TMThe Bone Defect Study Group Fernandez Francis PhD Rajagopal Karthikeyan MSc Biotechnology Mathews Vikram DM Balakumar B MS Ortho Dinesh Vivek Dutt MS Ortho Chilbule Sanjay Kashinath MS Ortho Gibikote Sridhar DNB Srivastava Alok MD
The Bone Defect Study Group Fernandez Francis PhD Rajagopal Karthikeyan MSc Biotechnology Mathews Vikram DM Balakumar B MS Ortho Dinesh Vivek Dutt MS Ortho Chilbule Sanjay Kashinath MS Ortho Gibikote Sridhar DNB Srivastava Alok MD
+1
Case: An 11-year-old child who presented with a postseptic gap nonunion of 4 cm in the proximal humerus was treated with a customized hydroxyapatite-tricalcium phosphate-tricalcium silicate composite (HASi) scaffold loaded with culture-expanded autologous bone marrow–derived mesenchymal stem cells (MSCs) primed into osteogenic lineage. Union occurred at 3 months, and at 3 years, the child had improved joint mobility, with radiographic and computed tomographic imaging evidence of incorporation of the graft. Conclusions: This case demonstrated the feasibility of MSC directed into osteogenic lineage on HASi to repair a long bone defect owing to postseptic osteomyelitis, a condition notorious for a high failure rate.
Study Design: Basic study.Purpose: This study aimed to utilize finite element (FE) analysis and design of experiment (DoE) techniques to propose and optimize a novel pedicle screw design and compare its pull-out force with that of a control device.Overview of Literature: Pedicle screw-based fixation is the gold-standard treatment for spine diseases, particularly in fusion procedures. However, pedicle screw loosening and breakage still occur in osteoporotic and non-osteoporotic patients. This research investigates screw design modifications to enhance screw-bone interface strength and reduce the likelihood of loosening.Methods: We conceptualized a novel pedicle screw considering vertebral bone morphology and strength differences. A validated FE model was developed and used in conjunction with DoE to determine the screw՚s optimum geometrical parameters. The FE model was validated through simulation and laboratory experiments using the control device. The optimized thread profiles for cortical bone and cancellous bone were determined, with pull-out force as the primary factor for screw design evaluation.Results: FE analysis results for the control device closely matched experimental results, with less than 5% difference. The chosen unique pitch/depth ratio showed maximum pull-out force for cortical bone, while DoE enabled the optimization of design parameters for cancellous bone. The optimized pedicle screw exhibited a 15% increase in pull-out force compared to the control device.Conclusions: The study proposes a novel pedicle screw design with better pull-out strength than the control device. Combining FE analysis with DoE is an effective approach for screw design optimization, reducing the need for extensive prototyping tests. A two-variable analysis suffices for optimizing cortical bone design parameters, while a multi-variable analysis is more effective for optimizing cancellous bone design parameters.