19 December 2022 in IEEE Transactions on Nanotechnology
Organic field-effect transistors (OFETs) have shown potential market in many low-power sensing applications. Toward that, the fabrication of sharp on/off OFET is essential. Herein, we present an attempt to fabricate OFET using polyaniline (PANI), in the form of PANI-nanofibers with a fiber diameter of 75 nm, as an active semiconductor layer. The polymethyl methacrylate (PMMA) is utilized as a gate dielectric with an aluminum bottom electrode. Top electrodes for both source and drain were fabricated of gold. The Primary, in-situ polymerization method is used in preparing the PANI as a semiconductor film. The morphological and optical properties of PANI nanofibers, as well as PMMA oxide thin-film, were investigated using SEM, FTIR, AFM, and UV-Vis. Spectrometer. The bandgap energy was observed to be 2.2 eV. Consequently, the I-V characteristics were studied for the device, showing a sharp sub-threshold response. An ultra-low threshold voltage of 0.17 V was recorded, promoting the fabricated devices for various sensing applications.
7 September 2023 in IEEE Transactions on Nanotechnology
cardiovascular diseases (CVDs) are the leading cause of death worldwide, killing over 17 million people yearly. A key biomarker for identifying myocardial infarction (MI) is the regulatory protein Cardiovascular Troponin I (cTnI), released into the blood following heart muscle injury. Significant efforts have been made in recent years to develop highly sensitive biosensors for the detection of cTnI. Field effect transistors (FETs) in general and organic FETs (OFETs) in specific have shown computability in detecting such cordial protein. In this study, we provide a complete attempt to fabricate and characterize polyaniline nanofiber (PANI-NFs) OFET for biosensing applications. The FTIR spectrum of PANI-NFs is examined before and after pAbs immobilization. To study the biosensor performance parameters, the biomarker drain current is investigated against the cTnI biomarker concentrations. The proposed OFET recorded high sensitivity of 484 nA.(g/mL) -1 , with a minimum detection limit (0.36 pg/mL) and power consumption varying from 7 μW to 11.4 μW. Finally, the biosensing repeatability was examined regarding variation in the P-FET device and the biasing conditions.
8 May 2025 in Applied Physics A
In this work, we reported the synthesis of a high-performance humidity sensor based on an indium oxide/zinc ferrite nanocomposite. The composite was prepared by hydrothermal technique, which resulted in a homogenous nanostructure. The structural and morphological characterizations were performed using XRD, FTIR, UV-Vis, SEM, EDX, TEM and BET techniques, confirming the formation of In₂O₃/ZnFe₂O₄ composite with well-defined particle sizes in the nanometer scale. The humidity sensing performance was evaluated in a wide range of relative humidity, from 11% up to 97%. The optimal testing frequency was determined to be 100 Hz. The results demonstrate that the prepared nanocomposite exhibits an excellent dynamic response characteristic. Also, the sensor demonstrated good repeatability in its response, showing stable performance across cycles. Furthermore, due to the porosity and high surface area, water vapor absorption and desorption occurred rapidly in the nanocomposite. These results indicate that In₂O₃/ZnFe₂O₄ nanocomposite is a promising candidate for humidity-sensing applications.
20 May 2025 in IEEE Sensors Journal
This study presents an experimentally driven numerical model for evaluating carbon/polyaniline (PANI)-based glucose monitoring sensors, focusing on innovative configurations using graphene-PANI and carbon nanotube (CNT)-PANI composites. We performed a thorough analysis of the morphological, electrophysical, and electrical properties of these materials, ultimately leading to the extraction of key electrical parameters for integration into a finite element model (FEM). This model simulates the entire sensor, enabling the estimation of critical performance metrics such as sensitivity, limit of detection (LOD), linearity, and power consumption. Our findings demonstrate that the CNT-PANI configuration significantly outperforms the laser induced graphene (LIG)-PANI electrode, achieving a figure of merit (FOM) of 0.99 compared to 0.62, thanks to its superior electrical conductivity and high surface area, which facilitates enhanced charge transfer and electrochemical reactions. The optimized sensor configurations reveal optimal parameters for LIG-PANI and CNT-PANI, underscoring the trade-offs between conductivity and overall sensor performance. Notably, the CNT-PANI composite exhibits the highest sensitivity of 2778 μA mM-1 cm-2 and the lowest LOD of 0.09 μM, making it a promising candidate for glucose detection in clinical applications. This work highlights the importance of power consumption in sensor design, with all configurations operating at 0.232 mW, and sets a new benchmark for future glucose monitoring technologies. Finally, the study illustrated a clinical investigation to verify the selectivity and sensitivity of PANI towards various molar concentrations of glucose.
2 June 2026 in IEEE Sensors Letters
This study presents an experimentally verified numerical model addressing time-dependent degradation and defect profiles in organic field-effect transistors (OFETs). We identified a significant research gap in understanding the interplay between defects and degradation mechanisms, which are crucial for enhancing OFET performance and reliability. Notably, our findings showed that the threshold voltage increased from 0.47 V to 1.70 V in bottom gate/top contact devices due to charge trap accumulation, while carrier mobility dropped from 5.1 cm²/V·s to 3.3 cm²/V·s. The model also captures the impact of environmental factors, with the simulation revealing a maximum RMSE deviation of 5.1%, underscoring threshold voltage as the most critical parameter affected by degradation. This comprehensive analysis provides valuable insights for future OFET optimization.