Kevin Stroek

Kevin Stroek

Auto-generated profile, based on publicly available information

Kevin Stroek

Endocrine Laboratory, Department of Clinical Chemistry, Amsterdam Gastroenterology, Endocrinology & Metabolism, Amsterdam UMC, University of Amsterdam, 1105AZ Amsterdam, The Netherlands

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 June 2021 in The Journal of Clinical Endocrinology & Metabolism
Verified
Journal Article
Closed access
PDF file
KSKevin Stroek
Kevin Stroek
ARAn Ruiter
An Ruiter
ALAnnelieke van der Linde
Annelieke van der Linde
MAMariette Ackermans
Mariette Ackermans
MBMarelle J Bouva
Marelle J Bouva
ABAnita Boelen
Anita Boelen
Context: Newborn screening (NBS) for classic congenital adrenal hyperplasia (CAH) consists of 17-hydroxyprogesterone (17-OHP) measurement with gestational age–adjusted cutoffs. A second heel puncture (HP) is performed in newborns with inconclusive results to reduce false positives. Objective: We assessed the accuracy and turnaround time of the current CAH NBS algorithm in comparison with alternative algorithms by performing a second-tier 21-deoxycortisol (21-DF) pilot study. Methods: Dried blood spots (DBS) of newborns with inconclusive and positive 17-OHP (immunoassay) first HP results were sent from regional NBS laboratories to the Amsterdam UMC Endocrine Laboratory. In 2017-2019, 21-DF concentrations were analyzed by LC-MS/MS in parallel with routine NBS. Diagnoses were confirmed by mutation analysis. Results: A total of 328 DBS were analyzed; 37 newborns had confirmed classic CAH, 33 were false-positive and 258 were categorized as negative in the second HP following the current algorithm. With second-tier testing, all 37 confirmed CAH had elevated 21-DF, while all 33 false positives and 253/258 second-HP negatives had undetectable 21-DF. The elevated 21-DF of the other 5 newborns may be NBS false negatives or second-tier false positives. Adding the second-tier results to inconclusive first HPs reduced the number of false positives to 11 and prevented all 286 second HPs. Adding the second tier to both positive and inconclusive first HPs eliminated all false positives but delayed referral for 31 CAH patients (1-4 days). Conclusion: Application of the second-tier 21-DF measurement to inconclusive first HPs improved our CAH NBS by reducing false positives, abolishing the second HP, and thereby shortening referral time.

13 May 2020 in JIMD Reports
Verified
Journal Article
Open access
PDF file
KSKevin Stroek
Kevin Stroek
ABAnita Boelen
Anita Boelen
MBMarelle J. Bouva
Marelle J. Bouva
MVMonique De Sain‐Van der Velden
Monique De Sain‐Van der Velden
PSPeter C. J. I. Schielen
Peter C. J. I. Schielen
ABAnnet Bosch
Annet Bosch
Maple syrup urine disease (MSUD) leads to severe neurological deterioration unless diagnosed early and treated immediately. We have evaluated the effectiveness of 11 years of MSUD newborn screening (NBS) in the Netherlands (screening >72 hours, referral if both total leucine (Xle) and valine ≥400 μmol/L blood) and have explored possibilities for improvement by combining our data with a systematic literature review and data from Collaborative Laboratory Integrated Reports (CLIR). Dutch MSUD NBS characteristics and accuracy were determined. The hypothetical referral numbers in the Dutch population of additional screening markers suggested by CLIR were calculated. In a systematic review, articles reporting NBS leucine concentrations of confirmed patients were included. Our data showed that NBS of 1 963 465 newborns identified 4 MSUD patients and led to 118 false‐positive referrals (PPV 3.28%; incidence 1:491 000 newborns). In literature, leucine is the preferred NBS parameter. Total leucine (Xle) concentrations (mass‐spectrometry) of 53 detected and 8 false‐negative patients (sampling age within 25 hours in 3 patients) reported in literature ranged from 288 to 3376 (median 900) and 42 to 325 (median 209) μmol/L blood respectively. CLIR showed increasing Xle concentrations with sampling age and early NBS sampling and milder variant MSUD phenotypes with (nearly) normal biochemical profiles are causes of false‐negative NBS results. We evaluated the effect of additional screening markers and established the Xle/phenylalanine ratio as a promising additional marker ratio for increasing the PPV, while maintaining high sensitivity in the Dutch MSUD NBS.

5 March 2021 in European Thyroid Journal
Verified
Journal Article
Open access
PDF file
KSKevin Stroek
Kevin Stroek
AHAnnemieke C. Heijboer
Annemieke C. Heijboer
MVMarja van Veen-Sijne
Marja van Veen-Sijne
ABAnnet M. Bosch
Annet M. Bosch
CPCatharina P.B. van der Ploeg
Catharina P.B. van der Ploeg
ABAnita Boelen
Anita Boelen
Introduction: Newborn screening (NBS) for congenital hypothyroidism (CH) in the Netherlands consists of thyroxine (T4), thyroid-stimulating hormone (TSH), and T4-binding globulin (TBG) measurements to detect thyroidal CH and central CH (CH-C). CH-C is detected by T4 or a calculated T4/TBG ratio, which serves as an indirect measure of free T4. TSH and TBG are only measured in the lowest 20 and 5% of daily T4 values, respectively. A recent evaluation of the Dutch NBS for CH showed that the T4 and T4/TBG ratio contribute to the detection of CH-C but also lead to a low positive predictive value (PPV). Dried blood spot (DBS) reference intervals (RIs) are currently unknown and may contribute to improvement of our NBS algorithm. Materials and Methods: RIs of T4, TSH, TBG, and the T4/TBG ratio were determined according to Clinical & Laboratory Standards Institute guidelines in heel puncture cards from routine NBS in both sexes and at the common NBS sampling ages. Scatter plots were used to compare the healthy reference population to previously published data of CH-C patients and false positives. Results: Analyses of 1,670 heel puncture cards showed small differences between subgroups and led to the formulation of total sample DBS RIs for T4 (56–118 nmol/L), TSH (20). 46% of false-positive referrals based on T4 alone had a TBG below the RI, indicating preventable referral due to partial TBG deficiency. One case of CH-C also had partial TBG deficiency (TBG 59 and T4 12 nmol/L blood). Discussion/Conclusion: Established DBS RIs provided possibilities to improve the PPV of the Dutch CH NBS algorithm. We conclude that by taking partial TBG deficiency into account, approximately half of T4 false-positive referrals may be prevented while maintaining NBS sensitivity at the current level.