Total arch replacement using the frozen elephant trunk procedure is performed for true lumen expansion of the descending aorta in patients with type A acute aortic dissection. However, the remodelling effect of the frozen elephant trunk on the dissected descending aorta is unclear. We aimed to evaluate the effect of the frozen elephant trunk on postoperative descending aortic remodelling after surgery. Between December 2012 and January 2020, we retrospectively investigated 24 patients who underwent total arch replacement using the frozen elephant trunk for type A acute aortic dissection. Remodelling of the descending aorta was evaluated using computed tomography. The aortic remodelling effect, based on aortic true lumen ratio, was determined for (i) DeBakey type (type I versus type III retrograde); (ii) thoracic endovascular aneurysm repair reintervention status (reintervention versus no reintervention); and (iii) stent length of the frozen elephant trunk (60 vs 90 mm). Postoperative true lumen ratio significantly increased in the type I dissection group. The true lumen ratio in the no-reintervention group, which had many patients with the type I dissection, significantly increased after the frozen elephant trunk. Aortic remodelling due to the frozen elephant trunk can be expected after type I acute aortic dissections.
Spinal cord injury (SCI) following endovascular aortic repair (EVAR) for an abdominal aortic aneurysm (AAA) is a rare but serious complication. Case 1 presented with ruptured AAA and shock and underwent emergency EVAR. The patient developed incomplete paraplegia 2 days following EVAR. Case 2, diagnosed with impending rupture of AAA with extremely shaggy aorta, was treated with emergency EVAR. The patient was diagnosed with complete paraplegia soon after EVAR. Case 3 underwent elective EVAR and developed delayed paraplegia 2 weeks later. In EVAR, the etiology of SCI leading to paraplegia is often multifactorial. Surgeons must consider the possibility of SCI-induced paraplegia.
1 September 2021 in Journal of Vascular Surgery Cases, Innovations and Techniques
Isolated deep femoral artery aneurysms are rare and tend to be large at the time of diagnosis owing to their deep anatomic location. Deep femoral artery aneurysms are often complicated by rupture, with subsequent lower limb amputation. However, a large aneurysm can compress the surrounding deep femoral vein, leading to thrombosis. In the present report, we have described a rare surgical case of deep femoral artery aneurysm complicated by deep femoral vein thrombosis and pulmonary embolism. Preoperative inferior vena cava filter placement was effective for preventing perioperative worsening of the pulmonary embolism in this particular circumstance.