brayne
ABAndrew Barnes
Andrew Barnes
BHBen Heller
Ben Heller
JWJonathan Wheat
Jonathan Wheat
Real-time monitoring and feedback of tibial acceleration using wireless skin mounted sensors may reduce the risk of tibial stress fractures in runners. The purpose of this study was to assess the agreement between a wireless accelerometer and a gold standard reference accelerometer, both skin mounted, in measuring peak axial tibial acceleration when treadmill running at a range of speeds. A research grade accelerometer was mounted to a wireless accelerometer and attached to the tibia. Peak positive tibial accelerations of 13 participants were compared at 2.5, 3.5 and 4.5 m s− 1. Intraclass correlation coefficients demonstrated good agreement, with limits of agreement showing accuracy to within 1.2–1.65 g. The wireless accelerometer has scope to be used as a tool to measure peak tibial accelerations during running for the purpose of real-time feedback in gait training systems.