Ryoto Iwai

Ryoto Iwai

Auto-generated profile, based on publicly available information

Ryoto Iwai

Swiss Federal Institute of Technology in Zurich (ETH)

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 March 2025 in The European Physical Journal D
Verified
Journal Article
Open access
PDF file
PSPatrick Strasser
Patrick Strasser
MAMitsushi Abe
Mitsushi Abe
KAKanta Asai
Kanta Asai
SFSeiso Fukumura
Seiso Fukumura
MFMahiro Fushihara
Mahiro Fushihara
(C(MuSEUM Collaboration)
(MuSEUM Collaboration)
At the J-PARC Muon Science Facility (MUSE), the MuSEUM collaboration is now performing new precision measurements of the ground state hyperfine structure (HFS) of both muonium and muonic helium atoms. High-precision measurements of the muonium ground-state HFS are recognized as one of the most sensitive tools for testing bound-state quantum electrodynamics theory to precisely probe the standard model and determine fundamental constants of the positive muon magnetic moment and mass. The same technique can also be employed to measure muonic helium HFS, obtain the negative muon magnetic moment and mass, and test and improve the theory of the three-body atomic system. Measurements at zero magnetic field have already yielded more accurate results than previous experiments for both muonium and muonic helium atoms. High-field measurements are now ready to start collecting data using the world’s most intense pulsed muon beam at the MUSE H-line. We aim to improve the precision of previous measurements ten times for muonium and a hundred times or more for muonic helium. We review all the key developments for these new measurements, focusing on the high-field experiment, and report the latest results and prospects.

21 December 2023 in Physical Review Letters
Verified
Journal Article
Closed access
PDF file
PSPatrick Strasser
Patrick Strasser
SFSeiso Fukumura
Seiso Fukumura
RIR. Iwai
R. Iwai
SKSohtaro Kanda
Sohtaro Kanda
SKShiori Kawamura
Shiori Kawamura
MCMuSEUM Collaboration
MuSEUM Collaboration
Muonic helium atom hyperfine structure (HFS) measurements are a sensitive tool to test the three-body atomic system and bound-state quantum electrodynamics theory, and determine fundamental constants of the negative muon magnetic moment and mass. The world’s most intense pulsed negative muon beam at the Muon Science Facility of the Japan Proton Accelerator Research Complex allows improvement of previous measurements and testing further CPT invariance by comparing the magnetic moments and masses of positive and negative muons (second-generation leptons). We report new ground-state HFS measurements of muonic helium-4 atoms at a near-zero magnetic field, performed for the first time using a small admixture of CH4 as an electron donor to form neutral muonic helium atoms efficiently. Our analysis gives Δν=4464.980(20)  MHz (4.5 ppm), which is more precise than both previous measurements at weak and high fields. The muonium ground-state HFS was also measured under the same conditions to investigate the isotopic effect on the frequency shift due to the gas density dependence in He with CH4 admixture and compared with previous studies. Muonium and muonic helium can be regarded as light and heavy hydrogen isotopes with an isotopic mass ratio of 36. No isotopic effect was observed within the current experimental precision.

12 June 2024 in Physics
Verified
Journal Article
Open access
PDF file
SFSeiso Fukumura
Seiso Fukumura
PSPatrick Strasser
Patrick Strasser
MFMahiro Fushihara
Mahiro Fushihara
YGYu Goto
Yu Goto
TITakashi Ino
Takashi Ino
HTHiroyuki A. Torii
Hiroyuki A. Torii
The mass mμ− of the negative muon is one of the parameters of the elementary particle Standard Model and it allows us to verify the CPT (charge–parity–time) symmetry theorem by comparing mμ− value with the mass mμ+ of the positive muon. However, the experimental determination precision of mμ− is 3.1ppm, which is an order of magnitude lower than the determination precision of mμ+ at 120ppb. The authors aim to determine mμ− and the magnetic moment μμ− with a precision of O(10ppb) through spectroscopy of the hyperfine structure (HFS) of muonic helium-4 atom (4Heμ−e−) under high magnetic fields. He4μ−e− is an exotic atom where one of the two electrons of the He4 atom is replaced by a negative muon. To achieve the goal, it is necessary to determine the HFS of He4μ−e− with a precision of O(1ppb). This paper describes the determination procedure of the HFS of He4μ−e− in weak magnetic fields reported recently, and the work towards achieving the goal of higher precision measurement.

11 May 2024 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Verified
Journal Article
Closed access
RIR. Iwai
R. Iwai
SFS. Fukumura
S. Fukumura
MFM. Fushihara
M. Fushihara
YGY. Goto
Y. Goto
SKSohtaro Kanda
Sohtaro Kanda
HTH.A. Torii
H.A. Torii

4 December 2023
Verified
Conference Paper
Open access
PDF file
RIRyoto Iwai
Ryoto Iwai
MAMitsushi Abe
Mitsushi Abe
SFSeiso Fukumura
Seiso Fukumura
MFMahiro Fushihara
Mahiro Fushihara
YGYu Goto
Yu Goto
HTHiroyuki A Torii
Hiroyuki A Torii
In muon physics at low energies (keV-MeV), spectroscopy of muonium atoms takes a significant role in fundamental physics at precision and intensity frontiers. Efforts are invested nowadays in testing theoretical calculations of the Standard Model with a precision down to $\approx1$ ppb. New measurements for two energy intervals of the muonium, the 1s hyperfine structure and the 1s-2s interval, are designed utilizing new generations of muon sources and new experimental techniques for microwave and laser spectroscopy. These ongoing experiments will also determine the muon mass and magnetic moment with unprecedented precisions. This paper first reviews the current experimental activities on precision spectroscopy of the muonium atoms. The latter part focuses on new measurements of the 1s hyperfine splitting by the MuSEUM collaboration at J-PARC. Future measurement plans using a rectangular shaped microwave cavity are also described.

20 October 2025 in SciPost Physics Core
Verified
Journal Article
Open access
PDF file
AAAldo Antognini
Aldo Antognini
NANicholas J. Ayres
Nicholas J. Ayres
IBIvana Belosevic
Ivana Belosevic
VBVira Bondar
Vira Bondar
AEAndreas Eggenberger
Andreas Eggenberger
TYTaylor Yan
Taylor Yan
We present the first demonstration of simultaneous phase space compression in two spatial dimensions of a positive muon beam, the first stage of the novel high-brightness muon beam under development by the muCool collaboration at the Paul Scherrer Institute. The keV-energy, sub-mm size beam would enable a factor 10^5 10 5 improvement in brightness for precision \mu μ SR, and atomic and particle physics measurements with positive muons. This compression is achieved within a cryogenic helium gas target with a strong density gradient, placed in a homogeneous magnetic field, under the influence of a complex electric field. In the next phase, the muon beam will be extracted into vacuum.