Liu-Yang Chen

Liu-Yang Chen

Auto-generated profile, based on publicly available information

Liu-Yang Chen

MOE Key Laboratory of Fundamental Physical Quantities Measurement and Hubei Key Laboratory of Gravitation and Quantum Physics, PGMF, School of Physics, Huazhong University of Science and Technology 1 , Wuhan 430074

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2024 in Review of Scientific Instruments
Verified
Journal Article
Closed access
PDF file
YFYu-Jie Feng
Yu-Jie Feng
YJYuan-Ze Jiang
Yuan-Ze Jiang
GXGuoyao Xiao
Guoyao Xiao
LCLiu-Yang Chen
Liu-Yang Chen
BLBai-Fu Lu
Bai-Fu Lu
YLYu-Rong Liang
Yu-Rong Liang
High-precision phasemeters are a key technology in intersatellite laser interferometers used for detecting gravitational waves (GWs) in space. As the core of the readout system, the phasemeter must operate in the bandwidth of 5–25 MHz, and its resolution needs to reach the order of μrad/Hz at mHz. It presents significant challenges to electronic signal processing technology. To investigate the primary noise source in the low-frequency band, a mathematical model of thermal drift to phase noise was established, and a multi-point temperature sensing scheme for critical electronic components was proposed. In particular, we evaluated a phasemeter based on a commercial platform and assessed the thermal drift noise according to the proposed model. This study identifies and explains the effects of temperature linear drift and overcorrection in components, demonstrating that thermal drift noise is the main noise source for the phasemeter at frequencies from 0.1 to 1 mHz. In addition, the proposed scheme is universal in its applicability and may be implemented in any circuit for the evaluation of temperature effects on the components of interest.

5 November 2025 in Measurement
Verified
Journal Article
Closed access
YFYujie Feng
Yujie Feng
YJYuanze Jiang
Yuanze Jiang
LCLiuyang Chen
Liuyang Chen
HCHaifeng Chen
Haifeng Chen
YLYurong Liang
Yurong Liang

15 October 2026 in Measurement
Verified
Journal Article
Closed access
LCLiuyang Chen
Liuyang Chen
ZXZhilin Xu
Zhilin Xu
YJYuanze Jiang
Yuanze Jiang
YFYujie Feng
Yujie Feng
YLYurong Liang
Yurong Liang
ZZZebing Zhou
Zebing Zhou

18 May 2026 in SSRN Electronic Journal
Verified
Preprint
Open access
LCLiu-Yang Chen
Liu-Yang Chen
ZXZhi-Lin Xu
Zhi-Lin Xu
YJYuan-Ze Jiang
Yuan-Ze Jiang
YFYu-Jie Feng
Yu-Jie Feng
YLYu-Rong Liang
Yu-Rong Liang
ZZZebing Zhou
Zebing Zhou
A quadrant photodetector (QPD) with ultra-low electronic noise across a wide frequency response bandwidth is a critical component for achieving picometer-level sensitivity in inter-satellite laser interferometers used for space-borne gravitational wave detection. Although the electronic noise in state-of-the-art QPDs has reached a relatively optimal level, the absence of a precise theoretical model obscures potential noise sources, hindering further noise reduction. In this work, by incorporating the stray capacitance into the theoretical model and introducing an in-situ calibration method for the stray capacitance, we established and experimentally validated an advanced electronic noise model for the QPD. Applying this advanced noise model to optimize circuit design and chip packaging reduced the stray capacitance by 95%, resulting in a 15% decreasing in the electronic noise of QPD. These results confirm that the stray capacitance in the optoelectronic detection circuit is a significant factor in suppressing the electronic noise of QPDs. Our study clarifies the ultimate noise limitations and dominant factors of QPDs, providing practical design guidelines for their application in space-borne gravitational wave detection.