Benjamin I. Binder-Macleod

Benjamin I. Binder-Macleod

Auto-generated profile, based on publicly available information

Benjamin I. Binder-Macleod

School of Biomedical Engineering, Science, and Health Systems, Drexel University, Philadelphia, PA, USA; Department of Physical Therapy and Rehabilitation Sciences, Drexel University, Philadelphia, PA, USA

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 October 2022 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
DMDaniel C. McFarland
Daniel C. McFarland
BBBenjamin I. Binder-Markey
Benjamin I. Binder-Markey
JNJennifer A. Nichols
Jennifer A. Nichols
SWSarah J. Wohlman
Sarah J. Wohlman
MBMarije de Bruin
Marije de Bruin
WMWendy M. Murray
Wendy M. Murray
Objective: The purpose of this work was to develop an open-source musculoskeletal model of the hand and wrist and to evaluate its performance during simulations of functional tasks. Methods: The current model was developed by adapting and expanding upon existing models. An optimal control theory framework that combines forward-dynamics simulations with a simulated-annealing optimization was used to simulate maximum grip and pinch force. Active and passive hand opening were simulated to evaluate coordinated kinematic hand movements. Results: The model's maximum grip force production matched experimental measures of grip force, force distribution amongst the digits, and displayed sensitivity to wrist flexion. Simulated lateral pinch strength replicated in vivo palmar pinch strength data. Additionally, predicted activations for 7 of 8 muscles fell within variability of EMG data during palmar pinch. The active and passive hand opening simulations predicted reasonable activations and demonstrated passive motion mimicking tenodesis, respectively. Conclusion: This work advances simulation capabilities of hand and wrist models and provides a foundation for future work to build upon. Significance: This is the first open-source musculoskeletal model of the hand and wrist to be implemented during both functional kinetic and kinematic tasks. We provide a novel simulation framework to predict maximal grip and pinch force which can be used to evaluate how potential surgical and rehabilitation interventions influence these functional outcomes while requiring minimal experimental data.

19 December 2023 in eLife
Verified
Journal Article
Open access
BCBryce Chung
Bryce Chung
MZMuneeb Zia
Muneeb Zia
KTKyle A Thomas
Kyle A Thomas
JMJonathan A Michaels
Jonathan A Michaels
AJAmanda Jacob
Amanda Jacob
SSSamuel J Sober
Samuel J Sober
Neurons coordinate their activity to produce an astonishing variety of motor behaviors. Our present understanding of motor control has grown rapidly thanks to new methods for recording and analyzing populations of many individual neurons over time. In contrast, current methods for recording the nervous system’s actual motor output – the activation of muscle fibers by motor neurons – typically cannot detect the individual electrical events produced by muscle fibers during natural behaviors and scale poorly across species and muscle groups. Here we present a novel class of electrode devices (‘Myomatrix arrays’) that record muscle activity at unprecedented resolution across muscles and behaviors. High-density, flexible electrode arrays allow for stable recordings from the muscle fibers activated by a single motor neuron, called a ‘motor unit,’ during natural behaviors in many species, including mice, rats, primates, songbirds, frogs, and insects. This technology therefore allows the nervous system’s motor output to be monitored in unprecedented detail during complex behaviors across species and muscle morphologies. We anticipate that this technology will allow rapid advances in understanding the neural control of behavior and identifying pathologies of the motor system.

17 April 2020 in Frontiers in Physiology
Verified
Journal Article
Open access
BBBenjamin I. Binder-Markey
Benjamin I. Binder-Markey
NBNicole M. Broda
Nicole M. Broda
Richard LieberRichard Lieber
Richard Lieber
The passive load bearing properties of muscle are poorly understood partly due to challenges in identifying the connective tissue structures that bear loads. Prior attempts to correlate passive mechanical properties with collagen content (often expressed as a mass ratio and used as a surrogate for connective tissue quantity within muscle) have not been successful. This is likely a result of not accounting for variability in intramuscular connective tissue throughout a muscle such that a single collagen content value likely does not adequately represent the connective tissue load bearing capacity of a muscle. Therefore, the purpose of this study was to determine how intramuscular connective tissue distribution throughout a muscle impacts measured collagen content. For this analysis, four mouse hindlimb muscles were chosen because of their varying actions and anatomy; rectus femoris, semimembranosus, tibialis anterior, and lateral gastrocnemius. Collagen content throughout each muscle was determined biochemically using an optimized hydroxyproline assay. Dense connective tissue distribution throughout each muscle’s length was quantified histologically. We found that collagen content varied widely within and between muscles, from 3.6 ±0.40 SEM μg/mg wet weight to 15.6 ±1.58 SEM μg/mg, which is dependent on both the specific location within a muscle and particular muscle studied. Both collagen content and connective tissue structures demonstrated stereotypically patterns with the highest quantity at the proximal and distal ends of the muscles. Additionally, using three independent approaches, (1) linear regression, (2) predictive modeling, and (3) nonlinear optimization, we found complementary and corroborating evidence suggesting a strongly correlated relationship between a muscle’s connective tissue distribution and collagen content. Specifically, we found that muscle collagen content is driven primarily by its dense connective tissue structures due to the extremely high collagen content of connective tissue (227.52 to 334.69 μg/mg) compared to muscle tissue (1.93 to 4.03 μg/mg). A consequence of these findings is that a single collagen content measurement does not accurately represent a muscle’s complex distribution of connective tissue. Future studies should account for collagen content variations and connective tissue anatomy to establish more accurate relationships between collagen content measurements and whole muscle passive mechanics.


1 October 2024 in Journal of Applied Physiology
Verified
Journal Article
Closed access
LPLomas S. Persad
Lomas S. Persad
ZWZheng Wang
Zheng Wang
PPPaula A. Pino
Paula A. Pino
BBBenjamin I. Binder-Markey
Benjamin I. Binder-Markey
KKKenton R. Kaufman
Kenton R. Kaufman
Richard LieberRichard Lieber
Richard Lieber
The intrinsic force production capability of human muscle can be expressed as “Specific Tension,” or, the maximum force generated per cross-sectional area of muscle fibers. This value can be used to determine, for example, whether muscle quality changes during exercise, atrophy, disease, or hypertrophy. A value of 22.5 N/cm2 for mammalian muscle has generally become accepted based on detailed studies of small mammals. Determining the specific tension of human muscle is much more challenging as almost all determinations are indirect. Calculation of human muscle specific tension requires an understanding of that muscle’s contribution to joint torque, its activation magnitude, tendon compliance, and joint moment arm. Determining any of these parameters is technically challenging in humans and thus, it is no surprise that human specific tension values reported vary from 2 to 73 N/cm2. In this systematic review, we screened 1,506 published papers and identified the 30 studies published between 1983 and 2023 that used appropriate methods and which reported 96 human specific tension values. We weighted each parameter based on whether it was directly measured, estimated, or calculated based on the literature, with decreasing weighting used, the more indirect the methods. Based on this exhaustive review of the relevant human literature, we suggest that the most accurate value that should be used for human muscle specific tension is 26.8 N/cm2.

1 September 2019 in The Journal of Hand Surgery
Verified
Journal Article
Closed access
BBBenjamin I. Binder-Markey
Benjamin I. Binder-Markey
JDJulius P.A. Dewald
Julius P.A. Dewald
WMWendy M. Murray
Wendy M. Murray