10 March 2025 in PLOS ONE
The objective of this study is to explore innovative integration within the field of anatomy education by leveraging HoloLens 2 Augmented Reality Head-Mounted Display (AR HMD) technology and real-time cloud rendering. Initial 3D datasets, comprising extensive anatomical information for each bone, were obtained through the 3D scanning of a full-body cadaver of Korean male origin. Subsequently, these datasets underwent refinement processes aimed at enhancing visual fidelity and optimizing polygon counts, utilizing Blender software. Unity was employed for the development of the Metaverse platform, incorporating tailored 3D User Experience (UX) and User Interface (UI) components to facilitate interactive anatomy education via imported cadaver models. Integration with real-time remote rendering cloud servers, such as Azure, was implemented to augment the performance and rendering capabilities of the HoloLens 2 AR HMD. The extended reality (XR) content uses the Photon Cloud network for real-time data synchronization and HoloLens 2 voice functionality. The metaverse platform supports user interaction through room creation and joining, with various tools for bone manipulation, color differentiation, and surface output. Collaboration features enable sharing and synchronization of model states. The study highlights the importance of technological innovation in anatomy education for future medical professionals. The proposed content aims to address limitations of traditional methods and enhance learning experiences. Continued efforts in developing and improving such technologies are crucial to equip learners with essential skills for adaptation in the evolving healthcare landscape.
22 July 2022 in Radiation Physics and Chemistry
31 December 2024 in Progress in Medical Physics
Dong Hyeok Choi, Jin Sung Kim, So Hyun Ahn. Progress in Medical Physics 2024;35:106-15. https://doi.org/10.14316/pmp.2024.35.4.106
1 January 2021 in SSRN Electronic Journal
We need to monitor mechanical and dosimetric changes while performing periodic quality assurance (QA) to ensure that radiation therapy equipment maintains the same quality as when newly introduced. Annual QA should perform more QA items than other periodic QA, and it is recommended to apply the strictest tolerance even for the same items. The purpose of our study is to establish an efficient quality assurance (QA) procedure using a Stealth ChamberTM—a reference signal detector—as a field chamber. Among the annual QA items, relative dosimetry items such as monitor unit linearity, output constancy with dose rate, and output constancy with gantry angle were measured and compared with the results of the Farmer-type chamber. The results obtained using the Stealth ChamberTM for all items, except for the output constancy with gantry angle, were in good agreement with that obtained using the Farmer-type chamber within 1.0%. The output constancy item according to the gantry angle verified that the Stealth ChamberTM could reduce the effect of the setup error. Our study suggests that it will be possible to reduce the increasing QA burden in the future.
18 May 2022 in Frontiers in Veterinary Science
Purpose: The purpose of this study is to propose a technique for delivering accurate doses in an image-guided system by developing an experimental setup optimized for total lymphoid irradiation (TLI) in rat lung transplantation. Materials and Methods: In this study, a position-controlled shielding system was developed, and the dose was quantitatively evaluated using a 3D rat phantom and Gafchromic EBT3 film. In addition, we made our own image-guided system that allows the position of the rat and the shielding system to be confirmed during TLI. Results: As a result of using the position-controlled shielding system, it was found that the doses to the head and lungs were reduced by 93.1 and 87.4%, respectively, of the prescribed doses. In addition, it was shown that the position of the shielding system can be easily confirmed by using the image guidance system. Conclusion: A shielding apparatus that can control dose delivery according to the size of the rat can optimize the dose for TLI in rat lung transplantation.