Mariusz Krajewski

Mariusz Krajewski

Auto-generated profile, based on publicly available information

Mariusz Krajewski

Uniwersytet Zielonogorski, Inst Metrol Elekt & Informatyki, Ul Prof Z Szafrana 2, PL-65156 Zielona Gora, Poland

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 August 2018 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
Wiesław MiczulskiWiesław Miczulski
Wiesław Miczulski
MKMariusz Krajewski
Mariusz Krajewski
SSSergiusz Sienkowski
Sergiusz Sienkowski
In this paper, a concept of an intelligent temperature transducer (ITT) featuring a new autocalibration procedure cooperating with a platinum resistance temperature detector (RTD) is presented. This procedure is based on the application of resistors representing the standards of the measured temperature. The effect of this procedure is the minimization of linearity errors of the ITT processing characteristic, including the RTD, and the minimization of the ITT offset and gain errors. In the adopted ITT solution, the compensation of the RTD wires resistance is applied. The simulation and experimental research results, which confirm the high effectiveness of this procedure, are presented. The uncertainty of temperature measurement by means of the Monte Carlo method is evaluated and experimental research results, confirming the possibility of measuring temperature within a range of 0 °C-200 °C with a 0.03 °C uncertainty, are presented.

24 January 2018 in Metrologia
Verified
Journal Article
Closed access
PDF file
MKMariusz Krajewski
Mariusz Krajewski
This paper presents a way of constructing an uncertainty budget for root mean square (RMS) voltage measurement with an integrating sampling voltmeter and a discreet Fourier transform (DFT) algorithm. The construction of an uncertainty budget based on the Monte Carlo method is proposed. Such a budget makes it possible to analyse metrological properties of RMS measurement, especially in cases difficult to realize by the classical method of uncertainty determination. An application of the proposed research method is illustrated by voltage RMS measurement with a high-accuracy HP3458A sampling voltmeter. Selected simulation results have been experimentally verified.

30 November 2024 in Sensors
Verified
Journal Article
Open access
PDF file
Wiesław MiczulskiWiesław Miczulski
Wiesław Miczulski
MKMariusz Krajewski
Mariusz Krajewski
SSSergiusz Sienkowski
Sergiusz Sienkowski
EKElżbieta Kawecka
Elżbieta Kawecka
APAndrzej Perec
Andrzej Perec
The article presents an intelligent temperature transducer (ITT), which can work with a two-wire or a three-wire platinum resistance temperature detector (RTD). The ITT design allowed for compensation of the RTD’s lead wire resistance. The ITT used the author’s auto-calibration procedure, which minimized linearity errors of the ITT and RTD processing characteristics, ITT offset and gain errors, and errors resulting from changes in the ITT operating conditions concerning the nominal conditions. The presented results of a simulation and experimental studies confirmed the high effectiveness of this procedure. The determined uncertainty of temperature measurement using the Monte Carlo method and the obtained experimental results confirmed the possibility of measuring temperatures in the range of 0–200 °C with an expanded uncertainty of 0.02 °C at a 99% confidence level.

1 January 2018 in PRZEGLĄD ELEKTROTECHNICZNY
Verified
Journal Article
Closed access
MKMariusz Krajewski
Mariusz Krajewski
The article presents the results of the simulation properties of selected digital algorithms to estimate the frequency, in the operating conditions of instruments for accurate measurements of sinusoidal voltage. A developed algorithm based on a phase shift measurement with a use of DFT (Discrete Fourier Transform) and four algorithms known from literature, three with spectral interpolation and a total least squares (TLS), were applied. The research results indicate that the developed algorithm is characterized by the best properties.

28 March 2018 in Metrology and Measurement Systems
Verified
Journal Article
Closed access
PDF file
SSSergiusz Sienkowski
Sergiusz Sienkowski
MKMariusz Krajewski
Mariusz Krajewski

1 January 2022 in PRZEGLĄD ELEKTROTECHNICZNY
Verified
Journal Article
Closed access
SSSergiusz Sienkowski
Sergiusz Sienkowski
MKMariusz Krajewski
Mariusz Krajewski
The article evaluates the accuracy of the estimating results of the mean value of a sinusoidal voltage. For this purpose, a mean value estimator calculated from voltage samples has been used. The bias, the variance and the mean squared error of an estimator have been determined.