OBJECTIVE: To compare the efficacy of 2 intensified insulin regimens, continuous subcutaneous insulin infusion (CSII) and multiple daily injections (MDI), by using the short-acting insulin analog lispro in type 1 diabetic patients. RESEARCH DESIGN AND METHODS: A total of 41 C-peptide-negative type 1 diabetic patients (age 43.5+/-10.3 years; 21 men and 20 women, BMI 24.0+/-2.4 kg/m2, diabetes duration 20.0+/-11.3 years) on intensified insulin therapy (MDI with regular insulin or lispro, n = 9, CSII with regular insulin, n = 32) were included in an open-label randomized crossover study comparing two 4-month periods of intensified insulin therapy with lispro: one period by MDI and the other by CSII. Blood glucose (BG) was monitored before and after each of the 3 meals each day. RESULTS: The basal insulin regimen had to be optimized in 75% of the patients during the MDI period (mean number of NPH injections per day = 2.65). HbA1c values were lower when lispro was used in CSII than in MDI (7.89+/-0.77 vs. 8.24+/-0.77%, P<0.001). BG levels were lower with CSII (165+/-27 vs. 175+/-33 mg/dl, P<0.05). The SD of all the BG values (73+/-15 vs. 82+/-18 mg/dl, P<0.01) was lower with CSII. The frequency of hypoglycemic events, defined as BG levels <60 mg/dl, did not differ significantly between the 2 modalities (CSII 3.9+/-4.2 per 14 days vs. MDI 4.3+/-3.9 per 14 days). Mean insulin doses were significantly lower with CSII than with MDI (38.5+/-9.8 vs. 47.3+/-14.9 U/day. respectively, P< 0.0001). CONCLUSIONS: When used with external pumps versus MDI, lispro provides better glycemic control and stability with much lower doses of insulin and does not increase the frequency of hypoglycemic episodes.

23 May 2024 in Diabetologia
Verified
Journal Article
Open access
PDF file
GFGuy Fagherazzi
Guy Fagherazzi
GAGloria Aguayo
Gloria Aguayo
LZLu Zhang
Lu Zhang
HHHélène Hanaire
Hélène Hanaire
SPSylvie Picard
Sylvie Picard
JRJean-Pierre Riveline
Jean-Pierre Riveline
Aims/hypothesis: Our study aims to uncover glycaemic phenotype heterogeneity in type 1 diabetes. Methods: In the Study of the French-speaking Society of Type 1 Diabetes (SFDT1), we characterised glycaemic heterogeneity thanks to a set of complementary metrics: HbA1c, time in range (TIR), time below range (TBR), CV, Gold score and glycaemia risk index (GRI). Applying the Discriminative Dimensionality Reduction with Trees (DDRTree) algorithm, we created a phenotypic tree, i.e. a 2D visual mapping. We also carried out a clustering analysis for comparison. Results: We included 618 participants with type 1 diabetes (52.9% men, mean age 40.6 years [SD 14.1]). Our phenotypic tree identified seven glycaemic phenotypes. The 2D phenotypic tree comprised a main branch in the proximal region and glycaemic phenotypes in the distal areas. Dimension 1, the horizontal dimension, was positively associated with GRI (coefficient [95% CI]) (0.54 [0.52, 0.57]), HbA1c (0.39 [0.35, 0.42]), CV (0.24 [0.19, 0.28]) and TBR (0.11 [0.06, 0.15]), and negatively with TIR (−0.52 [−0.54, −0.49]). The vertical dimension was positively associated with TBR (0.41 [0.38, 0.44]), CV (0.40 [0.37, 0.43]), TIR (0.16 [0.12, 0.20]), Gold score (0.10 [0.06, 0.15]) and GRI (0.06 [0.02, 0.11]), and negatively with HbA1c (−0.21 [−0.25, −0.17]). Notably, socioeconomic factors, cardiovascular risk indicators, retinopathy and treatment strategy were significant determinants of glycaemic phenotype diversity. The phenotypic tree enabled more granularity than traditional clustering in revealing clinically relevant subgroups of people with type 1 diabetes. Conclusions/interpretation: Our study advances the current understanding of the complex glycaemic profile in people with type 1 diabetes and suggests that strategies based on isolated glycaemic metrics might not capture the complexity of the glycaemic phenotypes in real life. Relying on these phenotypes could improve patient stratification in type 1 diabetes care and personalise disease management. Graphical

30 July 2014 in Journal of Diabetes Science and Technology
Verified
Journal Article
Open access
SBSophie Borot
Sophie Borot
SFSylvia Franc
Sylvia Franc
JCJustine Cristante
Justine Cristante
APAlfred Penfornis
Alfred Penfornis
PBPierre-Yves Benhamou
Pierre-Yves Benhamou
OGon behalf of the Diabeloop Study Group
on behalf of the Diabeloop Study Group
Background: The JewelPUMP™ (JP) is a new patch pump based on a microelectromechanical system that operates without any plunger. The study aimed to evaluate the infusion accuracy of the JP in vitro and in vivo. Methods: For the in vitro studies, commercially available pumps meeting the ISO standard were compared to the JP: the MiniMed® Paradigm® 712 (MP), Accu-Chek® Combo (AC), OmniPod® (OP), Animas® Vibe™ (AN). Pump accuracy was measured over 24 hours using a continuous microweighing method, at 0.1 and 1 IU/h basal rates. The occlusion alarm threshold was measured after a catheter occlusion. The JP, filled with physiological serum, was then tested in 13 patients with type 1 diabetes simultaneously with their own pump for 2 days. The weight difference was used to calculate the infused insulin volume. Results: The JP showed reduced absolute median error rate in vitro over a 15-minute observation window compared to other pumps (1 IU/h): ±1.02% (JP) vs ±1.60% (AN), ±1.66% (AC), ±2.22% (MP), and ±4.63% (OP), P < .0001. But there was no difference over 24 hours. At 0.5 IU/h, the JP was able to detect an occlusion earlier than other pumps: 21 (19; 25) minutes vs 90 (85; 95), 58 (42; 74), and 143 (132; 218) minutes (AN, AC, MP), P < .05 vs AN and MP. In patients, the 24-hour flow error was not significantly different between the JP and usual pumps (–2.2 ± 5.6% vs –0.37 ± 4.0%, P = .25). The JP was found to be easier to wear than conventional pumps. Conclusions: The JP is more precise over a short time period, more sensitive to catheter occlusion, well accepted by patients, and consequently, of potential interest for a closed-loop insulin delivery system.

12 January 2016 in Obesity Surgery
Verified
Journal Article
Closed access
PDF file
CBCamille Bonis
Camille Bonis
FLFrançoise Lorenzini
Françoise Lorenzini
MBMonelle Bertrand
Monelle Bertrand
OPOlivier Parant
Olivier Parant
PGPierre Gourdy
Pierre Gourdy
HHHélène Hanaire
Hélène Hanaire

16 October 2019 in Diabetes, Obesity and Metabolism
Verified
Journal Article
Closed access
PDF file
HHHélène Hanaire
Hélène Hanaire
SFSylvia Franc
Sylvia Franc
SBSophie Borot
Sophie Borot
APAlfred Penfornis
Alfred Penfornis
PBPierre‐Yves Benhamou
Pierre‐Yves Benhamou
YRYves Reznik
Yves Reznik