Montse Mesalles

Montse Mesalles

Auto-generated profile, based on publicly available information

Montse Mesalles

Affiliation Departament de Medicina i Cirurgia Animals, Facultat de Veterinària, Servei d’Hematologia Clínica Veterinària (SHCV), Universitat Autònoma de Barcelona (UAB), Cerdanyola del Vallès, Barcelona, Spain

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 April 2025 in Animals
Verified
Journal Article
Open access
PDF file
MMMontse Mesalles
Montse Mesalles
MUMeritxell Uroz
Meritxell Uroz
Irene BrandtsIrene Brandts
Irene Brandts
ESEmmanuel Serrano
Emmanuel Serrano
RCRafaela Cuenca
Rafaela Cuenca
MTMariana Teles
Mariana Teles
Hematological studies provide essential information about the health of animals, which is crucial for veterinary medicine, scientific research, and aquaculture. Automatic hematological analyzers are an alternative to manual methods, offering faster and more reliable results. The objective of this study was to validate the Sysmex XN-1000V automatic hematology analyzer for blood samples from rainbow trout (Oncorhynchus mykiss), examine the effects of two anticoagulants (K2EDTA and lithium heparin), and establish normal blood reference values for this fish species. Additionally, comparative studies were conducted between the Sysmex XN-1000V and manual methods (hemocytometer cell count and blood smear estimation), and reference intervals were established. Ninety-nine heparinized blood samples were analyzed for validation and sample stability tests. The results showed extremely good precision, with a coefficient of variation (CV) below 3% for RBCs, HGB, and HCT and less than 5% for non-RBC cells (leukocytes plus thrombocytes). However, heterophils (%) exhibited higher variability, with a CV of 15.08%. Linearity was excellent, and the carry-over was below 1% for all parameters. The sample stability test indicated that samples could be analyzed for up to 48 h when stored at 4 °C and up to 24 h at room temperature. Non-RBC cells were the first to degrade over time. The automated and manual methods demonstrated good correlation and agreement, validating the analyzer’s accuracy. The effects of two anticoagulants, K2EDTA and lithium heparin, on the blood samples were also studied. Heparin was the preferred anticoagulant for routine hematological analysis of rainbow trout blood with the Sysmex XN-1000V analyzer. In conclusion, the Sysmex XN-1000V enables complete hemogram analyses to be performed quickly and accurately, standardizing techniques, harmonizing results, and providing reliable reference intervals with O mykiss blood.

15 April 2024 in Veterinary Clinical Pathology
Verified
Journal Article
Open access
JMJavier Martínez-Caro
Javier Martínez-Caro
BABeatriz Agulla
Beatriz Agulla
CVClàudia Viñeta
Clàudia Viñeta
XRXavier Roura
Xavier Roura
MMMontse Mesalles
Montse Mesalles
JPJosep Pastor
Josep Pastor
A 10‐year‐old neutered male Maltese dog was presented for an investigation of lymphocytosis. The dog was up‐to‐date on vaccinations and deworming. Physical examination did not reveal any significant abnormalities. A complete blood cell count (CBC) showed mild leukocytosis with moderate lymphocytosis, basophilia, and moderate neutropenia, but no significant left shift or toxic change. Serum biochemistry and urinalysis were unremarkable. All performed tests for infectious agents common in this geographical region were negative. No significant abnormalities were found on abdominal ultrasound examination. Multiparametric flow cytometry of peripheral blood showed a CD8+ T‐cell lymphocytosis, and PCR for antigen receptor rearrangement revealed a clonal expansion of the T‐cell receptor gamma chain genes. A clinical diagnosis of chronic lymphocytic leukemia (CLL) was made, and follow‐up was recommended. On Day 48 post‐presentation, the CBC showed mild non‐regenerative anemia (NRA), moderate leucocytosis due to moderate to marked lymphocytosis, basophilia, and a marked increase in hyposegmented neutrophils with mild toxic change in the absence of neutrophilia or neutropenia. Treatment with chlorambucil and prednisolone was initiated. On Days 87 and 197 post‐presentation, the CBC showed mild NRA, with progressively decreasing numbers of hyposegmented neutrophils. The dog remained without clinical signs. Basophilia and probable pseudo‐Pelger–Huët anomaly were possibly secondary to CLL. To the authors' knowledge, this is the first report of these two hematologic conditions secondary to CLL in dogs. Recognition of a pseudo‐Pelger–Huët anomaly is clinically relevant to avoid misinterpretation as a marked left shift due to severe inflammation and prevent unnecessary urgent therapeutic actions.

6 July 2026 in PLOS ONE
Verified
Journal Article
Open access
PDF file
MMMontse Mesalles
Montse Mesalles
JPJosep Pastor
Josep Pastor
ESEmmanuel Serrano
Emmanuel Serrano
RCRafaela Cuenca
Rafaela Cuenca
LTLluís Tort
Lluís Tort
MTMariana Teles
Mariana Teles
Hematological analyses are widely used to assess the health and physiological status of animals, including fish. Automated hematology analyzers enable rapid and reproducible hematological measurements; however, their application in fish requires species-specific analytical validation due to the presence of nucleated blood cells. This study evaluated the analytical performance of the Sysmex XN-1000V hematology analyzer operated under avian settings (PLT-F channel), in juvenile gilthead seabream ( Sparus aurata ), one of the cornerstone species of Mediterranean marine aquaculture. Analytical validation included assessment of precision, linearity, carryover, and sample stability. Results were compared with manual reference methods (hemocytometer counts and blood smear-based estimates). In addition, the influence of two anticoagulants (lithium heparin and K₂EDTA) was examined, and the analyzer’s ability to detect lipopolysaccharide (LPS)-induced changes in non-erythroid cell population was evaluated. The analyzer showed good precision for most parameters (CV < 5%), although higher variability was observed for granulocyte percentage. Linearity was excellent (R 2 ≥ 0.98), and carryover remained below 1% for all variables. Sample stability was significantly better at 4 °C than at room temperature (25 °C), supporting refrigerated storage for up to 24 hours prior to analysis. Comparison with manual reference methods revealed strong correlations and agreement for red blood cell counts and hematocrit, whereas discrepancies were identified in non-erythroid cells differentials. Among anticoagulants, lithium heparin yielded more consistent and reliable results than K₂EDTA. Erythrocyte-related parameters showed the highest analytical reliability, whereas the leucocyte differentiation within the non-erythroid fraction required complementary microscopic evaluation, particularly when assessing LPS-induced inflammatory changes. Overall, the Sysmex XN-1000V demonstrated suitable analytical performance for routine hematological assessment in gilthead seabream when operated under avian settings. These findings support its application in aquaculture health monitoring programs, provided that appropriate anticoagulants are used, samples are promptly processed or refrigerated, and automated results are complemented by microscopic review when leukocyte counts are suspected.