31 May 2017 in European Radiology
21 June 2019 in European Radiology
1 May 2013 in Physica Medica
24 September 2019 in Medical Physics
Purpose: Xtrim‐PET is a newly designed Silicon Photomultipliers (SiPMs)‐based prototype PET scanner dedicated for small laboratory animal imaging. We present the performance evaluation of the Xtrim‐PET scanner following NEMA NU‐4 2008 standards to help optimizing scanning protocols which can be achieved through standard and reliable system performance characterization.Methods: The performance assessment was conducted according to the National Electrical Manufacturers Association (NEMA) NU‐4 2008 standards in terms of spatial resolution, sensitivity, counting rate performance, scatter fraction and image quality. The in vivo imaging capability of the scanner is also showcased through scanning a normal mouse injected with 18F‐FDG. Furthermore, the performance characteristics of the developed scanner are compared with commercially available systems and current prototypes.Results: The volumetric spatial resolution at 5 mm radial offset from the central axis of the scanner is 6.81 µl, whereas a peak absolute sensitivity of 2.99% was achieved using a 250–650 keV energy window and a 10 ns timing window. The peak noise‐equivalent count rate (NECR) using a mouse‐like phantom is 113.18 kcps at 0.34 KBq/cc with 12.5% scatter fraction, whereas the NECR peaked at 82.76 kcps for an activity concentration level of 0.048 KBq/cc with a scatter fraction of 25.8% for rat‐like phantom. An excellent uniformity (3.8%) was obtained using NEMA image quality phantom. Recovery coefficients of 90%, 86%, 68%, 40% and 12% were calculated for rod diameters of 5, 4, 3, 2 and 1 mm, respectively. Spill‐over ratios for air‐filled and water‐filled chambers were 35% and 25% without applying any correction for attenuation and Compton scattering effects.Conclusion: Our findings revealed that beyond compactness, lightweight, easy installation and good energy resolution, the Xtrim‐PET prototype presents a reasonable performance making it suitable for preclinical molecular imaging‐based research.
11 April 2022 in Medical Physics
Objectives: This study is aimed at examining the synergistic impact of motion and acquisition/reconstruction parameters on18F‐FDG PET image radiomic features in non‐small cell lung cancer (NSCLC) patients, and investigating the robustness of features performance in differentiating NSCLC histopathology subtypes.Methods: An in‐house developed thoracic phantom incorporating lesions with different sizes was used with different reconstruction settings, including various reconstruction algorithms, number of subsets and iterations, full‐width at half‐maximum of post‐reconstruction smoothing filter and acquisition parameters, including injected activity and test–retest with and without motion simulation. To simulate motion, a special motor was manufactured to simulate respiratory motion based on a normal patient in two directions. The lesions were delineated semi‐automatically to extract 174 radiomic features. All radiomic features were categorized according to the coefficient of variation (COV) to select robust features. A cohort consisting of 40 NSCLC patients with adenocarcinoma (n= 20) and squamous cell carcinoma (n= 20) was retrospectively analyzed. Statistical analysis was performed to discriminate robust features in differentiating histopathology subtypes of NSCLC lesions.Results: Overall, 29% of radiomic features showed a COV ≤5% against motion. Forty‐five percent and 76% of the features showed a COV ≤ 5% against the test–retest with and without motion in large lesions, respectively. Thirty‐three percent and 45% of the features showed a COV ≤ 5% against different reconstruction parameters with and without motion, respectively. For NSCLC histopathological subtype differentiation, statistical analysis showed that 31 features were significant (p‐value < 0.05). Two out of the 31 significant features, namely, the joint entropy of GLCM (AUC = 0.71, COV = 0.019) and median absolute deviation of intensity histogram (AUC = 0.7, COV = 0.046), were robust against the motion (same reconstruction setting).Conclusions: Motion, acquisition, and reconstruction parameters significantly impact radiomic features, just as their synergies. Radiomic features with high predictive performance (statistically significant) in differentiating histopathological subtype of NSCLC may be eliminated due to non‐reproducibility.
1 March 2014 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
MFMohammad Hossein Farahani
Mohammad Hossein Farahani
+4