Ryan S. Alcantara

Ryan S. Alcantara

Auto-generated profile, based on publicly available information

Ryan S. Alcantara

Department of Integrative Physiology, University of Colorado Boulder, Boulder, CO, USA

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 January 2022 in PeerJ
Verified
Journal Article
Open access
PDF file
RARyan S. Alcantara
Ryan S. Alcantara
WEW. Brent Edwards
W. Brent Edwards
GMGuillaume Y. Millet
Guillaume Y. Millet
AGAlena M. Grabowski
Alena M. Grabowski
Background: Ground reaction forces (GRFs) are important for understanding human movement, but their measurement is generally limited to a laboratory environment. Previous studies have used neural networks to predict GRF waveforms during running from wearable device data, but these predictions are limited to the stance phase of level-ground running. A method of predicting the normal (perpendicular to running surface) GRF waveform using wearable devices across a range of running speeds and slopes could allow researchers and clinicians to predict kinetic and kinematic variables outside the laboratory environment. Purpose: We sought to develop a recurrent neural network capable of predicting continuous normal (perpendicular to surface) GRFs across a range of running speeds and slopes from accelerometer data. Methods: Nineteen subjects ran on a force-measuring treadmill at five slopes (0°, ±5°, ±10°) and three speeds (2.5, 3.33, 4.17 m/s) per slope with sacral- and shoe-mounted accelerometers. We then trained a recurrent neural network to predict normal GRF waveforms frame-by-frame. The predicted versus measured GRF waveforms had an average ± SD RMSE of 0.16 ± 0.04 BW and relative RMSE of 6.4 ± 1.5% across all conditions and subjects. Results: The recurrent neural network predicted continuous normal GRF waveforms across a range of running speeds and slopes with greater accuracy than neural networks implemented in previous studies. This approach may facilitate predictions of biomechanical variables outside the laboratory in near real-time and improves the accuracy of quantifying and monitoring external forces experienced by the body when running.

12 April 2021 in PeerJ
Verified
Journal Article
Open access
PDF file
RARyan S. Alcantara
Ryan S. Alcantara
EDEvan M. Day
Evan M. Day
MHMichael E. Hahn
Michael E. Hahn
AGAlena M. Grabowski
Alena M. Grabowski
Background: Stress fractures are injuries caused by repetitive loading during activities such as running. The application of advanced analytical methods such as machine learning to data from multiple wearable sensors has allowed for predictions of biomechanical variables associated with running-related injuries like stress fractures. However, it is unclear if data from a single wearable sensor can accurately estimate variables that characterize external loading during running such as peak vertical ground reaction force (vGRF), vertical impulse, and ground contact time. Predicting these biomechanical variables with a single wearable sensor could allow researchers, clinicians, and coaches to longitudinally monitor biomechanical running-related injury risk factors without expensive force-measuring equipment. Purpose: We quantified the accuracy of applying quantile regression forest (QRF) and linear regression (LR) models to sacral-mounted accelerometer data to predict peak vGRF, vertical impulse, and ground contact time across a range of running speeds. Methods: Thirty-seven collegiate cross country runners (24 females, 13 males) ran on a force-measuring treadmill at 3.8–5.4 m/s while wearing an accelerometer clipped posteriorly to the waistband of their running shorts. We cross-validated QRF and LR models by training them on acceleration data, running speed, step frequency, and body mass as predictor variables. Trained models were then used to predict peak vGRF, vertical impulse, and contact time. We compared predicted values to those calculated from a force-measuring treadmill on a subset of data (n = 9) withheld during model training. We quantified prediction accuracy by calculating the root mean square error (RMSE) and mean absolute percentage error (MAPE). Results: The QRF model predicted peak vGRF with a RMSE of 0.150 body weights (BW) and MAPE of 4.27 ± 2.85%, predicted vertical impulse with a RMSE of 0.004 BW*s and MAPE of 0.80 ± 0.91%, and predicted contact time with a RMSE of 0.011 s and MAPE of 4.68 ± 3.00%. The LR model predicted peak vGRF with a RMSE of 0.139 BW and MAPE of 4.04 ± 2.57%, predicted vertical impulse with a RMSE of 0.002 BW*s and MAPE of 0.50 ± 0.42%, and predicted contact time with a RMSE of 0.008 s and MAPE of 3.50 ± 2.27%. There were no statistically significant differences between QRF and LR model prediction MAPE for peak vGRF (p = 0.549) or vertical impulse (p = 0.073), but the LR model’s MAPE for contact time was significantly lower than the QRF model’s MAPE (p = 0.0497). Conclusions: Our findings indicate that the QRF and LR models can accurately predict peak vGRF, vertical impulse, and contact time (MAPE < 5%) from a single sacral-mounted accelerometer across a range of running speeds. These findings may be beneficial for researchers, clinicians, or coaches seeking to monitor running-related injury risk factors without force-measuring equipment.

1 June 2018 in Gait & Posture
Verified
Journal Article
Closed access
RARyan S. Alcantara
Ryan S. Alcantara
MTMatthieu B. Trudeau
Matthieu B. Trudeau
EREric S. Rohr
Eric S. Rohr

3 July 2017 in PLOS ONE
Verified
Journal Article
Open access
PDF file
RARyan S. Alcantara
Ryan S. Alcantara
CWCara M. Wall-Scheffler
Cara M. Wall-Scheffler
Running with a stroller provides an opportunity for parents to exercise near their child and counteract health declines experienced during early parenthood. Understanding biomechanical and physiological changes that occur when stroller running is needed to evaluate its health impact, yet the effects of stroller running have not been clearly presented. Here, three commonly used stroller pushing methods were investigated to detect potential changes in energetic cost and lower-limb kinematics. Sixteen individuals (M/F: 10/6) ran at self-selected speeds for 800m under three stroller conditions (2-Hands, 1-Hand, and Push/Chase) and an independent running control. A significant decrease in speed (p = 0.001) and stride length (p<0.001) was observed between the control and stroller conditions, however no significant change in energetic cost (p = 0.080) or heart rate (p = 0.393) was observed. Additionally, pushing method had a significant effect on speed (p = 0.001) and stride length (p<0.001). These findings suggest that pushing technique influences stroller running speed and kinematics. These findings suggest specific fitness effects may be achieved through the implementation of different pushing methods.

6 December 2019 in Journal of Open Source Software
Verified
Journal Article
Open access
PDF file
RARyan Alcantara
Ryan Alcantara

28 April 2020 in European Journal of Applied Physiology
Verified
Journal Article
Closed access
PDF file
RARyan S. Alcantara
Ryan S. Alcantara
OBOwen N. Beck
Owen N. Beck
AGAlena M. Grabowski
Alena M. Grabowski