Xiaoxia Yan

Xiaoxia Yan

Auto-generated profile, based on publicly available information

Xiaoxia Yan

College of Sciences, Shanghai University, Shanghai 200444, China

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 August 2016 in Electrochimica Acta
Verified
Journal Article
Closed access
FTFen Tao
Fen Tao
XYXiao-Xia Yan
Xiao-Xia Yan
JLJun-Ji Liu
Jun-Ji Liu
HZHonglei Zhang
Honglei Zhang
LCLi Chen
Li Chen

1 November 2021 in Current Analytical Chemistry
Verified
Journal Article
Closed access
PDF file
KHKe Huan
Ke Huan
LTLi Tang
Li Tang
DDDongmei Deng
Dongmei Deng
HWHuan Wang
Huan Wang
SXSi Xiaojing
Si Xiaojing
Liqiang LuoLiqiang Luo
Liqiang Luo
Background: Hydrogen peroxide (H2O2) is a common reagent in the production and living, but excessive H2O2 may enhance the danger to the human body. Consequently, it is very important to develop economical, fast and accurate techniques for detecting H2O2. Methods: A simple two-step electrodeposition process was applied to synthesize Pd-Cu/Cu2O nanocomposite for non-enzymatic H2O2 sensor. Cu/Cu2O nanomaterial was firstly electrodeposited on FTO by potential oscillation technique, and then Pd nanoparticles were electrodeposited on Cu/Cu2O nanomaterial by cyclic voltammetry. The chemical structure, component, and morphology of the synthesized Pd-Cu/Cu2O nanocomposite were characterized by X-ray diffraction, scanning electron microscopy and X-ray photoelectron spectroscopy. The electrochemical properties of Pd-Cu/Cu2O nanocomposite were studied by cyclic voltammetry and amperometry. Results: Under optimal conditions, the as-fabricated sensor displayed a broad linear range (5-4000 μM) and low detection limit (1.8 μM) for the determination of H2O2. The proposed sensor showed good selectivity and reproducibility. Meanwhile, the proposed sensor has been successfully applied to detect H2O2 in milk. Conclusion: The Pd-Cu/Cu2O/FTO biosensor exhibits excellent electrochemical activity for H2O2 reduction, which has great potential application in the field of food safety.

26 October 2020 in Current Analytical Chemistry
Verified
Journal Article
Closed access
PDF file
LZLin Zhang
Lin Zhang
SXSi Xiaojing
Si Xiaojing
XYXiaoxia Yan
Xiaoxia Yan
HHHaibo He
Haibo He
DDDongmei Deng
Dongmei Deng
Liqiang LuoLiqiang Luo
Liqiang Luo
Background: Paracetamol is a common antipyretic and analgesic drug, but its excessive intake can accumulate toxic metabolites and cause kidney and liver damage, so it is critical to determine the content of paracetamol for clinical diagnosis and dose use. Methods: Au-reduced graphene oxide (Au-rGO) nanocomposite decorated with poly(L-cysteine) on carbon paste electrode was fabricated for the determination of paracetamol. Au-rGO was first coelectrodeposited on the carbon paste electrode surface. Afterwards, L-cysteine was electropolymerized to fabricate the Au-rGO/poly(L-cysteine) modified carbon paste electrode. Scanning electron microscope was used to characterize the morphology of Au-rGO and poly(L-cysteine)/Au-rGO. The electrochemical properties of the sensor were studied by cyclic voltammetry and differential pulse voltammetry. Results: After exploring the optimal conditions, the sensor showed a wide linear response for paracetamol detection in the range of 1-200 μM with a detection limit of 0.5 μM (S/N = 3). Conclusion: The fabricated sensor demonstrated good sensitivity with rapid detection capacity in real samples.